Valor 4190 Owner's Manual

Manual is about: inset live fuel effect gas fires with ultimate fireslide or fusion front

Summary of 4190

  • Page 1

    600a920/02 model 4190 (for natural gas) model 4191 (for propane gas) i n s e t l i v e f u e l e f f e c t g a s f i r e s with u l t i m a t e f i r e s l i d e or f u s i o n front o w n e r g u i d e this owner guide is intended to help you care for your valor gas fire. Please read carefully befo...

  • Page 2

    2 thank you for choosing valor. All valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service. Your owner guide aims to improve your understanding and appreciation of your valor gas fire by prov...

  • Page 3

    3 safety if you smell gas don’t smoke extinguish all naked flames don’t turn electrical switches on or off turn off the gas supply at the meter open doors and windows to get rid of the gas immediately call the gas emergency service - see your local telephone directory 1. As with any gas appliance, t...

  • Page 4

    4 gas consumption natural gas appliances (model 4190) have a maximum gas input at the high setting of 6.0kw (gross) and a minimum gas input at the low setting of 2.7 kw (gross). Propane gas appliances (model 4191) have a maximum gas input at the high setting of 6.1kw (gross) and a minimum gas input ...

  • Page 5

    5 operating the fire the flame sensing & flue blockage safety system. For your safety, this appliance is fitted with a flue blockage safety device which will shut down the appliance in the event of abnormal flue conditions. This device is not a substitute for an independently mounted carbon monoxide...

  • Page 6

    6 cleaning turn the fire off and allow it to cool before attempting any cleaning. Note that the fire will retain heat for some time after it has been turned off. If large pieces of debris are found anywhere in the fireplace, have the chimney inspected before further use. Metal parts clean the metal ...

  • Page 7

    7 3. Place the rear base coal in the burner compartment behind the front coal. Its rear face should touch the rear ceramic wall (see figure 6). 4. The ceramic side walls are marked at the rear bottom corners “l” (left side) & “r” (right side). Place the side walls against the sides of the fire box a...

  • Page 8

    8 maintenance battery replacement (see fig 11). This appliance requires 9v pp3 ever ready silver seal (or equivalent) battery. To replace the battery remove the bottom front cover casting. Fit the new battery firmly to the connections on the generator, the positive battery terminal (+) being to the ...

  • Page 9

    A) your post code. B) type of fire. C) model/name. D) serial number. E) the fault, problem or request. General advice about gas and your gas fire: valor adviceline 0345 626341. To report faults or arrange for your fire to be serviced: valor service 0121 386 6203. To order spares or for sales informa...

  • Page 10

    Safety first. Valor fires are ce approved and designed to meet the appropriate british standards and safety marks. Quality and excellence. At the heart of every valor fire. All valor fires are manufactured to the highest standards of quality and excellence and are manufactured under a bs en iso 9001...