U-Line 2224BEV User Manual & Service Manual

Other manuals for 2224BEV: User Manual, User Manual, User Manual
Manual is about: 2000 Series 24" Beverage Center

Summary of 2224BEV

  • Page 1

    User guide & service manual safety • installation & integration • operating instructions • maintenance • service 2000 series • 2224bev • 24" beverage center safety • installation & integration • operating instructions • maintenance • service contents intro safety safety and warning right product. Ri...

  • Page 2

    Disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation anti-tip bracket general installation integrated grille / plinth dimensions grille / plinth installation door swing door stop door adjust wood trim finishing opera...

  • Page 3

    User guide u-line.Com use. U-line’s complete product collection includes wine captain ® models, beverage centers, clear ice machines, crescent ice makers, glass & solid door refrigerators, drawer models, freezers, combo ® models, and more. U-line has captivated those with an appreciation for the fin...

  • Page 4

    U-line.Com user guide safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precau...

  • Page 5

    User guide u-line.Com disposal and recycling danger risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all fede...

  • Page 6

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed ...

  • Page 7

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com electrical warning shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round g...

  • Page 8

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com electrical 1 cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space for top...

  • Page 9

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com cutout dimensions 1 product dimensions.

  • Page 10

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com product dimensions 1 side-by-side installation other site requirements side-by-side installation units must operate from separate, properly grounded electrical receptacles placed according to e...

  • Page 11

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com side-by-side installation 1 anti-tip bracket caution the anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front ...

  • Page 12

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com anti-tip bracket 1 general installation 3. Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level. Installation tip if the room floor is higher th...

  • Page 13

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com 1. Use the dimensions provided in the diagram to cut and shape your integrated grille (plinth strip/base fascia) panel. Recommended panel thickness is between 1/4" (6 mm) and 3/8" (9 mm). 2. Fi...

  • Page 14

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com grille - plinth installation removing and installing grille (plinth strip/base fascia) warning disconnect electric power to the unit before removing the grille (plinth strip/base fascia). When ...

  • Page 15

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com door swing for integrated models that are installed adjacent to a wall, 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space fo...

  • Page 16

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com.

  • Page 17

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com integrated stainless.

  • Page 18

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com door swing 1 door stop your u-line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90° follow...

  • Page 19

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com door stop 1 door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or...

  • Page 20

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com b y l i f t i n g t o p a n d b o t t o m f l a p s a n d s l i d e i n w a r d s . R e p e a t o n b o t t o m h i n g e . Door adjustments 1.

  • Page 21

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com 3. Using t-25 torx bit loosen screw #1 and remove screw #2 on top and bottom hinge. Slide and remove the door from unit. Completely remove screw #1 on top and bottom. 4. Remove caps from screw ...

  • Page 22

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com door adjustments 2 wood trim finishing the wine rack fronts are solid natural beech wood. They are factory coated with a clear vinyl sealer, which will sufficiently protect the wood in normal u...

  • Page 23

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com wood trim finishing 1.

  • Page 24

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with product. When p...

  • Page 25

    Safety • installation & integration • user guide u-line.Com first use 1 operating instructions • maintenance • service control operation control function guide function command display/options on/off press and release unit will immediately turn on or off. Toggle lights press and release to leave int...

  • Page 26

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com control operation 1 sabbath mode disables system responses to user initiated activities and all external functions, including lighting, display and audible alarms. The unit will still maintain ...

  • Page 27

    Safety • installation & integration • user guide u-line.Com sabbath mode 1.

  • Page 28

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille, internal fans or vents at any time, or the unit will not...

  • Page 29

    Safety • installation & integration • operating instructions • maintenance • service u-line wine guide 1 user guide u-line.Com airflow and product loading 1 u-line wine guide looking behind the label to most, wine is a delicious mystery. We purchase it, uncork it, and savor its taste and beauty. But...

  • Page 30

    Safety • installation & integration • operating instructions • maintenance • service u-line wine guide 2 user guide u-line.Com pork, veal, lamb and poultry light-bodied red wines fruit sweet white and sparkling wines a toast to wine truths like the grapes themselves, many wine myths have been cultiv...

  • Page 31

    Safety • installation & integration • operating instructions • maintenance • service u-line wine guide 3 user guide u-line.Com temperature: the most important element about storage temperature is stability. If wine is kept in a stable environment between 40°f (7°c) and 65°f (21°c), it will remain so...

  • Page 32

    Safety • installation & integration • operating instructions • maintenance • service u-line wine guide 4 user guide u-line.Com the right temperature for wine temperature wines approximately 60°f (15°c) red 50°f - 55°f (10°c -12°c) white approximately 45°f (7°c) sparkling wine captain ® models - a to...

  • Page 33

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com recommended wine storage specially designed horizontal wine racks properly position the bottles so the wine remains in contact with the cork, which ensures the cork does not become dry. U-line ...

