- DL manuals
- U-Line
- LCD Drawer
- 3060DWR
- User Manual
U-Line 3060DWR User Manual
Summary of 3060DWR
Page 1
User guide & service manual safety • installation & integration • operating instructions • maintenance • service modular 3000 series • 3060dwr • 60 cm drawer model right product. Right place. Right temperature. Since 1962..
Page 2
User guide u-line.Com contents safety • installation & integration • operati ng instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions anti-tip bracket general installation in...
Page 3
User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, delivering versatility ...
Page 4
User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Safety alert definitions throughout this guide are safety i...
Page 5
User guide safety and warning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service caution ! Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. If your model requires defrosting, do not use medical devices ...
Page 6
User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...
Page 7
User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...
Page 8
User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...
Page 9
User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...
Page 10
User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 23-1/4" (591 mm) 33-11/16" to 34-11/16" (856 mm to 881 mm) 23 5/8" (600 mm) *includes 3/4" (20 mm) integrated panel 3-5/8" to 4 5/8" (92 to 118 mm).
Page 11
User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...
Page 12
User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not level, remove grille...
Page 13
User guide integrated panel dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel dimensions metric measurements rounded and optimized. Standard panels notice due to differences in surrounding cabinetry the panel may not perfect...
Page 14
User guide integrated panel dimensions 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated drawer panels the following procedure is designed to provide a finished, handleless solid panel for a 24" (600 mm) drawer that seamlessly int...
Page 15
User guide integrated panel dimensions 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated panel dimensions 3/4" (20 mm) 13-13/16" (351 mm) r 5/8" (r 16 mm) 1/8" (3 mm) 1/4" (6 mm) wooden insert notch depth: 1/8" (3 mm) 2-3/8" (60 m...
Page 16
User guide integrated panel dimensions 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated panels notice due to differences in surrounding cabinetry the panel may not perfectly align with drawer. The procedure below is designed to pro...
Page 17
User guide integrated panel dimensions 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3-5/16" (89 mm) to 4-5/16" (114 mm) u-line unit u-line unit integrated panel integrated panel/integrated frame front side front side 3-5/16" (89 mm) to 4-5/16" (11...
Page 18
User guide integrated panel dimensions 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated panel dimensions top drawer bottom drawer back surface must have ample flat surface to mount overlay panel flat and without interference 23-1/2...
Page 19
User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...
Page 20
User guide integrated panel installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel installation 1. Fully open drawer. 2. Align top of panel with top edge of drawer. Center panel on drawer. Notice due to differences in floor con...
Page 21
User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electrical current to the unit before removing the gri...
Page 22
User guide drawers 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drawers checking drawer alignment the unit’s drawers are aligned at the factory before shipment. However, their alignment could have been disturbed during shipment or during overlay p...
Page 23
User guide drawers 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-to-side adjustment the drawer will need a side- to-side adjustment if, when viewed from the top, the drawer front is not square with the sides of the cabinet. This is caused by o...
Page 24
User guide drawers 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service severe adjustment: note: the slides have extra mounting holes that may be used. 1. Loosen one slide’s rear mounting screws. 2. Remove the slide’s front mounting screws. 3. Reposition ...
Page 25
User guide drawers 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service re-installation of drawer caution ! Use care when handling the drawer. Drawer edges, drawer rail and the unit’s slide may be sharp. 1. Set the drawer’s rails onto the slides. 2. Re-in...
Page 26
User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with pro...
Page 27
User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation your unit is equipped with two zones. Each zone can be set to a different mode. Control function guide function command display/options off press and hold ...
Page 28
User guide control operation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service u-select ® control digital display the 3000 series units are controlled by a feature rich, advanced oled display control unit. The control panel allows adjustment to tempera...
Page 29
User guide control operation 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service the following table lists modes which include the quick chill feature and the time which quick chill will run. To initiate quick chill: 1. Press to select the desired zone, ...
Page 30
User guide control operation 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the system det...
Page 31
User guide control operation 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service energy saver mode energy saver mode reduces overall energy consumption by altering user set point, differential, lighting and tone settings. When in energy saver mode a smal...
Page 32
User guide control operation 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service 2. Press . The current setting will begin to flash. 3. Press or to select a different level. 4. Press to confirm your choice. Fahrenheit/celsius temperature and set point in...
