Vallox TSK Multi 80 MC R Manual - page 10
10
TECHNIC
AL SPECIFIC
ATIONS
Supply/extract air volumes
Volume flow rate (dm3/s)
Pressure loss in ducts. T
otal pressure (P
a)
Air flow
measurement
points
Measurement points after
the outlet collar. The fan
curves indicate the total
pressure accounted for by
duct losses.
FAN INPUT POWER
Fan speeds
With the SC control
panel (V)
Extract air flow
(50 Pa) dm3/s
Combined input power
of the fans (W)
3
-
12
4
9
17
5
27
25
6
38
34
7
52
47
8
67
68
9
78
95
10
90
125
11.3
99
165
TECHNICAL SPECIFICATIONS
Product title
Vallox TSK Multi 80 MC R
Vallox TSK Multi 80 MC L
Product number
3478000
3478100
HVAC code
7912024
7912025
Air volumes Supply air
Extract air
76dm3/s, 100Pa
93dm3/s, 100Pa
Electrical connection
230V, 50Hz 8.8A power plug
Enclosure protection class
IP34
Post-heating radiator
Electric, 900W
Preheating radiator
–
Additional heating radiator
Electric, 900W
Fans Supply air
Extract air
0.071kW 0.5 A EC
0.071kW 0.5 A EC
Specific energy consumption (SEC)
in a cold climate
in a temperate climate
A+
B
Operating efficiencies Annual
efficiency
Supply air efficiency
Specific Fan Power
(SFP)
75% A+
85%
0.9 (38dm3/s) A
Filters
Supply air
Extract air
G4 + F7
G4
Heat recovery bypass
Automatic
Dimensions (w x h x d) and weight
1026 x 293 x 626, 58.5 kg
350
300
250
200
150
100
50
0
0
10
20
30
40
50
60
70
80
90
100
110
SFP, kW / (m/s) 2,0
SFP, kW / (m/s) 1,5
SFP, kW / (m/s) 1,0
S 3,0 V
S 4,0 V
E 3,0 V
E 4,0 V
S 5,0 V
S 6,0 V
S 7,0 V
S 8,0 V
S 9,0 V
S 10,0 V
S 11,3 V
E 5,0 V
E 6,0 V
E 7,0 V
E 8,0 V
E 9,0 V
E 10,0 V
E 11,3 V
ED
SD
VALLOX TSK MULTI 80 MC
Supply air
View from above
2
1
2
4
3
1
3
4
Le
ft s
id
e
Rig
ht
s
id
e
Extract air
Combined input power of the fans (kW)
Airflow specified in the ventilation plan (m3/s)
SFP =
SFP rate (Specific Fan Power)
recommended value <2.0kW (m3/s)
ED and SD are examples of pressure loss
in the supply and extract air ducts.
S = supply air
E = extract air