Vaillant auroSTOR VIH S GB 200/3 BES Installation And Maintenance Instructions Manual

Manual is about: auroSTOR VIH S GB .../3 BES

Summary of auroSTOR VIH S GB 200/3 BES

  • Page 1

    For the competent person installation and maintenance instructions aurostor vih s gb .../3 bes gb, ie installation and maintenance instructions publisher/manufacturer vaillant gmbh berghauser str. 40 d-42859 remscheid tel. +49 21 91 18‑0 fax +49 21 91 18‑2810 info@vaillant.De www.Vaillant.De.

  • Page 2

    Contents 2 installation and maintenance instructions aurostor 0020221298_02 contents 1 safety .................................................................... 3 1.1 action-related warnings ......................................... 3 1.2 risk caused by inadequate qualifications.............. 3 1....

  • Page 3

    Safety 1 0020221298_02 aurostor installation and maintenance instructions 3 1 safety 1.1 action-related warnings classification of action-related warnings the action-related warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal wo...

  • Page 4

    1 safety 4 installation and maintenance instructions aurostor 0020221298_02 tact opening of at least 3 mm, e.G. Fuse or line protection switch). ▶ secure against being switched back on again. ▶ check that there is no voltage. 1.4.3 risk of being burned or scalded by hot components ▶ only carry out w...

  • Page 5

    Notes on the documentation 2 0020221298_02 aurostor installation and maintenance instructions 5 2 notes on the documentation 2.1 observing other applicable documents ▶ you must observe all the operating and installation in- structions included with the system components. 2.2 storing documents ▶ pass...

  • Page 6

    4 installation 6 installation and maintenance instructions aurostor 0020221298_02 4 installation 4.1 observing the requirements for the product's installation site caution. Material damage due to frost if the water in the system freezes, there is a risk of damage to the domestic hot water cylinder. ...

  • Page 7

    Installation 5 0020221298_02 aurostor installation and maintenance instructions 7 4.4 checking the scope of delivery 1 2 3 4 5 6 7 ▶ check that the scope of delivery is complete. Refer- ence point quant- ity description 1 1 enclosed documentation 2 1 tundish with retainer 3 1 2-way motorised valve 4...

  • Page 8

    5 installation 8 installation and maintenance instructions aurostor 0020221298_02 caution. Risk of material damage by drilling through the product. The product may be damaged by drilling work. ▶ do not drill through the product. Caution. Risk of material damage to the cylinder. If the cylinder is fi...

  • Page 9

    Installation 5 0020221298_02 aurostor installation and maintenance instructions 9 2 3 4 5 6 7 1 1 connection for the expansion vessel (22 mm) 2 cold water inlet (22 mm) 3 pressure reducer 4 expansion relief valve 5 outlet for the expansion relief valve (15 mm) 6 connecting a pressure gauge (optional...

  • Page 10

    5 installation 10 installation and maintenance instructions aurostor 0020221298_02 sample calculation the following example corresponds to a temperature and pressure reducing valve g1/2 with a discharge pipe (d2) with four 22 mm elbows and a length of 7 m from the tundish to the drain point. Accordi...

  • Page 11

    Installation 5 0020221298_02 aurostor installation and maintenance instructions 11 conditions: installation with secondary return 230~ 1 2 3 5 4 9 8 7 6 10 11 1 cylinder 2 non-return valve 3 thermostat mixing valve 4 controller 5 hot water hose 6 contact thermostat 7 non-return valve 8 circulation p...

  • Page 12

    5 installation 12 installation and maintenance instructions aurostor 0020221298_02 5.3.2.2 immersion heater 70 60 50 40 1 3 2 4 1 2 1 thermal cut-out and fault clearance but- ton for the immersion heater 2 immersion heater tem- perature control 5.3.3 cable route ▶ use the cable ducts that are includ...

  • Page 13

    Installation 5 0020221298_02 aurostor installation and maintenance instructions 13 5.3.5 connecting the solar circuit to the power supply 70 60 50 40 70 60 50 40 1 3 2 4 1 3 2 4 l n 2 1 3 2 2 4 4 1 8 l 8l 8l sl ▶ connect the thermal cut-out. To do this, consult the in- structions for the controller ...

  • Page 14

    6 start-up 14 installation and maintenance instructions aurostor 0020221298_02 5.3.9 connecting the 2-way motorised valve to the power supply ▶ connect the 2-way motorised valve; to do this, see the instructions for the controller or multi-functional module. 6 start-up 6.1 checking and treating the ...

  • Page 15

    Handing the product over to the operator 7 0020221298_02 aurostor installation and maintenance instructions 15 6.2 setting the immersion heater thermostat 70 60 50 40 1 3 2 4 1 the hot water temperature is controlled via the immersion heater thermostat (1). Conditions: without a multi-functional mod...

  • Page 16

    8 troubleshooting 16 installation and maintenance instructions aurostor 0020221298_02 8 troubleshooting 8.1 detecting and rectifying faults ▶ if problems occur whilst operating the product, check certain points with the aid of the table in the appendix. Detecting and rectifying faults (→ page 17) 8....

  • Page 17

    Appendix 0020221298_02 aurostor installation and maintenance instructions 17 appendix a detecting and rectifying faults fault possible cause remedy no throughput at the valve 1. Water supply valve closed 2. Main filter blocked 3. Pressure reducer not installed correctly 1. Check and open the valve. ...

  • Page 18

    Appendix 18 installation and maintenance instructions aurostor 0020221298_02 vih s gb 200/3 bes vih s gb 250/3 bes vih s gb 300/3 bes pressure of the pressure reducer 0.35 mpa (3.50 bar) 0.35 mpa (3.50 bar) 0.35 mpa (3.50 bar) opening pressure in the expansion relief valve 0.6 mpa (6.0 bar) 0.6 mpa ...

  • Page 19

    Appendix 0020221298_02 aurostor installation and maintenance instructions 19 vih s gb 200/3 bes vih s gb 250/3 bes vih s gb 300/3 bes 3-way motorised valve 230/240 v, 50hz 230/240 v, 50hz 230/240 v, 50hz thermostat 230/240 v, 50hz 230/240 v, 50hz 230/240 v, 50hz level of protection 21 21 21 technica...

  • Page 20: Www.Centralheating.Co.Uk

    Appendix 20 installation and maintenance instructions aurostor 0020221298_02 d commissioning checklist © heating and hotwater industry council (hhic) www.Centralheating.Co.Uk benchmark commissioning and servicing section it is a requirement that the boiler is installed and commissioned to the comple...

  • Page 21

    Appendix 0020221298_02 aurostor installation and maintenance instructions 21 this commissioning checklist is to be completed in full by the competent person who commissioned the storage system as a means of demonstrating compliance with the appropriate building regulations and then handed to the cus...

  • Page 22

    Appendix 22 installation and maintenance instructions aurostor 0020221298_02 it is recommended that your hot water system is serviced regularly and that the appropriate service record is completed. Service provider before completing the appropriate service record below, please ensure you have carrie...

  • Page 23

    Index 0020221298_02 aurostor installation and maintenance instructions 23 index a article number ....................................................................... 5 c ce label................................................................................. 5 checking the pre-charge pressure of...

  • Page 24

    0020221298_02 09.08.2016 supplier vaillant ltd. Nottingham road belper derbyshire de56 1jt telephone 0330 100 3461 info@vaillant.Co.Uk www.Vaillant.Co.Uk © these instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written conse...