Page 33
User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode this unit offers a sabbath mode for users who require this functionality during sabbaths. Sabbath mode disables system responses to user initiated activities and a...
Page 34
User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille, or the unit will not perfo...
Page 35
User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...
Page 36
User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flo...
Page 37
User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...
Page 38
User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...
Page 39
User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...
Page 40
User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service checking product temperature to check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermomet...
Page 41
User guide u-line.Com safety • installation & integration • operating instructions • maintenance • service u-line corporation (u-line) limited warranty one year limited warranty for one year from the date of original purchase, this u-line product warranty covers all parts and labor to repair or repl...
Page 42
User guide wire diagram 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service wire diagram 42349_c wiring diagram 115 volt plug 220-240 volt plug ground: green or green w/ yellow hot: black (115v) brown (220-240v) neutral: white (115v) blue (220-240v) (to ...
Page 43
User guide product liability 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product liability field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process invol...
Page 44
User guide warranty claims 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent) ...
Page 45
User guide ordering replacement parts 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ordering replacement parts if you have a purchasing account, please utilize our service website to order parts. Orders may also be placed by fax or phone. See our c...
Page 46
User guide system diagnosis guide 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube evaporator watt...
Page 47
User guide compressor specifications 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service compressor specifications danger ! Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when s...
Page 48
User guide troubleshooting - extended 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended specific errors and issues the technically advanced diagnostic capabilities of the electronic controls utilized on the 3000 series units ...
Page 49
User guide troubleshooting - extended 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting guide concern potential causes suggested remedy not cooling compressor overheating verify proper air flow through condenser (refer to airflow/genera...
Page 50
User guide troubleshooting - extended 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service main control the main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures ...
Page 51
User guide troubleshooting - extended 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service other suspected main control faults if other components have been ruled out as being faulty but the unit continues to have operating issues, it is most likely due t...
Page 52
User guide troubleshooting - extended 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service fault system diagnosis guide error solution 1 solution 2 solution 3 no comm inspect customer ui and data cable (if defective replace entire door) zone t open inspec...
Page 53
User guide troubleshooting - extended 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrou...
Page 54
User guide control operation - service 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation - service actual temps all errors relay status relay toggle input status o utputs offsets self test set points mullion re-select model # factory ...
Page 55
User guide control operation - service 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service service menu in addition to a feature rich customer menu, the 3000 series also offers a service menu with the ability to fine tune and monitor unit operation. To i...
Page 56
User guide control operation - service 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access all errors follow the steps below. 1. Press to select “all errors”. 2. Press . 3. Press and to scroll through available information. To clear the error l...
Page 57
User guide control operation - service 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service 5. Press . 6. Press and to scroll through each relay and dc output. 7. Press to toggle. To exit the relay toggle menu press to select “return to menu” and press to...
Page 58
User guide control operation - service 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service offsets are used to adjust or correct thermistor readings. Offset values are added to the current thermistor reading and are then used by the control board to dete...
Page 59
User guide control operation - service 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service evap fan (excludes zwc) the evap fan option in the service menu allows servicers to change the evaporator fan runtime (in minutes) from 0 to 98 and off cycle time ...
Page 60
User guide control operation - service 7 u-line.Com safety • installation & integration • operating instructions • maintenance • service re-select model allows the units model information to be modified. Changing the units model completely reprograms available zones, relay assignments, dc output ass...
Page 61
User guide control operation - service 8 u-line.Com safety • installation & integration • operating instructions • maintenance • service the fan delay menu option allows the modification of fan run times during and after a cooling cycle. In order to allow time for the evaporator to properly cool, th...
Page 62
User guide thermistor 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatur...
Page 63
User guide thermistor 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service evaporator thermistors if an evaporator thermistor fails the unit will rely on a preset defrost timer during defrost cycles. The unit will otherwise operate normally. Refer to defr...
Page 64
User guide defrost 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrost the models below have automatic or frost free design and do not require manual defrosting under normal conditions. The defrost settings for 3000 series models are determined b...
Page 65
User guide remove fan and cover 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service remove fan and cover convection cooling this unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product...
Page 66
User guide remove fan and cover 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 12.Remove the 4 screws mounting the fan shroud to the evaporator plate. 13.Remove and replace fan. Take special care to properly route fan wire. Notice fan must be orient...