- DL manuals
- U-Line
- Wine Cooler
- 3018WC
- User manual
U-Line 3018WC User manual - page 29
USER GUIDE
Interior Shelves 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION •
OPERATING INSTRUCTIONS
• MAINTENANCE • SERVICE
Interior Shelves
REMOVING AND INSTALLING GLASS SHELVES
Adjusting Interior Shelves
Models equipped with glass shelves have an adjustable
mounting system. To adjust or simply remove shelves for
cleaning, follow the instructions below.
1. Remove all product from shelf.
2. Coming from underneath the shelf, lift both the front
and rear of the glass.
3. Carefully slide shelf out of unit being careful not to
scratch the interior liner.
4. Installation is the reverse of removal.
Adjusting Shelf Height
Shelf height may be adjusted to accommodate a broad
range of product. To alter your shelf spacing follow the
instructions below.
1. Remove the 4 Shelf clips from the shelf clip holes.
2. Move shelf clips as a group to the desired shelf height.
3. Insert shelf clips into the holes of the desired shelf
height. Be certain shelf clip is fully seated into shelf clip
hole.
CAUTION
!
Clips MUST be installed with the ribbed side
down. Failure to do so may result in shelf or unit
damage.
NOTICE
All 4 shelf clips for each shelf must be installed
at the same height for shelf stability.
4. Reinstall shelf.
Cleaning Shelves
Shelves may be cleaned in a soapy warm water solution.
A general household disinfectant may be used if
necessary. Be sure to completely dry your shelf before
reinstalling.
Clip
Holes
Summary of 3018WC
Page 1
User guide safety • installation & integration • operating instructions • maintenance • service modular 3000 series • 3018rgl • 18" glass door refrigerator right product. Right place. Right temperature. Since 1962..
Page 2
User guide u-line.Com contents safety • installation & integration • operati ng instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation anti-tip brack...
Page 3
User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...
Page 4
User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...
Page 5
User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...
Page 6
User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...
Page 7
User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...
Page 8
User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...
Page 9
User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 33-11/16" to 34-11/16" (856 mm to 881 mm) 17-3/4" (450 mm) 3-5/8" to 4-5/8" (92 mm to 118 mm) not including handle 23-7/16" (590 mm).
Page 10
User guide side-by-side installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-by-side installation other site requirements side-by-side installation units must operate from separate, properly grounded electrical receptacles placed accordi...
Page 11
User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...
Page 12
User guide anti-tip bracket 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 5. Using a 3/32" drill bit, drill 3 pilot holes 5/8" (16 mm) deep into cabinetry frame using the anti-tip bracket as a template. 6. Install the 3 remaining #8x5/8" screws int...
Page 13
User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...
Page 14
User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...
Page 15
User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electrical current to the unit before removing the gri...
Page 16
User guide door swing 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door swing for integrated models that are installed adjacent to a wall, 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additi...
Page 17
User guide door stop 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door stop your u-line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90° follow ...
Page 18
User guide door adjustments 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool prope...
Page 19
User guide door adjustments 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service alignment and adjustment procedure 1. Using a t-25 torx bit, loosen each pair of torx head screws on both the upper and lower hinge plates. 2. Square and align door as necess...
Page 20
User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with pro...
Page 21
User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation control function guide function command display/options off press and hold display will count down from 5 to off. On press and release unit will come on im...
Page 22
User guide control operation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service u-select ® control digital display the 3000 series units are controlled by a feature rich, advanced oled display control unit. The control panel allows adjustment to tempera...
Page 23
User guide control operation 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service interior lighting your u-line 3000 series unit uses a state of the art led lighting system. The 3036 model dual zone’s lighting can be independently controlled or set as a g...
Page 24
User guide control operation 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service customer menu the 3000 series of u-line undercounter refrigeration appliances contains a feature rich customer menu. The customer menu allows access to a series of advanced ...
