  • Page 1

    For the user v 12-025 w v 12-035 w v 12-050 w v 12-060 w v 12-060 m2w user manual air conditioner - climavair split wall-mounted type en.

  • Page 2

    2 contents split wall-mounted user manual contents 1 your safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.1 symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 proper use of the unit . . . . . . . . . . . . . . . . . . . . . . . 3 2 extreme operating ...

  • Page 3

    3 split wall-mounted user manual en 1 your safety 1.1 symbols used danger! Direct danger for life and health. Danger! Danger of electric shock. Warning! Potentially dangerous situation for the product and the environment note! Useful information and indications 1.2 proper use of the unit this unit h...

  • Page 4

    4 split wall-mounted user manual 3 identification of the unit this manual is valid for the split system series. In order to know the specific model of your unit please refer to the unit nameplates. The nameplates are located on the outdoor and indoor units. 4 declaration of conformity the manufactur...

  • Page 5

    5 split wall-mounted user manual en 5.2 features and benefits function description valve protection a cover used to protect the service valves from the effects of bad weather anti-freeze all heat pump units will tend to freeze up during the colder winter months, the anti-freeze function automaticall...

  • Page 6

    6 split wall-mounted user manual 6 getting started 6.1 fitting the remote controller batteries insert the batteries (2 no. Size aa), as described below (see figure 6.1).. Fig. 6.1 fitting the remote controller batteries. Legend 1 battery lid 2 batteries a pressure area for opening the lid b battery ...

  • Page 7

    7 split wall-mounted user manual en 7.2 identification of functions 7.2.1 remote controller buttons fig. 7.1 overview of the buttons. Legend 1 on/off button 2 + - buttons (increase/decrease) 3 mode button (operation mode) 4 swing button 5 fan button (fan speed) 6 sleep button (night time function) 7...

  • Page 8

    8 split wall-mounted user manual 7.3 advice on how to use the remote controller follow the recommendations below as to how to use the remote controller: - when in use, direct the head of the signal transmitter directly to the indoor unit receiver. - keep the distance between the transmitter and the ...

  • Page 9

    9 split wall-mounted user manual en operating instructions 7 7.5.4 heating mode (heat) in heating mode, the air conditioning only allows heating. In order to activate: with the unit connected (see section 7.4): • press the mode button. • select the heating operation mode (heat). • press the + - butt...

  • Page 10

    10 split wall-mounted user manual 7.8 turbo press turbo button during cool or heat mode operation. The air rate can be set to high and continue to operate for 15 minutes. Press turbo button again twice to release the turbo mode operation. 7.9 special function selection 7.9.1 sleep function the cool,...

  • Page 11

    11 split wall-mounted user manual en 7.9.2 timer function (connection using timer) the unit can be automatically connected/disconnected using the timer. Note! Before starting, make sure that the clock is adjusted correctly. In order to set the unit to disconnect automatically: with the unit connecte...

  • Page 12

    12 split wall-mounted user manual 8 advice for saving energy 8.1 suitable room temperature set the room temperature to an appropriate value to guarantee physical wellbeing, comfort and, in any case, to comply with the legal standard. Each degree above this value significantly increases the energy co...

  • Page 13

    13 split wall-mounted user manual en 9 troubleshooting the table below describes a selection of problems with their possible causes and solutions, see table 9.1. If these solutions do not solve the problem contact your usual installer or call your nearest vaillant office. Symptoms possible causes po...

  • Page 14

    14 split wall-mounted user manual 10 maintenance danger! Danger of electric shock. Disconnect the unit and isolate the mains supply before proceeding to carry out maintenance on the unit. This will prevent injuries. Danger! Danger of electric shock. Do not clean the unit with water. Warning! Danger ...

  • Page 15

    15 split wall-mounted user manual en 11 storage over a prolonged period if you do not intend to use the unit over a period of time: • put the fan into operation for half a day at a temperature of 30ºc in order to dry the inside of the unit. • stop the unit and disconnect the power switch. • clean th...

  • Page 16

    V12 -w -m2w -u_en 0 7/ 2 009 v aillan t re serv es the righ t to mak e modif ic ations without prior w arning. Vaillant ltd vaillant house medway city estate trident close rochester kent me2 4ez telephone 0164 292300 fax 0164 290166 www.Vaillant.Co.Uk info@vaillant.Co.Uk.