To change the settings, please read the following instructions for each control:
Vacuum Time: To increase or decrease the vacuum time, press the button until
VACUUM is illuminated and then use the buttons to adjust the vacuum time
accordingly. The time setting will display on the LED Screen on the control panel.
Note: Filler plates can be used to reduce the vacuum time required. Place the filler plates inside the chamber
as desired. Filler plates occupy space, leaving less air to be removed from the chamber. If you require more
space inside the chamber, remove the filler plates to accommodate your product.
Sealing Time: To increase or decrease the sealing time, press the button until
SEALING is illuminated and then use the buttons to adjust the sealing time to
accommodate your application. It is recommended that you make adjustments in 0.1
second increments to avoid melting the pouch.
Note: For thicker pouches, you should increase the seal time in 0.1 second increments until the pouch seals
completely. In addition, for thinner pouches, you should decrease the seal time in 0.1 second increments to
avoid over-sealing the pouch
.
Cooling Time: To increase or decrease the cooling time, press the button until
COOLING is illuminated and then use the buttons to adjust the cooling time
accordingly.
Note: The VP210 settings will always default to the most recently used settings on the machine.
8
Operating Instructions (Continued)
SET
SET
SET