Page 25
User guide control operation 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service languages the u-line 3000 series of models supports a number of display languages including english, spanish, french and german. 1. To change display language select languag...
Page 26
User guide control operation 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service factory default factory default will restore all settings to their factory default. To access factory default: 1. Press to select “factory default”. 2. Press . To restore se...
Page 27
User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode this unit offers a sabbath mode for users who require this functionality during sabbaths. Sabbath mode disables system responses to user initiated activities and a...
Page 28
User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille, internal fans or vents at ...
Page 29
User guide interior shelves 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service interior shelves removing and installing glass shelves adjusting interior shelves models equipped with glass shelves have an adjustable mounting system. To adjust or simply r...
Page 30
User guide refrigerator bins - crisper 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service refrigerator bins - crisper refrigerator bin installation & removal refrigerator bins are easily removed for cleaning and sanitizing. To remove your bin follow the...
Page 31
User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...
Page 32
User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flo...
Page 33
User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...
Page 34
User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...
Page 35
User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...
Page 36
User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the system detec...
Page 37
User guide troubleshooting 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service 6. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small increment (see control operation). Causes which affect the intern...
Page 38
User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in materials and workmanship for a period of one ye...
Page 39
User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service of pool water, or directing a spray from a hose or similar device into and around the unit. 7. If a product defect is discovered during the applicable warranty period, you must promp...
Page 40
User guide wire diagram 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service wire diagram 42282_f wiring diagram ground: green or green w/ yellow hot: black (115v) brown (220-240v) neutral: blue (115 v) light blue (220-240v) (to compressor) 1 10 control b...
Page 41
User guide product liability 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product liability important note: service or repairs must not be performed on any unit suspected to be involved in a property damage situation. If a unit has been altered or...
Page 42
User guide warranty claims 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent) ...
Page 43
User guide ordering replacement parts 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ordering replacement parts parts may be ordered on-line, by fax or on the phone. See our contact information below: www.U-lineservice.Com (with service login) fax n...
Page 44
User guide system diagnosis guide 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube evaporator watt...
Page 45
User guide compressor specifications 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service compressor specifications danger ! Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when s...
Page 46
User guide troubleshooting - extended 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended specific errors and issues the technically advanced diagnostic capabilities of the electronic controls utilized on the 3000 series units ...
Page 47
User guide troubleshooting - extended 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service testing the main control if the main control is suspected of being faulty, the following procedure should be performed to verify main control for functionality. Rel...
Page 48
User guide troubleshooting - extended 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service fault system diagnosis guide error solution 1 solution 2 solution 3 no comm inspect customer ui and data cable (if defective replace entire door) zone t open inspec...
Page 49
User guide troubleshooting - extended 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service refrigeration system diagnosis guide thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a re...
Page 50
User guide troubleshooting - extended 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service reed switch a reed switch is used to monitor door state. When the door is closed magnetic force pulls the reed to its contact and closes the circuit which turns the...
Page 51
User guide troubleshooting - extended 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service relay toggle relay toggle is used to manually switch the state of each relay to test for proper operation. In addition to the ac relays, dc outputs may also be togg...
Page 52
User guide troubleshooting - extended 7 u-line.Com safety • installation & integration • operating instructions • maintenance • service all errors the all errors option keeps record of any system errors. When an error occurs it is recorded to all errors. The number next to the error indicates the nu...
Page 53
User guide troubleshooting - extended 8 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access relay status: 1. Press to select “relay status”. 2. Press . 3. Press and to scroll through available information. 4. Press to exit the relay status menu. ...
Page 54
User guide troubleshooting - extended 9 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the s...
Page 55
User guide control operation - service 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation - service review actual temps review error log relay status relay toggle inputs o utputs offsets self test differentials set points factory defau...
Page 56
User guide control operation - service 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service service menu in addition to a feature rich customer menu, the 3000 series also offers a service menu with the ability to fine tune and monitor unit operation. To i...
