  • Page 1

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 1 owners manual model vc120 solid fuel furnace for use as an add-on to electric, gas, or oil furnaces or an independent wood furnace when equipped with a blower. Save these instructions www.Valleycomfort.C...

  • Page 2: Specifications

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 2 revised: october 14 th , 2003 specifications model vc120 rating 120,000 btu. Nominal height 50 1/2" width 29 1/2" length 36" flue collar 7" i.D. Flue pipe center to rear 5 1/2" recommended flue pressure ...

  • Page 3: Safety Precautions

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 3 safety precautions comply with all local codes and regulations. Never operate a furnace that has been improperly installed. Do not use chemicals or fluids to start or freshen a fire. Keep all flammable f...

  • Page 4

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 4 congratulations on your choice of a wood furnace from valley comfort. We thank you for the confidence you have placed in us. A word about valley comfort-- in 1953 when most folks were excited about getti...

  • Page 5

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 5 what kind of wood? There is an old idea that you should use some green wood to insure long burn times. This is wrong! Always remember, the dryer the wood the better it is. It takes a great deal of energy...

  • Page 6

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 6 operations (contd) • during a power failure, use extreme caution not to over fire. Do not fill wood above the top of the liner bricks. The furnace is designed as a forced air furnace and excess firing wi...

  • Page 7

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 7 creosote in any wood-burning appliance, creosote can be a problem. The best way to handle it is to prevent or minimize it by proper firing methods. If it does occur you should understand its nature and h...

  • Page 8

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 8.

  • Page 9

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 9 maintenance maintain fire door gaskets to ensure a tight seal. Use 1" replacement gasket. Warning: do not operate this wood furnace if the door gasket is missing or damaged. Dangerous overfiring can occu...

  • Page 10

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 10 installation instructions general please take time to read these instructions thoroughly. You have invested your money in a quality product. However, too much haste now, could result in a faulty install...

  • Page 11

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 11 cautions 1. All installations must comply with local building safety codes. 2. Installation shall be by a licensed, qualified mechanical installer experienced in heating equipment installations. 3. The ...

  • Page 12

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 12 typical installation illustration pressure loss before any changes are made to the existing furnace system you must establish the working parameters of that system. You can then insure that addition of ...

  • Page 13

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 13 combustion air insure adequate combustion air allowing for all other exhausting type appliances in the dwelling (range hoods, dryers, etc). Outside combustion air can be connected directly to the combus...

  • Page 14

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 14 chimney height requirements regardless of whether you use a masonry chimney or a listed metal chimney, suitable for use with solid wood fuels, it must be the required height above the roof or other obst...

  • Page 15

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 15 electrical general all wiring on the vc120 shall be fastened to the insulated cabinet surfaces only, to prevent overheating by direct contact with firebox components. Electrical installation must be don...

  • Page 16

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 16 brick and baffle installation firebox bricks and baffle components are shipped separately to reduce unit weight and ease installations. Never operate the furnace without first installing all bricks and ...

  • Page 17

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 17 install firebox liner brick in the sequence indicated by number in the following diagram. (fig 3) add-on to electric furnace the vc120 may be added to an electric furnace with heating capacity between 1...

  • Page 18

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 18 electrical connections wood/electric this figure is not a physical representation of your electrical connections. Limit switches and relays may be laid-out differently than shown. The words and letters ...

  • Page 19: Add-On To Gas Furnace

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 19 add-on to gas furnace the vc120 may be connected to a gas furnace having a rated input of up to 140,000 btu. Minimum blower capacity must be at least 900 cfm.. A counter flow gas furnace may be used wit...

  • Page 20

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 20 electrical connections wood/oil wood/gas * note a: you must cut or remove the jumper between the fan and limit sides of the wood limit control wiring diagram for the connection of vc120 to an alternativ...

  • Page 21: Independent Wood Furnace

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 21 independent wood furnace when installed with a blower cabinet mounted on either side the vc120 becomes an independent wood only furnace. The blower must have a minimum 900 cfm. Capacity (1/3 hp.). In th...

  • Page 22: Cautions:

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 22 cautions: 1. The coil and system must be installed by a qualified tradesman who is familiar with domestic hot water systems. 2. Adhere to all local building codes during the installation. 3. Do not fire...

  • Page 23: (Stand Alone Applications)

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 23 1 2 9 /3 2 " 6 3/16" 19 7/16 " 13 1/4 " 1 1 1 3 /1 6 " 19 15 /16 " 24" 22" 17 15 /16 " 3 /4 " 1" 1" this opening attaches to the furnace 1 3 2 3 /3 2 " this opening attaches to the plenum • 1/3 hp 110v ...

  • Page 24

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 24 note: a light layer of stove cement may be required to ensure 100% contact between the firebox and coil domestic water coil installation on vc120 warm line out to upper tank inlet cool line in from lowe...

  • Page 25

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 25 valley comfort systems inc. Limited warranty - vc120 warning: to validate this warranty you must complete and return the warranty card within 20 days of the date of purchase. What the warranty covers: t...

  • Page 26: Warning

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 26 valley comfort systems inc limited warranty - vc120 misuse of furnace nullifies warranty: the above warranty is conditional upon the proper installation and use of the furnace according to the manufactu...

  • Page 27

    Valley comfort systems inc. 1290 commercial way, penticton, b.C., v2a 3h5, (250) 493-7444 page 27 index add-on furnace .................................................................11 add-on to electric furnace ................................16 add-on to gas furnace.................................