Valor 1500INO (NG) Installation & Owners Manual

Other manuals for 1500INO (NG): Installation & Owner's Manual
Manual is about: DV ZC Gas Fireplace for Outdoor use

Summary of 1500INO (NG)

  • Page 1

    L1 s eries dv zc gas fireplace for outdoor use 1500ino (ng) & 1500ipo (lpg) installation & owner’s manual 4005171-01 ©2015, miles industries ltd. This manual contains instruc- tions to install the engine only. A front or trim kit is re- quired to install the engine. A barrier screen is provided with...

  • Page 2

    2 for the owner for the qualified installer the information contained in this installation manual is believed to be correct at the time of printing. Miles industries ltd. Reserves the right to change or modify any information or specifi cations without notice. Miles industries ltd. Grants no warrant...

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi ...

  • Page 6

    6 warning do not touch the glass while it is hot! Let the fi replace cool fi rst before cleaning it. ! Caution be careful when using a hose or pressure washing to clean the areas around the fi replace. Never spray water directly at the fireplace! Cleaning around your fireplace your valor outdoor gas...

  • Page 7

    7 spring loaded window levers warning choking hazard! Ensure that the fi replace area is clear of fi reglass or vermiculite particles as these could be ingested by small children. Vacuum thoroughly around the fi replace area after cleaning. 3. Find the levers on each side of the window towards the t...

  • Page 8

    8 warning do not attempt to change the batter- ies while the fireplace is still hot! Let the fi replace cool fi rst before touching it. Caution do not use a screwdriver or other metallic object to remove the batteries from the battery box or the handset! This could cause a short circuit. Pilot flame...

  • Page 9

    9 warning do not attempt to touch the informa- tion card while the fireplace is still hot! Let the fi replace cool fi rst before touching it. Battery box receiver window the battery box is located on the bottom of the appliance behind the front panel. Info card window the info card is located behind...

  • Page 10

    10 wall switch gas valve battery box receiver gas valve window the battery box, receiver and gas valve are located on the bottom of the appliance behind the front panel. How to turn your fireplace off (including pilot) familiarize yourself with the wall swich operation before using your fi replace. ...

  • Page 11

    11 required kits* fuel beds (choose one) 1500dgs—decorative glass set 1505dwk—driftwood kit 1510dgm—decorative glass murano 1514rss—rock and shale set ceramic liners (choose one) 1515fbl—linear fluted black liner set 1520fsl—linear fluted sand liner set 1525rgl**—linear refl ective glass liner set (...

  • Page 12

    12 lighting instructions for your safety, read before lighting warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand or wall switch. Follow these ...

  • Page 13

    13 state of massachusetts carbon monoxide detector/vent terminal signage requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth...

  • Page 14

    14 (d) manufacturer requirements - gas equipment venting system not provided. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi es “special venting systems”, the following requirements s...

  • Page 15

    15 x ratings model n p gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 30,000 28,000 input minimum (btu/h) 18,000 18,500 manifold pressure (in w.C.) 4.0” 9.5” minimum supply pressure (in w.C.) 5” 11” maximum supply pressure (in w.C.) 10” 14” main burner injector marking 850 3...

  • Page 16

    16 overview fire on/off wall switch (20-foot wire length) (supplied) mantel—see mantel & hearth clearances note: this appliance must be installed in a weather protected environment—see location details on page 18. Hearth: not required. If used, must be minimum 4” below fi replace opening. S s s surr...

  • Page 17

    17 m in. 44-1/2” (1130 mm ) to t op o f c ement boar d m in. 43” ( 1092 mm ) () to underside o f header gas line access point zero clearance stand-offs header center line 6-5/8” dia. Venting field- convertible from top to rear outlet center of vent heat shield required for rear vent outlet applicati...

  • Page 18

    18 top view side view min. Required weatherproof overhang in front and at sides of fireplace is 1/2 of the height of the overhang measured from the base of the unit min. Required overhang outdoor fireplace installed in weatherproof enclosure 1 2 location location for the purposes of this installatio...

  • Page 19: Inside

    19 location min. Weatherproof overhang in front and at sides free standing structure with weatherproof overhang above weatherproof enclosure continuous insulated building envelope and weatherproof membrane is not interrupted by fireplace installation inside inside outside min. Weatherproof overhang ...

  • Page 20

    20 0 2” 4” 6” 8” 10” 12” bottom of appliance face of 1/2” thick non-combustible cement board do not put furniture or objects within 36” (914 mm) of front of appliance min. Required weatherproof overhang allowable combustible projection combustible mantel projection (from face of cement board) combus...

  • Page 21

    21 39-11/16” fireplace opening wall min. 4” to wall or combustible mantel leg face of finished wall fireplace combustible sidewall / mantel leg—top view mantel & hearth clearances qualified installer.

  • Page 22

    22 20” 43” 46” 1/2” thick non-combustible cement board required above, on each side and below engine opening (not supplied) note: height of cavity may be affected by vent configuration - see page 26 between underside of header and bottom of firebox no hearth required. If using a hearth, see page 22....

