Valcom V-9927A User Manual

Other manuals for V-9927A: Datasheet

Summary of V-9927A

  • Page 1

    Vsp-9927a v-9927a digital multi-tone generator specifications power requirements: -24vdc “b” battery at 100ma operating environment: temperature: 0 to +50° c humidity: 0 to 85% (non-condensing) nominal input/output specifications: input impedance: 600 ohms output impedance: less than 4 ohms min. Out...

  • Page 2

    Code call operation when the v-9927a is connected to the v-9923a code call unit, the v-9927a will respond to the contact closure inputs and issue single chimes in response (see figure 2). At the beginning of a code call sequence, the input source will be faded down about 6db. It will remain at this ...

  • Page 3

    P2 p3 out in burst cont p4 p1 unmute mute p5 tone lvl power on jp1 1 2 3 4 5 6 7 8 com signal in com signal out gnd -24v tones connect com to desired tone relay contact signal in (optional) power supply -24vdc (-) (+) signal out option blocks (jumpers shown in factory default setting)) t2 t1 adjust ...

  • Page 4

    Technical assistance when trouble is reported, verify the unit in question is turned on (the green on led should be observed) and all connections are secure. Assistance in troubleshooting is available from the factory. When calling, you should have a vom available and be calling from the job site. C...