  • Page 1

    User guide safety • installation & integration • operating instructions • maintenance • service 2000 series • 2245rdc • 45 cm drinks cabinet right product. Right place. Right temperature. Since 1962..

  • Page 2

    User guide u-line.Com contents safety • installation & integration • operating instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation anti-tip bracke...

  • Page 3

    User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...

  • Page 4

    User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Safety alert definitions throughout this guide are safety i...

  • Page 5

    User guide safety and warning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service caution ! Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. If your model requires defrosting, do not use medical devices ...

  • Page 6

    User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...

  • Page 7

    User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...

  • Page 8

    User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...

  • Page 9

    User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...

  • Page 10

    User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 33-11/16" to 34-11/16" (856 mm to 881 mm) 23-7/16" (590 mm)* 17-3/4" (450 mm) 3-5/16" (84 mm) *includes 3/4" (20 mm) integrated panel.

  • Page 11

    User guide side-by-side installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-by-side installation other site requirements side-by-side installation units must operate from separate, properly grounded electrical receptacles placed accordi...

  • Page 12

    User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...

  • Page 13

    User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...

  • Page 14

    User guide integrated panel dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel dimensions integrated frame notice due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is...

  • Page 15

    User guide integrated panel dimensions 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated frame the following procedure is designed to provide a finished, handleless frame for an 18" (45 mm) door that seamlessly integrates with its...

  • Page 16

    User guide integrated panel dimensions 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated frame dimensions 3/4" (20 mm) 28-13/16" (732 mm) 2-3/4" (70 mm) 2-3/4" 70 mm r 5/8" (r 16 mm) 1/8" (3 mm) 1/4" (6 mm) wooden insert notch dep...

  • Page 17

    User guide integrated panel dimensions 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated frame notice due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is designed to provid...

  • Page 18

    User guide integrated panel dimensions 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3-5/16" (89 mm) to 4-5/16" (114 mm) u-line unit u-line unit integrated panel integrated panel/integrated frame front side front side 3-5/16" (89 mm) to 4-5/16" (11...

  • Page 19

    User guide integrated panel dimensions 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated frame dimensions notice the minimum border thickness for a 30" (762 mm) tall integrated frame is 2-3/4" (70 mm). The top/bottom border of the f...

  • Page 20

    User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...

  • Page 21

    User guide integrated panel installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel installation 1. Fully open door. 2. Starting at corner, pull gasket away from door. 3. Continue to pull gasket free from gasket channel. 4. Upon...

  • Page 22

    User guide integrated panel installation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 11.Remove clamps from door. Notice if panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tight...

  • Page 23

    User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electric power to the unit before removing the grille ...

  • Page 24

    User guide door swing 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door swing for models that are installed adjacent to a wall, 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space ...

  • Page 25

    User guide door stop 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door stop your u-line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90° follow ...

  • Page 26

    User guide door adjustments 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool prope...

  • Page 27

    Door adjustments 2 user guide safety • installation & integration • operating instructions • maintenance • service u-line.Com 3. Using t-25 torx bit loosen screw #1 and remove screw #2 on top and bottom hinge. Slide and remove the door from unit. Completely remove screw #1 on top and bottom. 4. Remo...

  • Page 28

    User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with pro...

  • Page 29

    User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation door alert notification when the door is left open for more than 5 minutes: • an audible tone will sound for several seconds every minute. • the alert led ...

  • Page 30

    User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode this unit is star-k certified and offers a sabbath mode. Sabbath mode disables system responses to user initiated activities and all external functions, including ...

  • Page 31

    User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille, internal fans or vents at ...

  • Page 32

    User guide interior shelves 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service interior shelves removing and installing glass shelves adjusting interior shelves models equipped with glass shelves have an adjustable mounting system. To adjust or simply r...

  • Page 33

    User guide refrigerator bins - crisper 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service refrigerator bins - crisper refrigerator bin installation & removal refrigerator bins are easily removed for cleaning and sanitizing. To remove your bin follow the...

  • Page 34

    User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...

  • Page 35

    User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flo...

  • Page 36

    User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...

  • Page 37

    User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...

  • Page 38

    User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...

  • Page 39

    User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service checking product temperature to check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermomet...

  • Page 40

    User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty products outside the united states and canada 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in ma...

  • Page 41

    User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service installation of the product or from any other cause whatsoever, whether based on warranty (express or implied) or otherwise based on contract, tort, or any other theory of liability....

  • Page 42

    User guide wire diagram 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service wire diagram 42348_a wiring diagram power cord assembly ground: green or green w/ yellow hot: black (115v) brown (220-240v) neutral: light blue (to compressor) 1 10 neutral: whit...

  • Page 43

    User guide product liability 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product liability important note: service or repairs must not be performed on any unit suspected to be involved in a property damage situation. If a unit has been altered or...

  • Page 44

    User guide warranty claims 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent) ...

  • Page 45

    User guide ordering replacement parts 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ordering replacement parts parts may be ordered on-line, by fax or on the phone. See our contact information below: www.U-lineservice.Com (with service login) fax n...

  • Page 46

    User guide system diagnosis guide 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube evaporator watt...

  • Page 47

    User guide compressor specifications 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service compressor specifications danger ! Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when s...

  • Page 48

    User guide troubleshooting - extended 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended specific errors and issues the technically advanced diagnostic capabilities of the electronic controls utilized on the 1200 and 2200 seri...

  • Page 49

    User guide troubleshooting - extended 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service main control the main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures ...

  • Page 50

    User guide troubleshooting - extended 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrou...

  • Page 51

    User guide control operation - service 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation - service ui button layout 1. Hidden button -accesses service menu -no led directly above. Led #7 turns on with button activation. 2. Up button -...

  • Page 52

    User guide control operation - service 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 1. Viewing actual temperature in viewing temperature in these modes any offsets are taken into account. This means that if you place a thermistor in a known temper...

  • Page 53

    User guide control operation - service 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode guide number service mode menu item to navigate/access 1 view thermistor #1 cabinet temp no offsets use up/down to access and light bulb key to view 2...

  • Page 54

    User guide control operation - service 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode guide 1. Thermistor 1 — temperature this will show the pure thermistor reading with no offsets taken into account. When placed in ice water this therm...

  • Page 55

    User guide control operation - service 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service 19. Individual component toggle relay #2. ... Relay #3. Will start the ice maker module and forward it through a full harvest cycle relay #4. Will send voltage to ...

  • Page 56

    User guide control operation - service 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service model list programming the unit to correct model number • unplug unit and install new board • push and hold the hidden icon • plug the unit in • release the hidden...

  • Page 57

    User guide thermistor 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatur...

  • Page 58

    User guide defrost 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrost these units are manual defrost. To defrost unit remove ice bucket. Turn unit off. Use toweling inside to absorb water as it melts down. This will help prevent water from getti...

  • Page 59

    User guide remove fan and cover 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service remove fan and cover convection cooling this unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product...

  • Page 60

    User guide remove fan and cover 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 13.Remove the 4 screws mounting the fan shroud to the evaporator plate. 14.Remove and replace fan. Take special care to properly route fan wire. Notice fan must be orient...