Vaillant VRT 360 Operating and Operating And Installation Manual

Manual is about: Programmable room thermostat with separat HW time control

Summary of VRT 360 Operating and

  • Page 1

    For the owner and the heating engineer operating and installation manual vrt 360 programmable room thermostat with separat hw time control gb.

  • Page 2: Contents

    2 contents vrt 360 operating and installation manual contents notes on the documentation . . . . . 4 symbols used........................................... 4 storage of the documents.................... 4 safety . . . . . . . . . . . . . . . . . . . . . . . . 5 operating manual. . . . . . . . . . ....

  • Page 3

    3 vrt 360 operating and installation manual contents installation manual . . . . . . . . . . . . . 25 7 information on installation and operation . . . . . . . . . . . . . . 25 7.1 ce label............................................. 25 7.2 intended use.................................... 25 8 safe...

  • Page 4: Notes On The Documentation

    4 vrt 360 operating and installation manual notes on the documentation notes on the documentation the following information is intended to help you throughout the entire docu- mentation. Other documents apply in combination with this installation and operation man- ual. We accept no liability for an...

  • Page 5: Safety

    5 vrt 360 operating and installation manual safety safety the room thermostat must be installed by an authorised heating engineering company, which is responsible for com- pliance with the applicable standards and regulations. We accept no liability for damage resulting from failure to observe these...

  • Page 6: Operating Manual

    6 vrt 360 operating manual 1 room thermostat overview operating manual 1 room thermostat over- view 1 2 fig. 1.1 room thermostat overview key 1 display 2 dial (turn and click) i info button f special functions button p programming button/installer level.

  • Page 7: 2 Display

    7 vrt 360 operating manual display overview 2 2 display overview 4 1 2 3 5 6 7 8 9 10 11 12 fig. 2.1 display overview key 1 installer level and service/diagnosis level (see 11.1) 2 info level (see 4.7) 3 hot water symbol 4 time / temperature display 5 days of the week 6 actual temperature 7 operatin...

  • Page 8: Description Of The Room

    8 vrt 360 operating manual 3 description of the room thermostat, 4 operation 3 description of the room thermostat the vrt 360 is a programmable room thermostat with a weekly programme for heating, hot water and a circulation pump for connecting to vaillant boilers with an ebus. The vrt 360 enables y...

  • Page 9

    9 vrt 360 operating manual operation 4 4.1 setting the operating modes table 4.1 contains an overview of the operating modes you can select. The selected operating mode affects the timer programmes both for heating and for hot water and the circulation pump. • when the room thermostat is in nor- mal...

  • Page 10

    10 vrt 360 operating manual 4 operation symbol meaning heating hot water automatic: according to the timer programme set in the room ther- mostat, the heating circuit switches between heating and set-back mode. The heating circuit symbol is displayed if a heating requirement is detected. The operati...

  • Page 11

    11 vrt 360 operating manual operation 4 symbol meaning heating hot water off: the heating circuit is off, provided that the frost protection function (if the room tem- perature is below 5 °c) is not activated. If the frost protection function is activated, the heating circuit symbol is displayed. Th...

  • Page 12

    12 vrt 360 operating manual 4 operation 4.2 setting the current day and time to set the current day and time with the display in normal mode, you must per- form the following steps: • press the dial until a day of the week starts flashing. • turn the dial until you see the current day of the week. M...

  • Page 13

    13 vrt 360 operating manual operation 4 4.3 setting timer programmes the room thermostat is equipped with a basic program (see table 4.2). Time window day / block of days start time end time h1 m0 - fr 6:00 22:00 h2 — — — h3 — — — h1 sa 7:30 23:30 h2 — — — h3 — — — h1 su 7:30 22:00 h2 — — — h3 — — —...

  • Page 14

    14 vrt 360 operating manual 4 operation water timer programme. If you want to change the timer programme for heating or the circulation pump, after pressing the programming button p, select the corresponding symbol (heating circuit or circulation pump) and continue as shown in the example. Display r...

  • Page 15

    15 vrt 360 operating manual operation 4 display required steps press the dial. The cursor marks the days of week dis- play, which also flashes. Select a block of days or a single day of the week by turning the dial. Settings: mo - su mo - fr sa - su mo = monday tu = tuesday we = wednesday th = thurs...

  • Page 16

    16 vrt 360 operating manual 4 operation if necessary, you can switch the room thermostat from the week programme to a daily programme. • with the display in normal mode, press the f button for 10 seconds. When you programme time windows, days of the week will no longer be dis- played. 4.4 setting th...

  • Page 17

    17 vrt 360 operating manual operation 4 the display switches back to normal mode after five seconds. Setting the room temperature for time windows (only possible if the temperature level function is activated on the installer level – see 11.1). In this case, you can set different room temperatures f...

  • Page 18

    18 vrt 360 operating manual 4 operation the display switches back to normal mode after five seconds. Setting the set-back temperature “eco” • keep pressing the dial until eco appears in the display. The set-back temperature is displayed and starts flashing. • turn the dial until the required set- ba...

  • Page 19

    19 vrt 360 operating manual operation 4 4.6 activating special functions press the f button to access the special functions. You can activate the following functions: display required steps quick veto the quick veto function allows you to adjust the room tempera- ture for a short time (until the nex...

  • Page 20

    20 vrt 360 operating manual 4 operation display required steps energy-saving function the energy-saving function lets you lower the heating for an adjustable period regardless of the set heating programme. Press the special function but- ton twice and the energy-saving symbol appears on the display....

