Tripp Lite 93-2007 (200106010) Owner's Manual

Manual is about: Alternative Power Sources (230V, 50 Hz)

Summary of 93-2007 (200106010)

  • Page 1

    Owner’s manual 1111 w. 35th street chicago, il 60609 usa customer support: (773) 869-1234 • www.Tripplite.Com introduction 2 important safety instructions 4 configuration & connection 5 features 11 maintenance and service 14 powerverter ® is a registered trademark of tripp lite. All rights reserved....

  • Page 2: Introduction

    2 introduction congratulations! You’ve purchased the most advanced, feature-rich integrated inverter and battery charger on the market. Your aps provides your equipment with utility-supplied ac power when it is available, and during blackouts, overvoltages and brownouts, your aps automatically switc...

  • Page 3: 3-Stage Battery Charger

    3-stage battery charger your aps recharges your battery faster than conventional chargers because its three-stage charger profile (bulk, absorption and float) are optimized, regardless of the type of battery you use (wet or gel).* in addition, the advanced charging system protects against over-charg...

  • Page 4: Save These Instructions

    4 important safety instructions save these instructions this manual contains important instructions and warnings that should be followed during the installation, operation and storage of all tripp lite aps systems. Aps location warnings • install your aps indoors, away from excess moisture or heat, ...

  • Page 5: Configuration

    5 configuration dip switch group a (all models) battery type / voltage point using a small tool, set the 4 “battery type / voltage point” configuration dip switches, group a (located on the front panel of your aps; see diagram 1, p. 36) to select battery type and set the voltage range outside of whi...

  • Page 6: Dip Switch Group B

    6 dip switch group b (available on select models) load sharing/equalize battery charge using a small tool, set the “load sharing” configuration dip switches, #1 and #2 of group b (located on the front panel of your aps; see diagram 1, p. 36). Dip switch #3, group b should be kept in the “up” positio...

  • Page 7: • Equalize Battery Charge

    7 • equalize battery charge (dip switch #3, group b) this dip switch is momentarily engaged to begin the process of equalizing the internal resistance of your battery’s cells. This can extend the useful life of certain types of batteries; consult with your battery's manufacturer to determine if your...

  • Page 8: Mounting

    8 mounting (optional) (see diagram 2, p. 36) battery selection select a battery or system of batteries that will provide your aps with proper dc voltage and an adequate amp hour capacity.* select ‘deep-cycle’ batteries to enjoy optimum performance from your aps. Batteries of either wet-cell (vented)...

  • Page 9: Battery Connection

    9 battery connection 1. Connect your aps’s positive dc terminal directly to a fuse. Tripp lite recommends that you install a recognized component fuse block and fuse within 18 inches of the battery. The fuse's rating must equal or exceed the minimum dc fuse rating listed in your aps model’s specific...

  • Page 10: Battery Connection

    10 aps systems must be connected to a grounded, permanent wiring system. For most installations, the negative battery conductor must be bonded to the grounding system at one (and only one) point in the system. All installations must comply with national and local codes and ordinances. When figuring ...

  • Page 11: Ac Connection

    11 ac connection continued simply plug your equipment into the unit’s ac receptacles. If adapters must be used, choose adapters that provide a connection to ground. • switch to “auto/remote” when you are using connected equipment. Advantage: uninterruptible power supply. Provides battery backup powe...

  • Page 12

    12 4. “line” (all models): this green light will turn continuously on whenever connected equipment is receiving utility-supplied ac power and your aps is set to “auto/remote”, meaning that it will provide battery backup if utility power fails. It will flash intermittently when connected equipment is...

  • Page 13

    13 9. Dc input terminals (all models): the terminals’ lug screws secure the wires leading from your external battery or battery system. Your battery or battery system must provide your aps with proper dc voltage and your equipment with an adequate amp hour capacity. See battery selection section, pg...

  • Page 14: Limited Warranty

    14 limited warranty maintenance & service your aps model requires no maintenance but should be kept dry at all times. Periodically check all cable connections both at the unit and at the battery. Clean and tighten connections as necessary. If returning your aps to tripp lite, please pack the aps car...

  • Page 15: Troubleshooting

    15 try these remedies for common aps problems before calling for help. Call tripp lite customer service at (773) 869-1234 before returning your aps for service. Symptom problems corrections aps does not provide aps not properly connected to connect aps to utility power. Ac output (ac input present) ...

  • Page 16: Specifications

    16 specifications (corded models) corded models: apsint1012 weight: 11.9 kg inverter continuous power (@ 20° c): 1000 w surge power (5 seconds): 2000 w efficiency (full load): 88% minimum dc fuse rating: 170a dc input current @ nominal v dc full load 95a no load 2.6a* nominal input volts: 12 vdc dc ...

  • Page 17: Specifications

    17 specifications (hardwired models) hardwired models: apsint1524 apsint2012 weight: 12.7 kg 17.1 kg inverter continuous power (@ 20° c): 1500 w 2000 w surge power (5 seconds): 3000 w 4000 w efficiency (full load): 89% 87% minimum dc fuse rating: 90a 370a dc input current @ nominal v dc full load 70...

  • Page 18: Diagrams/esquemas

    36 output/neutra output/hot ground input/neutra input/hot “for use with copper wire only” diagrams/esquemas see “configuration”, pg. 5. 1.1 is dip switch group a. 1.2 is dip switch group b. Refiérase a la sección “configuración”, página 22. 1.1 representa el grupo a de interruptores dip. 1.2 represe...

  • Page 19: Diagrams/esquemas

    37 x/2 volts x/2 volts aps see battery connection, pg. 9. 4.1 is the fuse. X = your aps’s inverter's nominal input voltage. (see specs.) refiérase a la sección “conexión de baterías”, página 26. 4.1 representa el fusible. X = el voltaje nominal de entrada del inversor del aps. (vea las especificacio...

  • Page 20: Diagrams/esquemas

    38 aps 12v 12v basic 12vdc vehicular battery connection. See pg. 9. 7.1 is the alternator. 7.2 is the vehicle battery ground. 7.3 is the vehicle battery. 7.4 is the fuse. Conexión básica de baterías de 12v de cd en vehículos. Vea página 27. 7.1 representa el alternador. 7.2 representa la conexión a ...

  • Page 21: Diagrams/esquemas

    39 1. Operating mode switch (all models) 2. Dip switch group a (all models) 3. Dip switch group b (select models only) 4. “line” (all models) 5. “inv” (inverting—all models) 6. “load” (all models) 8. “battery hi/med/lo” (all models) 9. Dc input terminals (all models) 10. Ac receptacles (corded model...

  • Page 22: Diagrams/esquemas

    40 output/neutra output/hot ground input/neutra input/hot “for use with copper wire only” diagrams/esquemas 9b 1. Operating mode switch (all models) 2. Dip switch group a (all models) 3. Dip switch group b (select models only) 4. “line” (all models) 5. “inv” (inverting—all models) 6. “load” (all mod...