Valcourt FP12 Mundo Installation And Operation Manual

Summary of FP12 Mundo

  • Page 1

    45707a printed in canada 19 ‐ 11 ‐ 2014 read and keep this manual for reference fp12 mundo installation and operation manual us environmental protection agency phase ii certified wood fireplace listed to standards ulc ‐ s610 and ul 127 by an accredited laboratory www.Valcourtinc.Com manufactured by:...

  • Page 2

    2 fp12 mundo ‐ installation and operation manual thank you for choosing this valcourt wood fireplace as one of north america’s largest and most respected wood stove and fireplace manufacturers, stove builder international takes pride in the quality and performance of all its products. We want to hel...

  • Page 3: Table

    Fp12 mundo ‐ installation and operation manual 3 table of content part a - operation and maintenance ........................................ 6 1 safety information .............................................................................. 6 1.1 summary of operation and maintenance cautions and ...

  • Page 4

    4 fp12 mundo ‐ installation and operation manual 5 maintaining your wood heating system ........................................ 24 5.1 fireplace maintenance ...................................................................................................................... 24 5.1.1 plated finish ...

  • Page 5

    Fp12 mundo ‐ installation and operation manual 5 8.7 angled wall radiation shield ............................................................................................................ 65 8.8 chimney support installation ............................................................................

  • Page 6: Part

    6 fp12 mundo ‐ installation and operation manual part a ‐ operation and maintenance please see part b for installation instructions. 1 safety information 1.1 summary of operation and maintenance cautions and warnings • hot while in operation, keep children, clothing and furniture away. Contact may c...

  • Page 7: Please

    Fp12 mundo ‐ installation and operation manual 7 • this appliance should be maintained and operated at all times in accordance with these instructions. • do not elevate the fire by means of grates, and irons or other means. • this fireplace must always be used with the original andirons (see appendi...

  • Page 8: General

    8 fp12 mundo ‐ installation and operation manual 2 general information 2.1 fp12 mundo specifications fuel type cordwood test standards (safety) ulc ‐ s610 and ul 127 test standard (emissions) epa method 28 (40 cfr part 60) heating capacity range* 500 to 2100 sq. Ft. (46.5 to 195 m 2 ) maximum heat o...

  • Page 9

    Fp12 mundo ‐ installation and operation manual 9.

  • Page 10

    10 fp12 mundo ‐ installation and operation manual.

  • Page 11

    Fp12 mundo ‐ installation and operation manual 11 2.2 zone heating and how to make it work for you your new fp12 mundo wood fireplace is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature. This ...

  • Page 12

    12 fp12 mundo ‐ installation and operation manual 2.4 the sbi commitment to you and the environment the sbi team is committed to protecting the environment, so we do everything we can to use only materials in our products that will have no lasting negative impact on the environment. 2.4.1 what is yo...

  • Page 13: Fuel

    Fp12 mundo ‐ installation and operation manual 13 3 fuel 3.1 materials that should not be burned • garbage of any kind, • coal or charcoal, • treated, painted or coated wood, • plywood or particle board, • fine paper, colored paper or cardboard, • salt water driftwood, • manufactured logs containing...

  • Page 14

    14 fp12 mundo ‐ installation and operation manual 3.2.3 log length logs should be cut at least 1” (25 mm) shorter than the firebox so they fit in easily. Pieces that are even slightly too long make loading the fireplace very difficult. The most common standard length of firewood is 16” (400 mm). The...

  • Page 15

    Fp12 mundo ‐ installation and operation manual 15 3.2.5 how to dry firewood firewood that is not dry enough to burn is the cause of most complaints about wood fireplaces. Continually burning green or unseasoned wood produces more creosote and involves lack of heat and dirty glass door. See section 5...

  • Page 16: Operating

    16 fp12 mundo ‐ installation and operation manual you could buy a wood moisture meter to test your firewood. 3.3 manufactured logs do not burn manufactured logs made of wax impregnated sawdust or logs with any chemical additives. Manufactured logs made of 100% compressed sawdust can be burned, but u...

  • Page 17

    Fp12 mundo ‐ installation and operation manual 17 4.1 the use of a fire screen this fireplace has been tested for use with an open door in conjunction with a fire screen (ac01364, sold separately). Make sure the fire screen is properly secured on the fireplace to avoid any risk of sparks damaging yo...

