Vaillant ecoVIT exclusiv VKK 226/4-H Operating Instructions Manual

Summary of ecoVIT exclusiv VKK 226/4-H

  • Page 1

    Operating instructions ecovit exclusiv vkk 226/4 – vkk 656/4 at, de publisher/manufacturer vaillant gmbh berghauser str. 40 d-42859 remscheid tel. +49 21 91 18 ‑ 0 fax +49 21 91 18 ‑ 2810 info@vaillant.De www.Vaillant.De.

  • Page 2

    Contents 2 operating instructions ecovit exclusiv 0020258609_00 contents 1 safety .................................................................... 3 1.1 action-related warnings ......................................... 3 1.2 intended use .............................................................

  • Page 3

    Safety 1 0020258609_00 ecovit exclusiv operating instructions 3 1 safety 1.1 action-related warnings classification of action-related warnings the action-related warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal words: warning...

  • Page 4

    1 safety 4 operating instructions ecovit exclusiv 0020258609_00 ▶ alert the police and fire brigade as soon as you are outside the building. ▶ use a telephone outside the building to inform the emergency service department of the gas supply company. 1.3.4 risk of death due to a blocked or leaking fl...

  • Page 5

    Notes on the documentation 2 0020258609_00 ecovit exclusiv operating instructions 5 2 notes on the documentation 2.1 observing other applicable documents ▶ you must observe all operating instructions enclosed with the system components. 2.2 storing documents ▶ keep this manual and all other applicab...

  • Page 6

    3 product description 6 operating instructions ecovit exclusiv 0020258609_00 3 control (accessory) 4 main switch 5 + button 6 − button 7 reset button 8 heating flow temperat- ure rotary knob 9 cylinder temperature rotary knob the display shows the current heating flow temperature, the filling pressu...

  • Page 7

    Operation 4 0020258609_00 ecovit exclusiv operating instructions 7 3.4 frost protection function the product is equipped with a frost protection function. If the heating flow temperature falls below 5 °c when the main switch is on, the product starts up and heats the cir- culating water to approx. 3...

  • Page 8

    4 operation 8 operating instructions ecovit exclusiv 0020258609_00 4.2.3 switching off the product 1 2 1 main switch 2 display ▶ use the main switch (1) to switch off the product. ◁ 0 : "off" note in order for the protection modes, such as frost protection, to remain activated, only ac- tivate and d...

  • Page 9

    Operation 4 0020258609_00 ecovit exclusiv operating instructions 9 4.5 setting the cylinder temperature conditions : control connected 1 2 1 display 2 cylinder temperature rotary knob ▶ set the rotary knob for the cylinder temperature (2) as far as it will go clockwise so that the control can work w...

  • Page 10

    5 care and maintenance 10 operating instructions ecovit exclusiv 0020258609_00 4.6.3 switching off cylinder charging mode (without control) ▶ turn the rotary knob for the cylinder temperature to the anti-clockwise end stop. ◁ cylinder charging mode is switched off. ◁ the frost protection function is...

  • Page 11

    Care and maintenance 5 0020258609_00 ecovit exclusiv operating instructions 11 5.3.2 filling the heating installation caution. Risk of material damage due to heating water that is extremely calciferous or cor- rosive or contaminated by chemicals. Unsuitable tap water damages the seals and diaphragms...

  • Page 12

    6 troubleshooting 12 operating instructions ecovit exclusiv 0020258609_00 – immersion depth: ≈ 80 mm 6. Take measurements in the air route on the combustion air test opening (2) . – immersion depth: ≈ 10 mm 7. Switch off the chimney sweep function by pressing the − and + buttons for the dia system a...

  • Page 13

    Recycling and disposal 8 0020258609_00 ecovit exclusiv operating instructions 13 7.2 permanently decommissioning the product ▶ have a competent person permanently decommission the product. 8 recycling and disposal ▶ the competent person who installed your product is re- sponsible for the disposal of...

  • Page 14

    Appendix 14 operating instructions ecovit exclusiv 0020258609_00 appendix a status codes note since the code table is used for various products, some codes may not be visible for the product in question. Statuscode meaning s.00 heating: no heat de- mand heating has no heat demand. The burner is off....

  • Page 15

    Appendix 0020258609_00 ecovit exclusiv operating instructions 15 symptom possible cause measure no hot water, heating stays cold fault during the ignition pro- cess. F.28 "no ignition during start-up" or f.29 "flame goes out during operation" appears in the display. The symbol is shown in the displa...

  • Page 16

    0020258609_00 24.05.2017 supplier vaillant deutschland gmbh & co.Kg berghauser str. 40 d-42859 remscheid telefon 021 91 18 ‑ 0 telefax 021 91 18 ‑ 2810 auftragsannahme vaillant kundendienst 021 91 5767901 info@vaillant.De www.Vaillant.De © these instructions, or parts thereof, are protected by copyr...