  • Page 23: Partial Shelf, Top Outlet

    23 43” (1093 mm) t o underside of c ombustible ca vit y min. 1” (25.4 mm) clearance to combustibles around vertical vent pipe approx. 10-3/4” (274 mm) from back surface of wall finish to front surface of appliance case w/no vent offset 15-1/16” (383 mm) 14-1/2” (369 mm) 9-3/8” (238 mm) 19-1/4” (489 ...

  • Page 24: Partial Shelf, Top Outlet

    24 43” (1093 mm) t o underside of c ombustible ca vit y min. 1” (25.4 mm) clearance to combustibles around vertical vent pipe note - vent elbow in cavity requires 9” (229 mm) clearance above when less than 12” (305 mm) vertical pipe is used; otherwise elbow requires 3” (77 mm) top clearance. Approx....

  • Page 25: Full Shelf, Rear Outlet

    25 heat shield 20” (508 mm) from the font surface of the wall finish to the front surface of appliance case for venting clearances, see venting chart section 43” (1093 mm) t o underside of c ombustible ca vit y 14-1/2” (369 mm) 9-3/8” (238 mm) 19-1/4” (489 mm) fireplace opening full shelf, rear outl...

  • Page 26

    26 10” (254 mm) 10” (254 mm) align the vent center to the center of the frame venting top or rear outlet this unit is supplied with a top vent outlet which can be fi eld-converted to a rear vent outlet. See installation section for more information. Vent material this unit is approved for installati...

  • Page 27

    27 horizontal termination 2-piece wall thimble pipe length horizontal termination 2-piece wall thimble pipe length pipe length pipe length pipe length 90˚ elbow ceiling firestop attic firestop attic insulation shield flashing storm collar vertical termination co-axial venting typical co-axial ventin...

  • Page 28

    28 2 4 6 8 10 12 14 16 18 20 vertical rise (ft) horizontal run (ft) 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 4 x 90º elbows maximum (or equivalent) position #5 example 1 no installation v2 v1 v3 h2 h1 max. 24” pipe if no vertical rise is used 45° elbow take-off supplied with unit 1”...

  • Page 29

    29 position #1 position #2 position #3 position #4 position #5 inside fi rebox—roof venting port restrictor the restrictor is located in the roof of the fi rebox hidden above the top liner panel. Adjust the restrictor before installation of the top liner panel. Should subsequent adjustment be requir...

  • Page 30

    30 v g a min. 72” max. 72” alcove detail (open on one side) normal ceiling/ soffi t clearances apply. Key vent terminal locations - minimum distances minimum clearance inches cm a clearance above grade, verandah, porch, deck or balcony 12 30 b clearance to window or door leading to inside space that...

  • Page 31

    31 roof pitch minimum "h" (feet) flat to 7/12 1' over 7/12 to 8/12 1.5' over 8/12 to 9/12 2’ over 9/12 to 10/12 2.5’ over 10/12 to 11/12 3.25’ over 11/12 to 12/12 4’ over 12/12 to 14/12 5’ overhang should not extend beyond vent if within 48” of termination cap horizontal overhang vertical wall min. ...

  • Page 32

    32 fold lines only qualifi ed licensed or trained personnel should install this appliance. Installation unpack appliance beware of sharp edges! Wear gloves! 1. Remove the cardboard wrapping and the wood pallet from the appliance and discard. 2. Unpack any loose items from around the appliance. 3. Re...

  • Page 33

    33 non- combustible m aterials onl y read instruc tions m atÉria ux inc ombustibles seulement consul tez le guide d ’inst alla tion fl ush front face of appliance mounting tabs (4) appliance fl ush to framing installation remove top outlet (6 screws) remove heat shield (3 screws) remove heat shield ...

  • Page 34

    34 1/2” (13mm) thick non-combustible cement board 1-3/4” (45 mm) 1” (25 mm) 1/4” (7 mm) note: when installing the 1555 1” trim, allow space for the barrier screen lower tabs by notching the cement board/wall finish at the bottom of the opening (same dimensions on both sides) gypsum board up to perim...

  • Page 35

    35 section views window frame bottom railing remove window the window is held in place by a spring-loaded lever on each side. 1. To remove the window, locate the levers on each side of the window towards the top. Using your fi nger, pull the lever towards you and unhook it from the window frame brac...

  • Page 36

    36 x 3-3/4” (95 mm) gas line access hole 2-1/2” (64 mm) diam. 4” (102 mm) front of the appliance installation set-up gas supply the gas supply inlet con- nection is a 3/8” npt male connector located on the left hand side of the fi rebox. The unit is supplied with a stainless steel fl ex line to allo...

  • Page 37

    37 top underside (fi re side) install liners the liners install in the manner outlined below with the exception of the 1525rgl—refl ective glass liners: see instructions supplied with the liners. Unpack the liner panels carefully. 1. Inside the fi rebox, on the top of each side, release the screw of...