  • Page 21

    21 vrt 360 operating manual operation 4 display required steps one-time recharging / cylinder boost this function allows you to fill the cylinder, regardless of the set timer programme. Press the special function button four times. The once-only cylinder filling symbol appears in the display and the...

  • Page 22

    22 vrt 360 operating manual 4 operation display required steps ¬ holiday function holiday function if you want to deactivate the function early, just press the f button. If the anti-legionnaire‘s disease function is activated, it is performed on the last day of the holiday. Table 4.4 special functio...

  • Page 23: 5 Vaillant

    23 vrt 360 operating manual operation 4, vaillant warranty 5 - the current set-back temperature (e.G. Eco 15.0 °c) - the set hot water temperature (e.G. Dhw 60 °c) - the day/month/year (if the calendar is activated) - set timer programmes for heating (every single time window per day) - set timer pr...

  • Page 24: Recycling and Disposal

    24 vrt 360 operating manual 6 recycling and disposal 6 recycling and disposal neither your room thermostat or any of its accessories belong in the household waste. Make sure the old room thermo- stat and any accessories are disposed of properly..

  • Page 25: Installation Manual

    25 vrt 360 installation manual information on installation and operation 7 installation manual 7 information on installa- tion and operation the assembly, electrical connection, room thermostat settings and commis- sioning may only be carried out by an approved company specialising in heat- ing engi...

  • Page 26: Safety Instructions and

    26 vrt 360 installation manual 7 information on installation and operation, 8 safety instructions and regulations location, in connection with a vaillant boiler with an ebus interface. Any other use or extended use is consid- ered to be improper. The manufacturer or supplier is not liable for any re...

  • Page 27

    27 vrt 360 installation manual safety instructions and regulations 8 8.1 safety instructions danger! Risk of fatal electric shock from touching live connections. Before working on the room ther- mostat, switch off the power supply and prevent it from being switched on again. Only remove the room the...

  • Page 28: 9 Installation

    28 vrt 360 installation manual 8 safety instructions and regulations, 9 installation the room thermostat may only be installed in dry rooms. 9 installation 9.1 place of installation install the room thermostat so that it can properly measure the room temper- ature (avoid heat traps, cold walls etc.)...

  • Page 29

    29 vrt 360 installation manual installation 9 4 2 3 1 5 3 4 fig. 9.1 mounting the room thermostat • pull the room thermostat (1) out of the mounting box (5). • drill two holes (3) of 6 mm diameter (as shown in fig. 9.1) and put in the supplied wall plugs. • guide the connection cable through the duc...

  • Page 30: 10 Electrical

    30 vrt 360 installation manual 10 electrical installation 10 electrical installation the electrical connection may only be carried out by a suitably qualified engi- neer. Danger! Risk of fatal electric shock from touching live connections. Before working on the room thermostat, turn off the power su...

  • Page 31: 11 Start-Up

    31 vrt 360 installation manual electrical installation 10, start-up 11 boiler 9 8 7 5 4 3 + - n l bus + - vrt 360 bus bus 9 8 7 5 4 3 n l fig. 10.1 electrical connection 11 start-up some system parameters have to be set in order for them to best suit the actual conditions. These system parameters ar...

  • Page 32

    32 vrt 360 installation manual 11 start-up 11.1 installer level press the p button to access the installer level. • press the p button for 10 seconds. The spanner symbol and the first parameter appear in the display. • press the dial. You can select all the system parameters in turn. • turn the dial...

  • Page 33

    33 vrt 360 installation manual start-up 11 display set by turning the dial anti-legionnaire’s disease system 1 = activate the anti-legion- naire‘s disease programme. Every wednesday, one hour before the first time win- dow, a connected hot water cylinder is heated to 70 °c, and the circulation pump ...

  • Page 34

    34 vrt 360 installation manual 11 start-up display set by turning the dial control characteristics/ route adjustment for optimum adaptation to the room size or radiator configuration. Default setting: 0 adjustment range: -5 ... +5 (positive values: room thermostat switches more slowly; negative valu...

  • Page 35

    35 vrt 360 installation manual start-up 11 display set by turning the dial temperature level activate the setting for different temperatures for each time window. 0 = temperature level off 1 = temperature level on default setting: 0 temperature level time window h1 (only when temperature levels are ...

  • Page 36

    36 vrt 360 installation manual 11 start-up 11.2 service/diagnostic level access the service/diagnostic level by pressing the p button and the dial. • press the p button and the dial simul- taneously for 3 seconds. First, a heating request for 50 °c is trig- gered to test communication with the boile...

  • Page 37

    37 vrt 360 installation manual start-up 11 dial test test procedure turn circulation pump the circulation pump is activated. All other elements are switched off. Press display test all display elements are displayed. Press software ver- sion the software version is displayed. Table 11.2 service/diag...

  • Page 38: 12 Technical

    38 vrt 360 installation manual 12 technical data, 13 vaillant customer service 12 technical data description unit operating voltage u max v 24 maximum ambient tempera- ture °c 50 current consumption ma ≤ 17 minimum cross-section of wires mm 2 0.75 level of protection ip 20 protection class iii dimen...

  • Page 39

    39 vrt 360 operating and installation manual declaration of conformity.

  • Page 40

    83 8 5 68_00 gb 04 2 005.