Vaillant time SWITCH 130 Instructions For Use And Installation

Manual is about: 24 hour time clock

Summary of time SWITCH 130

  • Page 1

    Time switch 130 24 hour time clock for the user / for the installer instructions for use and installation gb 838311_01gb_052005.Qxd 23.05.2005 8:49 uhr seite 2.

  • Page 2

    Contents 2 gb gb 24 hour time clock operating instructions page 4 - 9 installation instructions page 10 - 12 figures page 3, 14 - 16 ec declaration of conformity page 17 all vaillant boilers have a built in frost thermostat. This time clock is not suitable for use with an external frost thermostat. ...

  • Page 3

    1 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 9 3 12 6 time switch off on 1 2 3 4a 4b 5 3 fig. 1: gb fig. 1 838311_01gb_052005.Qxd 23.05.2005 8:49 uhr seite 4.

  • Page 4: 1 Operating Mode Switch

    Gb 1 operating mode switch the time is controlled as follows: heating constantly off ”off” heating constantly on ”on” automatic heating programme ” ” 2 minute hand * for showing and setting the time 3 reference triangle * indicates the time of day e.G. Fig. 1 ”15.00” 4a slide in the tappets tappet i...

  • Page 5

    Contents 5 1 operating summary page 4 2 selecting the operating mode page 6 3 setting the timer page 7 4 programming heating periods page 8 5 special operating conditions page 9 6 installation instructions page 10 7 commissioning page 11 8 technical data page 12 gb 838311_01gb_052005.Qxd 23.05.2005 ...

  • Page 6

    Gb 2 selecting of the operating mode 6 2.1 selecting the operating mode with the operating mode switch fig. 1 (1), you can change the operating mode of your heating system according to your requirements. In position ”on” , the heating is constantly on. In position ”off”, the heating is constantly of...

  • Page 7: 3.1 Setting The Timer

    Gb 3 setting the timer 7 3.1 setting the timer 3.1.1 reading time of day the time of day can be read on the clock face below the reference triangle. Note: the timer uses a 24 hour clock scale. 3pm is therefore 15:00. 3.1.2 setting the timer turn the minute hand clockwise until the reference triangle...

  • Page 8: 4.1 Setting The Tappets

    Gb 4 programming heating periods 8 4.1 setting the tappets set the tappets (4a) and (4b) as follows: for heating on periods stick the tappets (4a) inwards. For heating off periods stick the tappets (4b) outwards. 4.2 setting the heating programme set the tappets (3) and (4) according to your heating...

  • Page 9: 5.1 Weekend Operation

    Gb 9 5 special operating conditions 5.1 weekend operation if the heating is to be switched - on temporarity, e.G. During the weekend, turn the operating mode switch (1) to the position ”on”. To return to automatic operation, turn the operating mode switch back to position . 5.2 summer-time operation...

  • Page 10: 6 Installation Instructions

    Gb 6 installation instructions all electrical work shall be undertaken by a competent person and shall comply with bs 7671 (iee regulations). · turn off the boiler. · isolate the electrical supply to the boiler 6 installation instructions 10 · release the time clock blanking plate from the control b...

  • Page 11: 7 Commissioning

    Gb 7 commissioning 7 commissioning turn on the electrical supply to the boiler and timer and commission as detailed in the instructions for installation supplied with the boiler. The ce mark demonstrates that this timeclock fulfills the essential requirements of the low voltage directive (73/23/eec)...

  • Page 12

    Gb 8 technical data 12 24 hour time clock 24 v dc 35 ma max approx. 200 g ip 20 ii –25...+70°c appliance type operating voltage current input weight protection class type of enclosure permissible storage temperature 838311_01gb_052005.Qxd 23.05.2005 8:49 uhr seite 13.

  • Page 13

    13 gb 838311_01gb_052005.Qxd 23.05.2005 8:50 uhr seite 14.

  • Page 14

    Gb fig. 2 7 blanking plate 8 installation recess 9 24h time clock 14 838311_01gb_052005.Qxd 23.05.2005 8:50 uhr seite 15.

  • Page 15

    Gb 1 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 9 3 12 6 time switch off on 8 9 7 fig. 2 15 fig. 2: 838311_01gb_052005.Qxd 23.05.2005 8:50 uhr seite 16.

  • Page 16

    Gb fig. 3: 10 fig. 3 10 pins 16 838311_01gb_052005.Qxd 23.05.2005 8:50 uhr seite 17.

  • Page 17

    Gb ec declaration of conformity 17 838311_01gb_052005.Qxd 23.05.2005 8:50 uhr seite 18.

  • Page 18

    83 83 11_01 gb 05 2 005 s ubject t o alt er ation 838311_01gb_052005.Qxd 23.05.2005 8:49 uhr seite 1.