  • Page 1

    ® the american built-in undercounter leader since 1962 icemaker series uline.Com install guide wh95 bi2115 ada15im bi98 ss98 ss1095 sp18 bi95 models covered • u-ada15imb-00 • u-bi2115sod-01 • uln-bi95wh-20 • uln-ss1095fd-20 • u-ada15ims-00 • u-bi2115sod-20 • uln-bi98b-00 • uln-ss1095nf-03 • u-ada15i...

  • Page 2

    Safety precautions safety alert definitions.........................................................................................................................................1 general precautions .....................................................................................................

  • Page 3

    Precautions 1 important important • please read all instructions before installing, operating, or servicing the appliance. • proper installation procedures must be followed when completing an installation or relocation of a unit. Consult the installation guide before any installation begins. U-line ...

  • Page 4

    3 inspect & plan 2 u-line inspect & plan product registration you have received a carton containing your ice maker unit with a package inside containing a use and care guide, a product registration card, and a water line kit. Please complete and mail the product registration card or register online ...

  • Page 5

    4 prepare site prepare site 3 your u-line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must not be obstructed and clearance is required for an electrical a...

  • Page 6

    4 u-line prepare site ss-1095nf models ss-1095fc models ss1095fd bcm95 models wh95tp models bi95btp 8" typical counter height 34-1/4" to 35-1/8" cut-out height 25-1/16" filler panel (not provided by u-line) – may be added above or below unit to enclose for a built-in look 14-1/4" 18-1/2" minimum see...

  • Page 7

    Product dimensions 5 17"* 25-1/16" 15-1/8" 8 15/16” *add 1-1/2” for for water line clearance 5 product dimensions ada15im series bi95(b)(wh) bi2115 *add 5/8” for water line clearance 23-3/16" 34-1/8" 15" 3-13/16” *add 5/8” for water line clearance 15" 34-1/8" 3-13/16” 23-1/8” bi2115 stainless *add 1...

  • Page 8

    6 product dimensions ss1095fc ss1095nf 15-15/16” 17” * 26-1/16” 9” *add 1 1/2” for water line clearance *add 1 1/2” for water line clearance 17” * 25-1/8” 15-1/8” 9” *add 1 1/2” for water line clearance 25-1/16” 14” 17” * 9” 15-1/8" 24-1/2" * 18-7/8" 7 9/16”" 1/2" *add 1-1/2” for water line clearanc...

  • Page 9

    Other site requirements 7 door swing dimensions all units have a zero clearance for the door to open 90°. U-line recommends a minimum door clearance of 2" to accommodate the handle if the unit is installed next to a wall or similar type of structure. Power supply units requires a grounded and polari...

  • Page 10

    7 door reversal 8 u-line product features bi95 & bi98 reversing the door all units may be left- or right-hand opening. Note: the grille should not yet be installed. If it has been installed, remove it for door reversing. To reverse the door: 1. Remove top hinge from cabinet (three screws). See figur...

  • Page 11

    U-line door reversal 9 wh95tp, bi95btp, bcm95 & sp18 reversing the door all units may be left- or right-hand opening. To reverse the door: 1. Remove travel pin from cabinet (two screws). See figure 9. Slide assembly through flange and set aside to be used later. 2. Remove top hinge from cabinet (thr...

  • Page 12

    10 u-line product features ss1095 reversing the door depending upon the location of the unit, it may be desirable to change the side on which the door is mounted. To reverse the door mounting, perform the following: 1. Remove grille (one screw) (figure 19). 2. Remove top hinge from cabinet (three sc...

  • Page 13

    U-line door reversal 11 13. Remove all three screws on the opposite side of the hinge and carefully lift off the door latch assembly (figure 28). 14. Place the door latch assembly on opposite side of unit (figure 29). Be sure to tighten all three screws securely. 15. Place door on lower hinge pin. I...

  • Page 14

    8 door panel installation 12 u-line product features door panel preparation bi-95, bi-2115b(wh), wh95btp a custom door panel may be inserted into the doorframe. Custom door panels can be flat or raised, as long as the maximum panel thickness, where inserted into the door reveal (channel), is no more...

  • Page 15

    U-line other requirements 13 9 10 power supply electrical specifications warning shock hazard — electrical grounding required. • never remove the round grounding prong from the plug and never use a two-prong grounding adapter. • never use an extension cord to connect power to the unit. Important imp...

  • Page 16

    14 u-line product features 9 11 plumbing caution plumbing installation must observe all state and local codes. All water and drain connections must be made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm. Water supply c...

  • Page 17

    12 install level & install unit 15 leveling information ada15im & bi2115 it is recommended that the unit is level. 1. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown 2. If the unit is not level, adj...

  • Page 18

    16 u-line product features installation troubleshooting problem q: water is leaking under the unit. Solution a: a water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctl...

  • Page 19: Installation Guide

    ® u-line.Com installation guide ©2010 u-line corporation publication number 30287 03/2013 rev. G the american built-in undercounter leader since 1962 building on three generations of innovation for nearly five decades and three generations, u-line continues to be the leader in innovation, quality an...