  • Page 38

    38 install driftwood kit 1505dwk material required • black steel platform (supplied with appliance) • small container to distribute vermiculite (not included) • driftwood kit containing: ◊ 5 logs ◊ 6 pebbles ◊ 1 bag of vermiculite installation platform carefully unpack the kit. 1. Install the steel ...

  • Page 39

    39 logs installed logs and rocks each log has pegs to help you locate them on the platform. Install the logs as shown below. 1. Place the rear log in the center of the fi rebox at the rear. Note: there are two holes for the left peg of this log. Place the log’s left peg in the front hole for natural...

  • Page 40

    40 warning choking hazard! Ensure that the fi replace area is clear of vermiculite particles as these could be ingested by small children. Vacuum area after installation. 6. Some vermiculite may be added outside the burner on the platform if desired. 7. Place the rocks on the platform as shown below...

  • Page 41

    41 warning choking hazard! Ensure that the fi replace area is clear of fi reglass particles as these could be ingested by small children. Vacuum area after installation. ! Installed glass plate 2. Install the glass plate on the platform, the textured side underneath and the smooth side on top. The p...

  • Page 42

    42 warning choking hazard! Ensure that the fi replace area is clear of fi reglass particles as these could be ingested by small children. Vacuum area after installation. ! Installed tray edge of tray fl ush with edge of fi rebox small round hole at rear left of fi rebox pilot shield pilot shield fir...

  • Page 43

    43 installation install rocks & shale set 1514rss material required • black steel platform (supplied with appliance) • small container to distribute shale (not supplied) • rock & shale set, which contains: ◊ 1/2lb-bag of 3/4” grey shale ◊ 1/2lb-bag of 3/4” black shale ◊ 5 twigs ◊ 29 rocks installati...

  • Page 44

    44 installation 2. Mix the black and grey shale pieces and spread them in one layer thick on top of the burner around the three rocks. Do not overfi ll! 3. Install the rocks around the shale bed according to the image shown below. Note: some of the rocks may overhang slightly over the burner edge. 4...

  • Page 45

    45 installation window frame bottom railing section views refi t window 1. To refi t the window, place it in its bottom railing. Ensure there is no glass or vermiculite particles in the bottom railing. 2. Push the top of the window frame against the fi rebox. 3. While you hold it, pull the side leve...

  • Page 46

    46 the receiver and battery box are located inside the front panel of the appliance. Battery box receiver caution do not use a screwdriver or other metallic object to remove the batteries from the battery box! This could cause a short circuit to the receiver. Ignition wire connection (spade type con...

  • Page 47

    47 8. Disconnect the wire from the battery box. 9. Remove the cover of the battery box (1 screw). 10. Insert four aa alkaline batteries in the battery box, refi t the cover and secure with the screw. Note: do not put batteries in the receiver, only in the battery box. 11. Reconnect the battery box a...

  • Page 48

    48 remove front middle platform support accessing air shutter close open injector elbow bracket, burner side injector elbow air shutter setting air shutter install trim and barrier screen install the trim chosen by the customer for the fi replace. Install as well the barrier screen which is provided...

  • Page 49

    49 wiring diagram wall switch kit connector gv60 wiring diagram remote battery box 4 aa batteries qualified installer.

  • Page 50

    50 approved venting components approved direct vent suppliers for valor outdoor fireplace model 1500 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps horizontal st...

  • Page 51

    51 approved venting components venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm pipes 4” x 6 5/8” ( id x od ) 6” long galvanized 46dva-06 4dt-06 tc-4dl6 sv4l6 — — — 94610606 black ...

  • Page 52: Lor

    52 warranty 1. Two-year parts warranty two (2) years from the date of purchase, the company, at its option, will repair or exchange all parts and components that are found to have a erqd¿gh defect in material or workmanship under normal conditions of use. 2. Conditions and limitations the warranty r...

  • Page 53

    53 spare parts code description part number 1 heat shield 4003049 2 45 degrees fl anged elbow 0945m 3 elbow gasket 4002999 4 top stand-offs (2) 4002985 5 restrictor plate 4003017 6 take-off cover (2) 4003046 7 lh window latch assembly 4002770 8 rh window latch assembly 4002766 9 top panel support 40...

  • Page 54

    54 spare parts code description part number 68 small beige beach pebbles (2) 4003087 69 grade 1a vermiculite, bagged 4002940 70 decorative glass set 1500dgs 71 glacier ice fireglass, bagged (3) 4004521 72 fireglass tray 4003473by 73 middle platform brackets (2) 4003033 74 hot glass warning plate 400...

  • Page 55

    55 spare parts 1 2 3 4 7 9 10 11 8 52 50 49 51 12 13 14a, 14b 48 15 17 18 19-23 24-25 26 27a, 27b 28 29 30 31 32 33 34 36a, 36b 35 38 37 6 5 41 42 47 45 46 43 44 74 owner’s information.

  • Page 57

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 58

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.