Valley Comfort Systems MP80 Installation and operation manual

Other manuals for MP80: Operation & installation manual
Manual is about: SOLID FUEL WOOD FURNACE For use as an add-on to electric, gas, or oil furnaces or and independent wood furnace when equipped with a blower.

Summary of MP80

  • Page 1

    Mp80.Pub version 1.07 1 mp80 installation and operation manual valley comfort systems inc. 1290 commercial way penticton, b.C. V2a 3h5 (250) 493-7444 www.Blazeking.Com email: sales@blazeking.Com read thoroughly and comply with all local codes and regulations mp80 solid fuel furnace for use as an add...

  • Page 2

    Mp80.Pub version 1.07 2.

  • Page 3

    Mp80.Pub version 1.07 3 index warranty 4-7 specifications 8 safety precautions 9 operations 10 lighting instructions 10 wood types 11 reloading 11 creosote 12 maintenance 13 gasket (door) 11 installation instructions 14 parts included 14 optional equiptment 14 installation options 14 typical install...

  • Page 4: Warranty

    Mp80.Pub version 1.07 4 warranty blaze king wood limited warranty blaze king and its respective brands extend the following warranty for wood fired appliances purchased from an authorized blaze king dealer and installed in the united states of america or canada. Warranty starts with date of purchase...

  • Page 5

    Mp80.Pub version 1.07 5 blaze king wood limited 5 year warranty blaze king is the manufacturer of the blaze king line of heating products. At blaze king, our commitment to the highest level of quality and customer service is the most important thing we do. Each blaze king stove is built on a traditi...

  • Page 6

    Mp80.Pub version 1.07 6 exclusions and limitations: 1. This warranty does not cover tarnish, discoloration or wear on the plated surfaces painted finishes will change colour after initial firing and will continue to change through the lifetime of the stove. This is normal occurrence for all high tem...

  • Page 7

    Mp80.Pub version 1.07 7 21. No dealer, distributor, or similar person has the authority to represent or warrant blaze king products beyond the terms contained within the limited warranty. Blaze king assumes no liability for such warranties or representations. 22. Blaze king will not cover the cost o...

  • Page 8: Specifications

    Mp80.Pub version 1.07 8 specifications model mp80 rating 80,000 btu. Nominal height 35 width 21 length 37 flue collar 6" id flue pipe center to bottom 26 1/2" recommended flue pressure .03" water column (draft) hot air plenum opening 30 5/8" l x 18" w fire door opening 12" x 13" firebox length 26" w...

  • Page 9: Safety

    Mp80.Pub version 1.07 9 safety precautions - comply with all local codes and regulations. - never operate a furnace that has been improperly installed. - do not use chemicals or fluids to start or freshen a fire. Keep all flammable fluids well away from the furnace. - do not burn garbage, gasoline, ...

  • Page 10: Operating Instructions

    Mp80.Pub version 1.07 10 congratulations on your choice of a wood furnace from valley comfort. We thank you for the confidence you have placed in us. A word about valley comfort -- in 1953 when most folks were excited about getting rid of their wood burning appliances, a determined entrepreneur, pet...

  • Page 11

    Mp80.Pub version 1.07 11 what kind of wood there is an old idea that you should use some green wood to insure long burn times. This is wrong! Always remember, the dryer the wood the better. It takes a great deal of energy to evaporate the moisture contained in green wood and that energy will not be ...

  • Page 12

    Mp80.Pub version 1.07 12 creosote in any wood burning appliance, creosote can be a problem. The best way to handle it is to prevent or mini- mize it by proper firing methods. If creosote does occur you should understand its nature and have a plan to handle it. Always assure safety by having a clearl...

  • Page 13

    Mp80.Pub version 1.07 13 maintenance maintain fire door gaskets to ensure a tight seal. Use 7/8" replacement gasket. Glue is not necessary as high density gasket will fit tight and stay secure. Warning: do not operate this wood furnace if the door gasket is missing or damaged. Dangerous overfiring c...

  • Page 14: Installation Instructions

    Mp80.Pub version 1.07 14 installation instructions general please take time to read these instructions thoroughly. You have invested your money in a quality product. Too much haste now, could result in a faulty installation, and cause serious problems. In addition to these general installation instr...

  • Page 15

    Mp80.Pub version 1.07 15 mp80 hot air to house alternate hot air plenum gas, oil electric up flow furnace existing mp80 return air plenum hot air supply plenum counter/ flow gas electric or oil typical add on system layout (80fig1) wood counterflow installation requires note in this configuration sp...

  • Page 16

    Mp80.Pub version 1.07 16 cautions all installations must comply with local building safety codes. Installation shall be by a licensed, qualified mechanical installer experienced in heating equipment installations. The wood section must be vented into a chimney approved for solid fuel use be in good ...

  • Page 17

    Mp80.Pub version 1.07 17 note: after interconnect duct opening has been cut into the side of the mp80, insulation must be fastened back to the furnace cabinet all around the opening. Use the metal strips provided to hold the insulation tightly against the cabinet inside, to prevent the insulation fr...

  • Page 18

    Mp80.Pub version 1.07 18 location re flue the chimney must be an approved chimney for use with solid fuel fired appliances, be in good repair and be free from leaks and obstructions. If using a masonry chimney, it must meet the minimum standards of the building code of canada. The wood flue must alw...

  • Page 19

    Mp80.Pub version 1.07 19 chimney height requirements regardless of whether you use a masonry chimney or a listed metal chimney it must be the required height above the roof or other obstructions. The code requires the chimney to be at least 3 feet higher than the highest point where is passed throug...

  • Page 20

    Mp80.Pub version 1.07 20 fan limit installation using the bracket provided, install the fan limit and junction box assembly onto the warm air plenum, above and to the right of the firebox fuel door, as illustrated in fig 2. All 120vac wiring must be routed on the outside of the cabinet surface. Inst...

  • Page 21

    Mp80.Pub version 1.07 21 add-on to oil furnace the mp80 may be connected to an oil furnace having a rated input of up to 1.2 usgph. Minimum blower capacity must be at least 900 cfm.. A regular upflow oil furnace may be used and connected as per fig. 1on page 15. The mp80 can be located on either sid...

  • Page 22

    Mp80.Pub version 1.07 22 diagram 6 typical wiring for wood / gas, wood / oil or wood/ electric combinations independent wood furnace when installed with a blower cabinet mounted on either side the mp80 becomes an inde- pendent wood only furnace. The blower must have a minimum 900 cfm. Capacity. In t...

  • Page 23

    Mp80.Pub version 1.07 23 diagram 8a wiring connections when using electrical furnace with w1,r,c&g connections. You must connect the alternate furnace thermostat through the interlock limit switch to provide interlock lockout of the alternate furnace when the wood plenum rises above 150 degrees..

  • Page 24

    Mp80.Pub version 1.07 24 diagram 7 wiring as an independent forced air wood furnace equipped with a vb1000 blower when installing in a stand-alone configura- tion with a vb1000 blower. Only 2 out of the three limit switches are used. The middle limit is the operating limit and the right limit switch...

  • Page 25

    Mp80.Pub version 1.07 25 vb1000 valley comfort blower specifications 1 29/32 " 6 3/16 " 19 7/16 " 13 1/4 " 1 1 1 3 /1 6 " 19 15 /16 " 24" 22" 17 15 /16 " 3 /4 " 1" 1" this opening attaches to the furnace 1 3 2 3 /3 2 " this opening attaches to the plenum 1/3 hp 110v motor adjustable from 900cfm to 1...

  • Page 26

    Mp80.Pub version 1.07 26.