  • Page 18

    18 fp12 mundo ‐ installation and operation manual 4.3.1 conventional fire starting the conventional way to build a wood fire is to bunch up 5 to 10 sheets of plain newspaper and place them in the firebox. Next, place 10 or so pieces of fine kindling on the newspaper. This kindling should be very thi...

  • Page 19

    Fp12 mundo ‐ installation and operation manual 19 4.3.3 two parallel logs place two spit logs in the firebox. Place a few sheets of twisted newspaper between the logs. Now place some fine kindling across the two logs and some larger kindling across those, log cabin style. Light the newspaper. 4.3.4 ...

  • Page 20

    20 fp12 mundo ‐ installation and operation manual 4.4.2 ash removal ash should be removed from the firebox every two or three days of full time heating. Do not let the ash build up in the firebox because it will interfere with proper fire management. The best time to remove ash is after an overnight...

  • Page 21

    Fp12 mundo ‐ installation and operation manual 21 4.4.4 firing each new load hot place the new load of wood on and behind the charcoal, and not too close to the glass. Close the door and open the air control fully. Leave the air control fully open until the firebox is full of flames, the wood has ch...

  • Page 22

    22 fp12 mundo ‐ installation and operation manual 4.4.6 building different fires for different needs using the air control is not the only way to match the fireplace’s heat output to the heat demand. Your house will need far less heat in october than in january to be kept at a comfortable temperatur...

  • Page 23

    Fp12 mundo ‐ installation and operation manual 23 the table below provides a very general indication of the maximum burn cycle times you are likely to experience, based on firebox volume. Firebox volume maximum burn time cubic feet 3 to 5 hours 1.5 c.F. To 2.0 c.F 5 to 6 hours 2.0 c.F. To 2.5 c.F. 6...

  • Page 24: Maintaining

    24 fp12 mundo ‐ installation and operation manual 5 maintaining your wood heating system 5.1 fireplace maintenance your new fireplace will give many years of reliable service if you use and maintain it correctly. Some of the internal components of the firebox, such as firebricks, baffles and air tub...

  • Page 25

    Fp12 mundo ‐ installation and operation manual 25 5.1.3 door adjustment in order for your fireplace to burn at its best efficiency, the door must provide a perfect seal with the firebox. Therefore, the gasket should be inspected periodically to check for a good seal. The gasket seal may be improved ...

  • Page 26

    26 fp12 mundo ‐ installation and operation manual 5.1.4 door alignment to align, open the fireplace’s door and loosen the pressures screws located on the lower and upper hinges of the door using a 5/64” (2mm) allen key to free the adjustable hinge rods..

  • Page 27

    Fp12 mundo ‐ installation and operation manual 27 using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions..

  • Page 28

    28 fp12 mundo ‐ installation and operation manual 5.1.5 replacing the door gasket it is important to maintain the gasket in good condition. After a year or more of use, the door gasket will compress and become hard, which may allow air to leak past it. You can test the condition of the door gasket b...

  • Page 29

    Fp12 mundo ‐ installation and operation manual 29 5.1.6 replacing the glass or the glass gasket the glass used in the fp12 is 5 mm thick of dimension: 31 1/8" (791 mm) x 17 1/4" (438 mm)and tested to reach temperatures up to 1400º f. If the glass breaks, it must be replaced with one having the same ...

  • Page 30

    30 fp12 mundo ‐ installation and operation manual the gasket must be centred on the edge of the glass. To do this easily, peel back a section of the paper covering the adhesive and place the gasket on a table with the adhesive side up. Stick the end of the gasket to the middle of top edge of the gla...

  • Page 31

    Fp12 mundo ‐ installation and operation manual 31 reinstall the glass, being careful to centre the glass carefully in the door. Do not over ‐ tighten the screws. Note that the two main causes of broken door glass are uneven placement in the door and over ‐ tightening of retaining screws. Do not abus...

  • Page 32

    32 fp12 mundo ‐ installation and operation manual 5.2.3 cleaning the chimney chimney cleaning can be a difficult and dangerous job. If you don’t have experience cleaning chimneys, you might want to hire a professional chimney sweep to clean and inspect the system for the first time. After having see...

