  • Page 1

    ® the built-in undercounter leader since 1962 u-line.Com install guide modular 3000 series u-3018wcol-00 u-3018wcol-01 u-3018wcs-00 u-3018wcs-01 u-3018wcs-13 u-3018wcs-15 u-3024wcol-00 u-3024wcol-01 u-3024wcs-00 u-3024wcs-01 u-3036wcwcol-00 u-3036wcwcs-00 u-3036wcwcs-13 u-3024bevol-00 u-3024bevol-01...

  • Page 2

    Safety precautions safety alert definitions ........................................................................................................................................ 1 general precautions.....................................................................................................

  • Page 3

    1 u-line 3000 series product features important important • please read all instructions before installing, operating, or servicing the appliance. • proper installation procedures must be followed when completing an installation or relocation of a unit. Consult the installation guide before any inst...

  • Page 4

    U-line inspect & plan 2 3 inspect & plan product registration you have received a carton containing your 3000 series unit with a package inside containing a use and care guide and a product registration card. Please complete and mail the product registration card or register online at www.U-lineserv...

  • Page 5

    U-line prepare site 3 your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must not be obstructed and clearance is required for an electrical connection in the ...

  • Page 6

    Product dimensions 4 5 product dimensions 3018 series 3036 series 33-11/16" to 34-11/16" 22-11/16" 17-3/4" 4-3/4" to 5-3/4" glass & solid overlay 23-7/16" 3-5/8" to 4-5/8" 33-11/16" to 34-11/16" stainless steel glass door 17-3/4" 3-5/8" to 4-5/8" 33-11/16" to 34-11/16" 23-7/16" stainless steel overl...

  • Page 7

    U-line door swing dimensions 5 units have a zero clearance for the door to open 90°. Overlay models will need additional space for any knobs or pulls installed on the overlay panel / frame. Stainless steel models require 2" door clearance to accommodate the handle if installed next to a wall. 6 door...

  • Page 8

    U-line 3000 series maintenance 6 door alignment and adjustment align and adjust the door if it is not level, or is not sealing properly. If the door is not sealed the unit may not cool properly, or excessive frost or condensation may form in the interior. Important important properly aligned, the do...

  • Page 9

    U-line door panel installation guide 7 overlay / frame overlay panel important important due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is designed to provide a finished overlay panel that seemlessly integrates with surrounding cabinetry....

  • Page 10

    U-line door panel installation guide 8 panel installation 1. Fully open door, 2. Starting at corner, pull gasket away from door. 3. Continue to pull gasket free from gasket channel. 4. Upon removal, lay gasket down on a flat surface. Important important if working with the door that houses the displ...

  • Page 11

    U-line door panel installation guide 9 5. The frame should be aligned with the outside edge (opposite the hinge) and high enough to align with the highest point in the door. Important important due to differences in floor construction or surrounding cabinetry, the frame may not sit flush with the to...

  • Page 12

    U-line door panel installation guide 10 overlay grille dimensions 3036 models 1" 1-15/32" 35-7/32" 33-9/32" a dimension a ma y var y fr om a minim um of 3-1/4" to a maxim um 4-1/4" depending on toe kick height. Measur e toe kick height and cut o verla y to same dimension. Recommended ov erla y grill...

  • Page 13

    U-line 3000 series anti-tip bracket installation 11 anti-tip brackets installation warning the anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened, or excess weight is placed on the front of the unit. The anti-tip brackets have multiple mounting options. M...

  • Page 14

    U-line 3000 series anti-tip bracket installation 12 3018/3024 top mount top mount configurations work well with fully secured wood or laminate counter tops. 1. Align the brackets on top of your unit as shown below. Both brackets must be used to ensure a secure mount. 2. Using 4 of the supplied 10 #8...

  • Page 15

    Level & install unit 13 10 10 level & install leveling information it is recommended that the unit is level once installed. 1. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown. 2. If the unit is not ...

  • Page 16: Installation Guide

    ® building on three generations of innovation for nearly five decades and three generations, u-line continues to be the leader in innovation, quality and value in the premium built-in undercounter ice making, refrigeration and wine preservation market. U-line has captivated those with an appreciatio...