Valley Comfort Systems Blaze King 6003T Installation And Operating Instructions Manual - Installation Instructions
The Tuscany
by Blaze King
Owners Installation and Operation Manual
OM-6003T
Page 9
DATE PRINTED: 4/7/11
Version 1.08 SIT
CLEARANCES TO COMBUSTIBLES
Minimum clearances listed above must be
maintained. Also ensure that you have left
clearance for servicing and that that the proposed
termination location is correct.
LOCATING YOUR STOVE
IMPORTANT:
This appliance's venting system is
room sealed, which means that there should be no
provision to allow room air to be used in the com-
bustion process.
VENTING
Note: Only venting systems listed in this
manual may be used with the Tuscany. The
Simpson
Duravent
GS
®,
American
Metal
Products and Security vent systems are listed
for use with the Tuscany. See the next page for
a full parts list.
PLANNING YOUR VENT INSTALLATION
This type of direct vent system may terminate in
one of two ways: Vertical termination using a vent
cap, or horizontally using a wall termination. There
are limitations to the vertical and/or horizontal
lengths. When calculating the length of the vent
pipe from the outlet of the appliance to termination,
allow for ceiling thickness, vertical rise in the attic
or second story and sufficient vertical height above
the roof.
Fire stops are required at each floor level the vent
passes through.
When carrying out vertical installations that require
45° elbows add additional pipe to allow for the
offset.
Installation Instructions
MODEL TUSCANY
A
Side Wall to unit side
11” (275mm)
B
Back wall to unit back
4” (50mm)
C Corner to side wall
2” (100mm)
Installation showing 36” section
and 14” Snorkel
36” section. Note: duravent also
supplies adjustable sections to
allow adjustment of section length
to suit installation (see parts list)
C/L
Cut 10” square hole.
Measure from floor
finish to center—
20”
Follow venting manufacturer ‘s instructions and adhere to all
local codes, authorities and standards for your installation.
2” minimum. Install to
suit. Use adjustable
section if required
Corner install showing 45° elbow either straight off back of
unit or in mid section with snorkel kit.
REAR VENT—SNORKEL TERMINATION
MINIMUM VERTICAL RISE
36” Using American Metal snorkel
(part #4D36S)
MAXIMUM HORIZONTAL RUN 3 ft When using 36” Snorkel.
One 45° elbow may be used for
corner installs.
Installation showing 36” section
and 36” Snorkel
36” section. Note: duravent also
supplies adjustable sections to
allow adjustment of section length
to suit installation (see parts list)
36” Snorkel. American
Metal #4D36S
C/L
Cut 10” square hole.
Measure from floor
finish to center—
20”
Follow venting manufacturer ‘s instructions and adhere to all
local codes, authorities and standards for your installation.