Page 57
User guide control operation - service 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access all errors follow the steps below. 1. Use down to select “all errors”. 2. Press select . 3. Use up and down to scroll through available information. To c...
Page 58
User guide control operation - service 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service relay toggle relay toggle is used to manually switch the state of each relay to test for proper operation. In addition to the ac relays, dc switches may also be to...
Page 59
User guide control operation - service 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service outputs outputs is used to monitor the state of dc outputs. To access outputs 1. Use down to select “outputs”. 2. Press select . 3. Use up and down to scroll throu...
Page 60
User guide control operation - service 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service self test is used to initiate a self diagnostic report. Any system faults will be displayed under self test. If no errors are present “no errors” will be displayed...
Page 61
User guide control operation - service 7 u-line.Com safety • installation & integration • operating instructions • maintenance • service 6. Press select to confirm setting. To exit the set points menu use up to select “return to menu” and press select to confirm. Factory default factory default will...
Page 62
User guide control operation - service 8 u-line.Com safety • installation & integration • operating instructions • maintenance • service fan delay the fan delay menu option allows the modification of fan run times during and after a cooling cycle. In order to allow time for the evaporator to properl...
Page 63
User guide control operation - service 9 u-line.Com safety • installation & integration • operating instructions • maintenance • service showroom mode showroom displays a number of features and allows the unit to be powered on without running the cooling system. To toggle showroom mode 1. Use down t...
Page 64
User guide control defaults 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control defaults * 115v models default to fahrenheit. 220-240v models default to celsius. ** offset and differential always expressed in °f. Default value fahrenheit/celsius*...
Page 65
User guide service mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode quick guide review actual temps review error log relay status relay toggle inputs outputs self test differentials factory defaults reselect model usb port showroom m...
Page 66
User guide service mode 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service service menu in addition to a feature rich customer menu, the 3000 series also offers a service menu with the ability to fine tune and monitor unit operation. To initiate the ser...
Page 67
User guide service mode 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service to clear the error log use down to select “clear errors” and press select to confirm. To exit the actual temps menu use up to select “return to menu” and press select to confirm....
Page 68
User guide service mode 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access relay toggle 1. Use down to select “relay toggle”. 2. Press select . 3. Use up and down to scroll through each relay or dc output. 4. Press select to toggle. To exit th...
Page 69
User guide service mode 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice customer care must be notified and approve of any changes to the differential before they are made. Failure to notify customer care will void the warranty. Offsets are use...
Page 70
User guide service mode 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service differentials are used to determine the maximum variation from set point and have a range of 0 through 10. The table below shows the effect of differentials on cooling cycles wit...
Page 71
User guide service mode 7 u-line.Com safety • installation & integration • operating instructions • maintenance • service 2. Press up or down to scroll through each available model. 3. Press select to confirm. To exit re-select model use up to select “return to menu” and press select to confirm. Usb...
Page 72
User guide service mode 8 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3. Press select to confirm. To exit “usb port” use up to select “return to menu” and press select to confirm. To access usb port 1. Use down to select “usb port”. 2. Press select...
Page 73
User guide service mode 9 u-line.Com safety • installation & integration • operating instructions • maintenance • service note: relay 4 will cycle with relay 6, this is considered normal. Communication data id table (sample temperatures in f) field 1 2 --- 4 5 6 7 8 9 10 id time live na --- bin temp...
Page 74
User guide thermistor 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatur...
Page 75
User guide defrost 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrost these units are frost free technology model hrs between defrost time length/ minutes stop point 2218r/wc 12 45 42 2224bev/r/wc 12 45 42 3018r/wc 12 45 40 1224dwr 12 45 42 1224...
Page 76
User guide remove fan and cover 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service remove fan and cover convection cooling this unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product...
Page 77
User guide remove fan and cover 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 13.Remove the 4 screws mounting the fan shroud to the evaporator plate. 14.Remove and replace fan. Take special care to properly route fan wire. Notice fan must be orient...