Vaillant VU GB 1006/5-5 Operating Instructions Manual

Manual is about: Gas-fired wall-hung high-efficiency boiler

Summary of VU GB 1006/5-5

  • Page 1

    Operating instructions for the operator gb, ie operating instructions ecotec gas-fired wall-hung high-efficiency boiler.

  • Page 2

    Table of contents 2 operating instructions ecotec plus 0020134822_01 table of contents 1 notes on the documentation ..................................... 3 1.1 storing documents .......................................................... 3 1.2 applicability of the instructions ..........................

  • Page 3

    Notes on the documentation operating instructions ecotec plus 0020134822_01 3 1 1 notes on the documentation the following instructions are intended to guide you throughout the entire documentation. Other documents apply in addition to these operating instructions. We accept no liability for any dam...

  • Page 4

    4 operating instructions ecotec plus 0020134822_01 a safety a 2 2 safety 2.1 safety and warning information > when operating your boiler, observe the general safety information and the warning notes that appear before each action. 2.1.1 classification of warnings the warning notes are classified in ...

  • Page 5

    Operating instructions ecotec plus 0020134822_01 5 a safety a 2 2.3 general safety information > observe the following safety instructions at all times. Installation and settings the boiler must only be installed by a suitably qualified competent person. The existing regulations, rules and guideline...

  • Page 6

    6 operating instructions ecotec plus 0020134822_01 a safety a 2 caution. Frost protection and monitoring devices are only active while the boiler is connected up to the power supply. The boiler must be connected to the power supply. The boiler must be switched on. You can see from symbols and/or tex...

  • Page 7

    Description of devices and functions operating instructions ecotec plus 0020134822_01 7 3 3 description of devices and functions 3.1 design 1 3 2 3.1 front view of the ecotec plus key 1 controls 2 plate with serial number on the rear 2 front flap the controls for your boiler are arranged behind the ...

  • Page 8

    Operation 8 operating instructions ecotec plus 0020134822_01 4 4 operation 4.1 overview of the controls 1 2 3 4 5 4.1 ecotec plus controls 1 on/off button for switching the boiler on or off 2 controller (accessory) the digital information and analysis system consists of: 3 fault clearance key to cle...

  • Page 9

    Operation operating instructions ecotec plus 0020134822_01 9 4 displayed symbols flame: permanently on: correct burner operation; burner on display of the current burner modulation rate (bar graph display) display of the current filling pressure of the heating installation (bar graph display). The f...

  • Page 10

    Operation 10 operating instructions ecotec plus 0020134822_01 4 with both selector buttons + at the same time: – you can navigate to the menu (¬ section 6) with the minus button or the plus button : – you can go back and forth between the individual points of the entry list in the menu – you can inc...

  • Page 11

    Operation operating instructions ecotec plus 0020134822_01 11 4 4.6 preparing for start-up 4.6.1 opening the isolator devices i the isolator devices are included in the scope of delivery of your boiler. The isolator devices are fitted by your competent person on site. > he must explain to you the po...

  • Page 12

    Operation 12 operating instructions ecotec plus 0020134822_01 4 4.6.3 checking the filling pressure of the heating installation b caution. Low filling pressure may cause damage to the unit. Operating the heating installation with low filling pressure can cause damage to the boiler and the heating in...

  • Page 13

    Operation operating instructions ecotec plus 0020134822_01 13 4 the heating installation is filled via a filling cock provided by the installer (if a system separation device is used between the unit heating circuit and the building heating circuit). > ask your competent person where the filling coc...

  • Page 14

    Operation 14 operating instructions ecotec plus 0020134822_01 4 4.8 hot water generation a danger! Risk of being scalded by hot water! There is a danger of scalding at the hot water draw-off points when the tempera- tures are in excess of 60 °c. Young children and elderly persons are particularly at...

  • Page 15

    Operation operating instructions ecotec plus 0020134822_01 15 4 dhw temperature cylinder charging off cancel ok 4.13 switching off cylinder charging > press the left-hand selector button (" "). The domestic hot water temperature that is set is shown flashing on the display. > use the minus button to...

  • Page 16

    Operation 16 operating instructions ecotec plus 0020134822_01 4 4.11 protecting the heating installation against frost b caution. Risk of damage caused by frost. Frost protection and monitoring devices are only active while the boiler is connected up to the power supply and the on/off switch is on. ...

  • Page 17

    Troubleshooting operating instructions ecotec plus 0020134822_01 17 5 5 troubleshooting a danger! Risk of injury and material damage due to incorrect maintenance and repairs! If maintenance is not carried out, or it is carried out incorrectly, this may adversely affect the operational reliability of...

  • Page 18

    Troubleshooting 18 operating instructions ecotec plus 0020134822_01 5 5.2 reading fault codes if a fault develops in the boiler, the display shows a fault code starting with "f...". A plain text display explains the displayed fault code. Example for f.10 "flow ntc short cir- cuit". Fault codes have ...

  • Page 19

    Troubleshooting operating instructions ecotec plus 0020134822_01 19 5 5.4 rectifying low water pressure b caution. Tap water that is extremely calciferous or corrosive or contaminated by chemi- cals can cause material damage. Unsuitable tap water damages the seals and diaphragms, blocks components i...

  • Page 20

    Auxiliary functions 20 operating instructions ecotec plus 0020134822_01 6 5.6 service message 58 5.4 service message if the open-ended spanner is displayed, the boiler requires a service. > consult your competent person about doing this. The boiler is not in fault mode but continues to operate. > in...

  • Page 21

    Auxiliary functions operating instructions ecotec plus 0020134822_01 21 6 6.1.2 overview of the menu structure menu installer level reset burner off time information back select cancel ok display contrast 20 serial number 21 10 43 0001000033no 0010011621 back menu water pressure live monitor informa...

  • Page 22

    Auxiliary functions 22 operating instructions ecotec plus 0020134822_01 6 6.2 displaying the live monitor (current status of the boiler) s.04 heating mode burner on back 6.3 live monitor (current status of the boiler, example) menu ¬ live monitor this function allows you to display the current statu...

  • Page 23

    Service operating instructions ecotec plus 0020134822_01 23 7 > use the minus button or plus button to scroll until your language appears. 6.5 displaying contact data for the competent person contact data 0219118 back 6.6 displaying contact data menu ¬ information ¬ contact data if your competent pe...

  • Page 24

    24 operating instructions ecotec plus 0020134822_01 8 decommissioning 8 decommissioning > contact a competent person to disconnect the boiler permanently. 8.1 disposing of the boiler do not dispose of your vaillant ecotec plus boiler or any of its accessories in the household waste. > make sure the ...

  • Page 25

    Glossary operating instructions ecotec plus 0020134822_01 25 10 10 glossary air/flue gas duct the air/flue gas duct consists of all components that route combustion air to the boiler or flue gas away from the boiler. Burner the burner on a gas-fired condensing boiler is the compo- nent on whose surf...

  • Page 26

    Index 26 operating instructions ecotec plus 0020134822_01 index a air/flue gas duct ......................................................................... 25 air/flue gas pipe .......................................................................... 20 anti-legionella function .....................

  • Page 27

    Brief operating instructions for detailed information, please read the corresponding section in these installation instructions. 1. Switching off heating mode (summer mode) (¬ section 4.10.2) 50 50 target flow temp. Back heating off target flow temp. Cancel ok > right-hand selector but- ton " " > –-...

  • Page 28

    00 2 0134 8 2 2_01 gbie 06 2 012 – s ubject t o change manufacturer supplier.