U-Line H-1075 Operating Instructions

Summary of H-1075

  • Page 1

    Page 1 of 4 0614 ih-1075 π h-1075 20" vacuum sealer 1-800-295-5510 uline.Com safety precautions to insure safe operation, the operator should be familiar with the pinch points and a possible burn hazard near the seal jaw area. Warning stickers mark the location of these hazards. Do not wear neckties...

  • Page 2

    Page 2 of 4 0614 ih-1075 important! Read this section prior to operation. Setup 1. Place the h-1075 on a flat working surface. 2. Locate the "air in" port on rear. 3. Attach clean, dry air supply using 1 / 4 " od plastic tubing (supplied with sealer). 4. Verify air pressure. Caution! Do not exceed 8...

  • Page 3: Maintenance

    Page 3 of 4 0614 ih-1075 inspections at the start of each shift or production run, inspect the seal jaw area. 1. Check the teflon ® tape covering the heating element for wrinkles, bumps or burn marks. If present, remove and reapply covering to smooth them out. For burn marks, replace with new teflon...

  • Page 4: Troubleshooting

    Page 4 of 4 0614 ih-1075 operating issue actions recommendations no green power light check main power switch. Check fuse. Is the machine operating? Has the machine’s duty cycle increased? Is power switch in the on position? Replace fuse if necessary. If yes, green lamp is out on the main power swit...