    Gb vwz meh 60 installation instructions and instructions for use for the competent person and the operator installation instructions and instructions for use.

  • Page 2

    0020152779_05 - 10/14 - vaillant 2 1 safety ....................................................................... 3 1.1 intended use .............................................................3 1.2 symbols used ............................................................3 1.3 qualifi cations ......

  • Page 3

    0020152779_05 - 10/14 - vaillant 3 en safety 1 safety this manual is also available on our web site. Www.Vaillant.Com 1.1 intended use this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowle...

  • Page 4

    0020152779_05 - 10/14 - vaillant 4 safety 1.4.5 risk of structural damages by escaping water incorrect installation can cause leakages. ► make sure there are no stresses in the hydraulic lines. ► correctly position the seals. 1.5 intended use the product is a state-of-the-art product which has been ...

  • Page 5

    0020152779_05 - 10/14 - vaillant 5 en safety gb: the following codes of practice apply: bs4814, bs6798, bs5440 part 1 and 2, bs5546 part 1, bs5449, bs6891, bs6700, bs7074 part 1 and 2, bs7593, bs7671. Ie: i.S.813, bs5546, bs 5449, bs 7074, bs 7593. Note: for further information, see the current issu...

  • Page 6

    0020152779_05 - 10/14 - vaillant 6 notes on the documentation 2 notes on the documentation 2.1 observe other applicable documents ► observe absolutely all operating and installation instructions enclosed with the product, for the various parts and components of the system. 2.2 storing documents ► pa...

  • Page 7

    0020152779_05 - 10/14 - vaillant 7 en mounting and installation 4 mounting and installation i notes all the drawings dimensions are shown in mm. 4.1 preparing the mounting and installation 4.1.1 delivery and installation on site 4.1.1.1 unpack ► remove the product from its box. ► remove the protecti...

  • Page 8

    0020152779_05 - 10/14 - vaillant 8 mounting and installation 4.1.3 considering the product location 4.1.3.1 surrounding conditions ► ensure that the room in which the appliance is installed is not heated to the maximum recommended room temperature. Recommended room temperature: 25°c. ► do not instal...

  • Page 9

    0020152779_05 - 10/14 - vaillant 9 en mounting and installation b caution! Risk of damage caused by heat transfer when soldering. Heat that is transferred during sol- dering can cause damage (expanded) polypropylene around electrical modul and to the seals in the service valves. ► protect (expanded)...

  • Page 10

    0020152779_05 - 10/14 - vaillant 10 mounting and installation 3-phase supply cable 400 v (5 x 1,5 mm²) heating element relay cable 230 v (3 x 0,75 mm²) 3 2 1 1 electrical casing 2 230 v electrical connection label 3 400 v electrical connection label b caution! Risk of damage from too great voltage. ...

  • Page 11

    0020152779_05 - 10/14 - vaillant 11 en mounting and installation 02 01 l1 l2 n1 l3 1 1 protection mini. 20a 4.4.1.4 400 v connection b caution! ► comply with the instructions on the label affixed inside the electri- cal casing. B caution! ► for 400v connection, you must remove the shunts. 02 01 l1 l...

  • Page 12

    0020152779_05 - 10/14 - vaillant 12 start up b caution! Risk of material damage ► comply with electrical cable routing ► avoid any contact with hot parts (heating coil). ► keep a distance of 10mm between connecting cables and metallic elements that are a heat source. ► to guarantee the minimum tensi...

  • Page 13

    0020152779_05 - 10/14 - vaillant 13 en repair work 5.2 installing the casing 1 1 front casing ► put the front casing back on 5.3 handing over the product to the user after completing the installation: ► answer any questions the user may have. ► draw special attention to the safety instructions which...

  • Page 14

    0020152779_05 - 10/14 - vaillant 14 decommissioning 1 1 reset button ► press the reset button (1). 6.4 checking tightness ► check the water-tightness of the system. 6.5 checking the electrical installation ► check the electrical installation observing all relevant regulations. 6.5.2.1 checking the c...

  • Page 16

    Vaillant gmbh berghauser str.40 d-42859 remscheid telefon 021 91 18-0 telefax 021 91 18-28 10 info@vaillant.De www.Vaillant.De manufacturer supplier 0020152779_05 23.10.2014 vaillant ltd nottingham road belper derbyshire de56 1jt telephone 0330 100 3461 vaillant service solutions 0330 100 3461 spare...