  • Page 33

    Fp12 mundo ‐ installation and operation manual 33 5.2.5 chimney fire regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow these steps: 1. Close the fireplace door and the air intake controls; 2. Alert your family of the possible danger; 3. If you r...

  • Page 34: Part

    34 fp12 mundo ‐ installation and operation manual part b – installation install the fireplace only as described in these instructions and using only components from the chimney manufacturers listed in table 2. Parts required fp12 mundo fireplace insulated chimney made by the manufacturers listed in ...

  • Page 35

    Fp12 mundo ‐ installation and operation manual 35 • this fireplace has not been tested to be installed inside a masonry chimney. 6.2 regulations covering fireplace installation when installed and operated as described in these instructions, the fp12 mundo wood fireplace is suitable for use in reside...

  • Page 36

    36 fp12 mundo ‐ installation and operation manual 6.3 fireplace installation before installing your fireplace, you must install the two spacers and the heat shield on top and the two spacers on the back of the fireplace. The spacers and the heat shield are in the firebox of the fireplace and the scr...

  • Page 37

    Fp12 mundo ‐ installation and operation manual 37 6.3.1.1 raised base installation of more than 4" (r value for the hearth extension not required) the fp12 mundo may be installed directly on the floor or on a raised combustible or non combustible base. If the fireplace is elevated more than 4" ( b )...

  • Page 38

    38 fp12 mundo ‐ installation and operation manual.

  • Page 39

    Fp12 mundo ‐ installation and operation manual 39 in the case where ( f ) would be equal to 4", it is suggested that the sheet metal between the base of the fireplace and floor be in one piece..

  • Page 40

    40 fp12 mundo ‐ installation and operation manual 6.3.1.2 on the floor or on a raised base of less than 4" installation (r value for the hearth extension required) in the case where the fireplace is installed directly on the floor or on a raised base of less than 4", an r value for the hearth extens...

  • Page 41

    Fp12 mundo ‐ installation and operation manual 41 a non ‐ combustible floor protection with r value insulation equal to or greater than 1.00 must be installed in front of the unit. For more details see section 6.3.2: minimum heart extension requirements . The use of an r value is convenient when mor...

  • Page 42

    42 fp12 mundo ‐ installation and operation manual thermal characteristics of common floor protection materials* material conductivity (k) per inch resistance (r) per inch thickness micore ® 160 0.39 2.54 micore ® 300 0.49 2.06 durock ® 1.92 0.52 hardibacker ® 1.95 0.51 hardibacker ® 500 2.3 0.44 won...

  • Page 43

    Fp12 mundo ‐ installation and operation manual 43 clearances a 18" (457 mm)* b 41.5" (1054 mm) c 8" (203 mm) *on a raised base installation of more than 4", a non ‐ combustible hearth extension floor area must extend at least 16" (406 mm) in front of the hearth..

  • Page 44

    44 fp12 mundo ‐ installation and operation manual 6.3.3 framing, facing, mantel, and combustible shelf 6.3.3.1 framing the construction of the framing, facing, and mantel must be in accordance with the standards and the following illustrations: a. Frame the sides and back of the fireplace using 2" ×...

  • Page 45

    Fp12 mundo ‐ installation and operation manual 45 wall finish behind the fireplace’s faceplate installation clearances a 4 7/8" (124 mm) b* 8" (203 mm) c* 5" (127 mm) d* 80" (2032 mm) measurements e* 37 3/4" (959 mm) f* 24 3/4" (630 mm) g 1 1/2" (39 mm) max *when drywall panels or any other finishin...

  • Page 46

    46 fp12 mundo ‐ installation and operation manual see appendix 4: installing the mandatory adapter for fresh air intake kit (j). Fresh air intake kit (j) installation legend combustible material allowed in this area non ‐ combustible material only in this area minimum measurements for fresh air inta...

  • Page 47

    Fp12 mundo ‐ installation and operation manual 47 clearances ** k* 53 3/8" (1356 mm) l* 75 1/2" (1918 mm) *when drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. **values k and l are minimum measurements. They ma...