  • Page 34

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com recommended wine storage 1 interior shelves removing and installing glass shelves adjusting interior shelves models equipped with glass shelves have an adjustable mounting system. To adjust or ...

  • Page 35

    User guide u-line.Com cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your stainless unit looking new by cleaning with a good quality all-in-one stainless steel cleaner an...

  • Page 36

    User guide u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the ...

  • Page 37

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com cleaning 2 cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the condenser whe...

  • Page 38

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com wine rack installation to remove wine racks for cleaning: 1. Remove any bottles stored on the rack. 2. Grasp the end of the rack and gently slide it out until it stops. 3. The release levers ar...

  • Page 39

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com 1. Remove all consumable content from the unit. 2. Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service. 3. If ice is on the evaporat...

  • Page 40

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the control. If the probl...

  • Page 41

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com digital display shows er or e followed by a number. E3 indicates the door may be opened too long. Ensure the door is closing properly. For other error codes contact u-line customer service. Tro...

  • Page 42

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com troubleshooting 2 u-line corporation (u-line) limited warranty one year limited warranty for one year from the date of original purchase, this u-line product warranty covers all parts and labor...

  • Page 44

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com wire diagram 1 product liability field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, ...

  • Page 45

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com product liability 1 warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent...

  • Page 46

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com warranty claims 1.

  • Page 48

    Safety • installation & integration • operating instructions • maintenance • service u-line.Com ordering replacement parts if you have a purchasing account, please utilize our service website to order parts. Orders may also be placed by fax or phone. See our contact information below: www.U-lineserv...

  • Page 49

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com ordering replacement parts 1 user guide system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube ...

  • Page 50

    Safety • installation & integration • operating instructions • maintenance • service u-line.Com to ensure the windings are not shorted, check the s and r to ground. Emx20clc refrigerant r600a voltage 115 - 127 vac frequency 60 hz run cap 12μf/165 vac start winding 6.7 ohm at 77°f run winding 12.6 oh...

  • Page 51

    Safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended 1 user guide u-line.Com troubleshooting - extended caution never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected from the unit. S...

  • Page 52

    Safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended 2 user guide u-line.Com test overload and relay, replace as needed. Compressor operating - no cooling refer to system diagnosis guide. Evaporator fan not operating use #19, component testi...

  • Page 53

    Safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended 3 user guide u-line.Com testing the main control if the main control is suspected of being faulty, the following procedure should be performed to verify main control for functionality. Rel...

  • Page 54

    Safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended 4 user guide u-line.Com (switch closed) magnet away from switch ) door open ( switch open ( ).

  • Page 55

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 1 user guide u-line.Com control operation - service ui button layout 1 2 3 4 5 6 7 1. Hidden button -accesses service menu -no led directly above. All leds turn on with button activation ...

  • Page 56

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 2 user guide u-line.Com control function quick guide function command display/options on/off press and release unit will immediately turn on or off toggle lights press and release to leav...

  • Page 57

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 3 user guide u-line.Com 7 adjust thermistor #3 offset 8 adjust thermistor #4 offset 9 view thermistor #2 set point no offsets 10 view thermistor #3 set point no offsets 11 view thermistor...

  • Page 58

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 4 user guide u-line.Com e4: thermistor 4 open (does not apply to this model). E5: thermistor 1 shorted. E6: thermistor 2 shorted. E7: thermistor 3 shorted. E8: thermistor 4 shorted (does ...

  • Page 59

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 5 user guide u-line.Com 1215r 07 2218r 05 2245r 55 1215wc 12 2218rgl 04 2245dc 54 1224bev 13 2218wc 06 2245wc 56 1224dwr 08 2224bev 00 2260dc 50 1224r 14 2224r 02 2260r 52 1224rf 09 2224r...

  • Page 60

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 6 user guide u-line.Com.

  • Page 61

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 7 user guide u-line.Com.

  • Page 62

    Safety • installation & integration • operating instructions • maintenance • service control operation - service 8 user guide u-line.Com.

  • Page 63

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatures. If a faul...

  • Page 64

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com if the thermistor fails the unit will operate normally. Thermistor 1 thermistor resistance data temp (f) temp (c) nominal resistance (ohms)* -40 -40 169157 -31 -35 121795 -22 -30 88766 -13 -25 ...

  • Page 65

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com thermistor 2 defrost the models below have automatic or frost free design and do not require manual defrosting under normal conditions. Defrost settings base model variant(s) compressor run tim...

  • Page 66

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com cycle. Fan delay times can be modified through the service menu. Evaporator fan operation is also determined by door switch state. If the door switch circuit opens, the fan will stop. When the ...

  • Page 67

    Safety • installation & integration • operating instructions • maintenance • service user guide u-line.Com 14.Remove and replace fan. Take special care to properly route fan wire. Notice fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting locatio...