Valor 520AN Installation & Operation Manual - page 7
7
Take the
ashlip/front feet
assembly and
observe the
attachment
arrangements
(see Figure 5) at
the rear of the
assembly, and
place on the
floor, in front of
the fireplace.
Take the left side panel
and remove the assembly
bolt using a 7/16th
wrench or socket.
Attach the side panel to
the ashlip assembly. It
may assist to slacken the
ashlip bracket retaining
bolt during this process.
Replace side bolt and
tighten both bolts. Take
the remaining side panel
and repeat the assembly
process. Lifting carefully,
place the entire Side
Panel/Ashlip assembly
onto the hearth.Check
the Side Panel/Ashlip
assembly is level and that there is not a discernible vertical gap
against the Fireplace, adjust the side panel leveling feet to
eliminate any such gap. Once leveling is complete adjust the
ashlip support legs so that they just touch the hearth panel
(Figure 6). Carefully lift the Side Panel/Ashlip assembly off the
hearth to allow preparation and connection of the heat engine.
4. PREPARATION
Turn the appliance on its side with the control valve facing
upwards.
Insert the control shaft into the guide tube (see figure 6A).
Turn the control shaft to align the Phillips head screw with the
flat on the valve shaft.
Slacken the Philips head screw and locate the control shaft boss
over the valve shaft.
Leave the Phillips head
screw slack until the
casting is fitted.
Stand the heater
upright.
Remove the window
unit assembly by
detaching the
knurled screws at the
sides near the top.
Lift the window unit
up to clear locations
at the bottom and
place carefully aside
(see fig. 7).
Carefully remove the
ceramic logs from
inside the firebox and
place to one side.
Fit the flue collar to
the back of the heater
using four thread
cutting screws
provided. (See fig. 8).
Fit the smoke
channel (for venting
check) to the back of
the heater using four
thread cutting screws
provided. (See fig. 8).
Fit the top rear wall
spacer provided by
attaching it to the 2
bolts visible on the
rear of the heater convection hood above the flue collar. (Lock
washer and nuts provided in pack). (See fig. 8).
If installing to #401CVK Concealed Vent Kit
When installing the Valor President to the #401 Concealed Vent
Kit, the vent collar does not penetrate sufficiently into the flue
adaptor box to ensure good extraction of the combustion
products. The collar extension assures good extraction.
If the Valor President is not being installed to the #401
Concealed vent kit don’t use the extension.
Fitting the extension (See figure 8A):
•
Make the extension into a coil small enough to fit inside the
vent collar.
•
Push the coiled extension right into the vent collar as far as it
will go.
•
Release the extension so that the coil expands against the
inner diameter of the collar.
•
Seal the joint between the collar and extension all round with
the sealing tape
.
Fig. 5 Ashlip & feet assembly
Fig.6 Assembled sides and ashlip
Fig. 7 Window removal
Fig. 8 Flue collar, smoke channel & wall
spacer installation
Fig. 6A
Fig. 8A Extension collar