  • Page 48

    48 fp12 mundo ‐ installation and operation manual clearances a 3" (76 mm) maximum b 5 5/8" (143 mm) minimum c 24" (610 mm) minimum 6.3.3.2 facing non ‐ combustible material such as brick, stone or ceramic tile may be in contact with the fireplace decorative frame. Note that if you ever needed to rem...

  • Page 49

    Fp12 mundo ‐ installation and operation manual 49 a = fireplace b = hot air register c* d e f g 80" 1½" minimum 8" minimum 1½" minimum 12" minimum *must be measured from the base of the fireplace and not from the floor. Legend combustible material allowed in this area non ‐ combustible material only...

  • Page 50

    50 fp12 mundo ‐ installation and operation manual a = fireplace b = hot air register c* d e f 80" 8" minimum 8" minimum 12" minimum *must be measured from the base of the fireplace and not from the floor..

  • Page 51

    Fp12 mundo ‐ installation and operation manual 51 6.3.3.3 compliance of a combustible mantel shelf the installation of the combustible shelf is permitted. Refer to figure 15 in order to locate the safe location. The shelf shall have a depth (c) up to 12 "(305 mm) and shall be installed 48" (1219 mm)...

  • Page 52: Clearances

    52 fp12 mundo ‐ installation and operation manual 7 clearances to combustible material the clearances shown in this section have been determined by test according to procedures set out in safety standards ulc s610 (canada) and ul127 (u.S.A.). When the fireplace is installed so that its surfaces are ...

  • Page 53: The

    Fp12 mundo ‐ installation and operation manual 53 8 the venting system 8.1 general the venting system, acts as the engine that drives your wood heating system. Even the best fireplace will not function safely and efficiently as intended if it is not connected to a suitable chimney. The heat in the f...

  • Page 54

    54 fp12 mundo ‐ installation and operation manual there are two reasons why the chimney in the house at right will cold backdraft when it is cold outside and there is no fire burning in the fireplace. First, the chimney runs up the outside of the house, so the air in it is colder and denser than the...

  • Page 55

    Fp12 mundo ‐ installation and operation manual 55 10. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2" (50 mm) minimum clearance between the chimney and any combustible materials. Do not fill this 2 space with insulation or any other combu...

  • Page 56

    56 fp12 mundo ‐ installation and operation manual 12. For installations where more than one chimney is located in the same non ‐ chase or within the same area, we suggest that their terminations be separated by at least 16" (410 mm) horizontally, and 18" (460 mm) vertically. This separation is to pr...

  • Page 57

    Fp12 mundo ‐ installation and operation manual 57 8.6 chimney installation instructions always refer to the chimney manufacturer’s installation manual to ensure a safe installation. Some non ‐ illustrated parts may be required. 8.6.1 examples of typical chimney installation a to insure a good draft,...

  • Page 58

    58 fp12 mundo ‐ installation and operation manual direct installation exterior offset installation.

  • Page 59

    Fp12 mundo ‐ installation and operation manual 59 interior offset installation connection to a masonry chimney 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb bob to line up the center of the holes. Make sure that the size of the floor and ceiling h...

  • Page 60

    60 fp12 mundo ‐ installation and operation manual 2. From below, install a firestop (a) supplied by the chimney manufacturer in each ceiling/floor separation through which the chimney will pass. At the attic level, install a radiation shield from above (c). 3. Follow the chimney’s manufacturers’ ins...

  • Page 61

    Fp12 mundo ‐ installation and operation manual 61 8.6.2 offset chimney installation table 1 ‐ the minimum system height when using elbows is: fireplace model fp12 mundo chimney model all models vertical installation 15 ft. (4.6 m) two (2) elbows 15 ft. (4.6 m) four (4) elbows 17 ft. (5.2 m) after re...

  • Page 62

    62 fp12 mundo ‐ installation and operation manual table 2 ‐ listed chimneys for your fp12 mundo warning: in every case, the chimney must start with a 6'' diameter anchor plate secured to the fireplace. *this fireplace may be installed with a 7 ‐ inch chimney from “security chimney” as indicated it t...

  • Page 63

    Fp12 mundo ‐ installation and operation manual 63 reference in figure bellow. Parts required. (the numbers in brackets are the parts numbers used by security chimneys) inner diameter 6 ″ inner diameter 7 ″ 1 ″ insulation (asht+) 2 ″ insulation (s2100+) 1 ″ insulation (asht+) 2 ″ insulation (s2100+) ...

