Tripp Lite PowerVerter 93-1911 Owner's Manual

Manual is about: Alternative Power Sources (120V, 60 Hz)

Summary of PowerVerter 93-1911

  • Page 1

    Copyright © 2001 tripp lite. All rights reserved. 1111 w. 35th street chicago, il 60609 usa customer support: (773) 869-1234 www.Tripplite.Com configuration & connection: p. 5-10 features: p. 10 - 11 warranty: p. 12 troubleshooting: p. 13 safety: p. 4 introduction: p. 2 - 3 maintenance & service: p....

  • Page 2: Introduction

    2 introduction congratulations! You’ve purchased the most advanced, feature-rich integrated inverter/battery charger on the market. Your aps provides your equipment with utility-supplied ac power when it is available, and during blackouts, overvoltages and brownouts, your aps automatically switches ...

  • Page 3: Advanced, 3-Stage

    3 advanced, 3-stage battery charger your aps recharges your battery faster than conventional chargers because its three-stage charger pro- file (bulk, absorption and float) are optimized, regardless of the type of battery you use (wet or gel).* in addi- tion, the advanced charging system protects ag...

  • Page 4: Safety

    4 safety this manual contains important instructions and warnings that should be followed during the installation, operation and storage of all tripp lite aps systems. Aps location warnings • install your aps indoors, away from excess moisture or heat, dust or direct sunlight. • your aps is not wate...

  • Page 5: Configuration

    4 4 3 3 2 2 1 1 5 configuration configuration dip switch settings dip switch group a (all models) battery type / voltage point using a small tool, set the 4 “battery type / voltage point” configuration dip switches, group a (located on the front panel of your aps; see diagram 1, p. 32) to select bat...

  • Page 6: • Load Sharing

    6 • load sharing (dip switches #1, group b & #2, group b) your aps features a high-output battery charger that can draw a significant amount of power from your line power source when charging at its maximum rate. If an aps is supplying its full ac power rating to its connected load at the same time ...

  • Page 7: Battery Selection

    7 • limit battery charger (aps 1012 and aps 2012 only) (dip switch #4, group b) to prevent overheating smaller batteries, the charger on these ups systems is initially set to deliver only a fraction of its maximum power rating to connected batteries. If you are using either of these aps systems with...

  • Page 8: Mounting (Optional*)

    8 mounting (optional*) (see diagram 2, p. 32). User must supply all fasteners and brackets and verify their suitability for use with the intended mounting surface. Turn your aps powerverter and connected equipment off before mounting. • install two 8 mm (1/4 in.) fasteners (a) into a rigid horizonta...

  • Page 9: Ac Connection

    9 vehicular battery connection. Choose the basic connection if you are running light hand tools or other small appliances for a brief period of time (see diagram 7, p. 34) . Choose the advanced connection if you are using your aps to power heavy loads for extended periods of time (see diagram 8, p. ...

  • Page 10: Set Operating Mode Switch

    10 set operating mode switch continued • switch to “charge only” when you are not using connected equipment. (warning! Aps will not provide battery backup!) advantages: a) continues to charge battery when power is present, and b) turns off the aps’s inverter, preventing battery drain during blackout...

  • Page 11: Other Features

    11 8. “battery hi/med/lo” (all models) these three lights will turn on in several sequences to show the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions: battery charge indication (approximate) indicator capacity green 91% - full green & y...

  • Page 12: Limited Warranty

    12 limited warranty tripp lite warrants its products to be free from defects in materials and workmanship for a period of one year (domestic) or 120 days (export) from the date of initial purchase. Tripp lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) ...

  • Page 13: Troubleshooting

    13 try these remedies for common aps problems before calling for help. Call tripp lite customer service at (773) 869-1234 before returning your aps for service. Symptom problems corrections aps does not provide aps not properly connected to connect aps to utility power. Ac output (ac input present) ...

  • Page 14: Specifications

    14 specifications (corded models) corded models: aps 1012 aps 1024 weight: 26.4 lbs. 26.4 lbs. Inverter continuous power (@ 20° c): 900 w 1000 w surge power (5 seconds): 1800 w 2000 w efficiency (full load): 90% 90% minimum dc fuse rating: 225a 125a dc input current @ nominal v dc full load 95 a 47 ...

  • Page 15: Specifications

    15 specifications (hardwired models) hardwired models: aps 2012 aps2424 weight: 38.0 lbs. 41.0 lbs. Inverter continuous power (@ 20° c): 2000 w 2400 w surge power (5 seconds): 4000 w 4800 w efficiency (full load): 90% 90% minimum dc fuse rating: 500a 300a dc input current @ nominal v dc full load 19...

  • Page 16: Diagrams/esquemas

    32 2 diagrams/esquemas 3 1 see “configuration”, pg. 5. 1.1 is dip switch group a. 1.2 is dip switch group b. Refiérase a la sección “configuración”, página 20. 1.1 representa el grupo a de interruptores dip. 1.2 representa el grupo b de interruptores dip see hardwire electrical connections, pg. 9. 3...

  • Page 17

    33 4 5 6 x/2 volts x/2 volts 6.1 x volts x volts x volts x volts 5.1 see battery connection, pg.8. 4.1 is the fuse. X = your aps's inverter's nominal input voltage. (see specs.) refiérase a la sección “conexión de baterías”, página 23. 4.1 representa el fusible. X = el voltaje nominal de entrada del...

  • Page 18

    34 7 7.4 7.1 7.3 12v 8.6 8.1 8.3 8.4 12v 8.2 8.3 8.5 12v 8 7.2 basic 12vdc vehicular battery connection. See pg.8. 7.1 is the alternator. 7.2 is the vehicle battery ground. 7.3 is the vehicle battery. 7.4 is the fuse. Conexión básica de baterías de 12v de cd en vehículos. Vea página 23. 7.1 represen...

  • Page 19

    35 1. Interruptor “operating mode” (modo de operación) 2. Grupo a de interruptores dip (todos los modelos) 3. Grupo b de interruptores dip (modelos selectos únicamente) 4. “line” (línea) (todos los modelos) 5. “inv” (inversor ) (todos los modelos) 6. “load” (carga conectada) 7. “cut/boost” (disminuy...

  • Page 20

    36 93-1911 (200103046) 1111 w. 35th street chicago, il 60609 usa customer support: (773) 869-1234 www.Tripplite.Com 200103046 120v aps mv-cabineten-sp 93-1911.Qxd 7/2/01 10:18 am page 36.