  • Page 64

    64 fp12 mundo ‐ installation and operation manual table 3 – list of mandatory components chimney manufacturer mandatory components type/brand security chimney rafter protector at the roof level if chimney is enclosed at the attic level. Requires insulated attic radiation shield unless chimney is enc...

  • Page 65

    Fp12 mundo ‐ installation and operation manual 65 8.7 angled wall radiation shield when passing through a combustible wall with the chimney at a 30 or 45 angle (30 or 45 in canada and 30 only in the usa), an angled firestop or wall radiation shield provided by the chimney manufacturer must be instal...

  • Page 66

    66 fp12 mundo ‐ installation and operation manual 8.8.2 universal offset support this support is used to support the chimney above an offset. When the chimney offset is used to pass through a wall, this support may be used on the wall to support the chimney. For offset support installation, refer to...

  • Page 67

    Fp12 mundo ‐ installation and operation manual 67 follow these steps: 1. Position the fireplace in its location. Temporarily install the elbow or chimney section (a) on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney. 2....

  • Page 68: Appendix

    68 fp12 mundo ‐ installation and operation manual appendix 1: heat distribution systems installation different heat distribution systems can be installed with the fp12 mundo: one of these two heat distribution systems (sold separately) is mandatory on the fp12 mundo: gravity kit ‐ traditional style ...

  • Page 69

    Fp12 mundo ‐ installation and operation manual 69 dimensions of hot air outlet frame with elbow dimensions of hot air outlet decorative grille with elbow.

  • Page 70

    70 fp12 mundo ‐ installation and operation manual the hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more heat out of the higher grilles..

  • Page 71

    Fp12 mundo ‐ installation and operation manual 71 1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia. Holes on top of the fireplace. Then, cut and remove the insulation in order to obtain two 8" dia. Openings. Then, remove the plates closing up the...

  • Page 72

    72 fp12 mundo ‐ installation and operation manual 3. Secure the ducting (a) to the 90° elbows (e) with self ‐ tapping screws (3 per elbow). Insert the frames (f) in the elbow (e). Set hot air outlets frames behind the non ‐ combustible materiel and secure to the wall with screws. Secure the frames (...

  • Page 73

    Fp12 mundo ‐ installation and operation manual 73 7. When passing through a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be in accordance with the duct manufacturer’s instructions..

  • Page 74

    74 fp12 mundo ‐ installation and operation manual c d 12’’ minimum 8’’ minimum c d 12’’ minimum 60’’ minimum clearances above are good for the gravity kit ‐ traditional style (ac01375) and for the gravity kit ‐ modern style (ac01385). 8. Do not connect the hot air ducts to a central heating system. ...

  • Page 75

    Fp12 mundo ‐ installation and operation manual 75 gravity kit ‐ modern style (ac01385) the kit includes: - decorative plate (a) - adjustable frame (b) - heat distribution box (c) - 6 x steel brackets (d) with fastening screws (e) and self ‐ tapping screws (f) parts not included in the kit: - 2x 8” r...

  • Page 76

    76 fp12 mundo ‐ installation and operation manual dimensions of heat distribution box: dimensions of adjustable decorative plate:.

  • Page 77

    Fp12 mundo ‐ installation and operation manual 77 dimensions of assembeled heat distribution box and adjustable decorative plate: the duct system must be installed respecting the following: 1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia. Holes ...

  • Page 78

    78 fp12 mundo ‐ installation and operation manual 2. Secure the 6 steel brackets (b) with 6 screws provided (c) on top of the fireplace (3 for each ducting). Insert the ducting (a) (not provided) into each opening and secure it in place using the steel brackets (b) installed previously with 6 other ...

  • Page 79

    Fp12 mundo ‐ installation and operation manual 79 3. Secure the ducting (a) to the heat distribution box (e) with self ‐ tapping screws (3 per ducting). Insert the adjustable frame (f) in the heat distribution box, press it against the non ‐ combustible finishing material and secure with 4 screws in...

  • Page 80

    80 fp12 mundo ‐ installation and operation manual the optional forced air distribution kit (not tested to epa standards) (ac01363)* it is possible to connect a forced air distribution kit (ac01363) on the left side (1) or on the back (2) of the fp12 mundo. This kit allows distributing heat to anothe...

  • Page 81: Appendix

    Fp12 mundo ‐ installation and operation manual 81 appendix 2: the optional finishing trim installation (va10fl02) finishing trim dimensions: installation: set the finishing trim around the fireplace frame. If desired, the back of the finishing trim may be glued..

  • Page 82: Appendix

    82 fp12 mundo ‐ installation and operation manual appendix 3: installing the optional fire screen (ac01364) 1. Bring the fire screen close to the door opening. 2. Insert the fire screen hinge pins in the holes on the door hinges. Close the fire screen and press firmly against the door opening. Accro...

  • Page 83: Appendix

    Fp12 mundo ‐ installation and operation manual 83 appendix 4: installing the mandatory adapter for fresh air intake kit during operation, the fireplace requires fresh air for combustion. The fp12 mundo requires the installation of a fresh air intake kit. The insulated flexible pipe length should be ...

  • Page 84

    84 fp12 mundo ‐ installation and operation manual secure the fresh air intake adapter (a) on the fireplace jacket using the 4 screws provided with the kit. Then, install the flexible pipe* (c) (not supplied) to the fresh air intake adapter (a) using one of the adjustable pipe clamps (b) . Secure the...

  • Page 85

    Fp12 mundo ‐ installation and operation manual 85 to complete the installation, make a hole of1/4" to 1/2" (6 mm à 13 mm) bigger than the insulate pipe diameter in the outside wall of the house at the chosen location. From outside, place the outside air inlet cap in the hole (open side down) and fas...

  • Page 86: Appendix

    86 fp12 mundo ‐ installation and operation manual appendix 5: installation of secondary air tubes and baffle removable parts a air tubes (x4) b cotter pins (x4) c c ‐ cast baffle (x1) d baffle insulation (x1) e baffle insulation weight (x1) 1. Using a ratchet key and a torx socket (t ‐ 30), unscrew ...

  • Page 87

    Fp12 mundo ‐ installation and operation manual 87 2. Remove the floor refractory slab (c). 3. Using a power screwdriver and a 5/16" hexagonal socket, remove the slab holder (d) and the left refractory slab (e)..

  • Page 88

    88 fp12 mundo ‐ installation and operation manual 4. Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole. Then, lift and push the tube towards the right inside the hole in the right channel. 5. Align the notch in the left end of the t...

  • Page 89: Model

    Fp12 mundo ‐ installation and operation manual 89 6. Insert a cotter pin in the last hole on the right side of the tube. Then bend the tabs on the pin to keep in place. 7. Repeat steps 4, 5 and 6 for the two tubes in the back then install the baffle. Then, install the two front tubes. 8. To remove t...

  • Page 90: Appendix

    90 fp12 mundo ‐ installation and operation manual appendix 6: exploded diagram and parts list.

  • Page 91

    Fp12 mundo ‐ installation and operation manual 91 important : this is dated information. When requesting service or replacement parts for your stove, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability. Contact an auth...

  • Page 92

    92 fp12 mundo ‐ installation and operation manual # item description qty 39 pl63767 side front spacer 4 40 pl63768 side rear spacer 2 41 pl53065 rear spacer 2 42 22155 refractory left stone 1 43 22154 refractory right stone 1 44 22153 refractory back stone 1 45 22137 floor refractory slab 1 46 24166...

  • Page 93

    Fp12 mundo ‐ installation and operation manual 93 refractory slabs replacement the intense heat of the fire will normally cause hairline cracks in the refractory slabs. These cracks can be minimized by proper curing as described in “first fires”. They will not normally diminish the effectiveness of ...

  • Page 94

    94 fp12 mundo ‐ installation and operation manual 3 ‐ using a power screwdriver and a 5/16” hexagonal socket, remove the slab holders (d) and the refractory slabs (e) and (f). 4 ‐ remove the rear refractory slab (g). To install new refractory slabs, follow the above steps in reverse..

  • Page 95: Valcourt

    Fp12 mundo ‐ installation and operation manual 95 valcourt limited lifetime warranty the warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipme...