Valor 530ICN Installation & Owner's Manual

Manual is about: DV Gas Fireplace Heater

Summary of 530ICN

  • Page 1

    4001754-18 p ortrait installation & owner’s manual dv gas fireplace heater 530iln/ilp (logs), 530icn/icp (coals), 530irn/irp (rocks) this manual contains instructions to install the en- gine only. A front trim kit is required to install the engine as it affects the framing cavity and posi- tion of t...

  • Page 2

    2 table of contents safety precautions ............................................3 safety and your fireplace .................................4 owner’’s information ..........................................5 remote control operation.................................9 options .........................

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, •• parts of your valor fireplace become extremely hot while in operation. •• the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ...

  • Page 5: Do Not Put

    5 owner’s information operating your fireplace for the first time when operating your new  replace for the  rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the  ames to be the full ...

  • Page 6

    6 cleaning important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white  lm on the ceramic glass of the viewing door. The composition of the deposit varies with location and time. It is believed to be ass...

  • Page 7

    7 owner’’s information thermocouple probe must be in flame correct fl ame appearance with logs with coals with rocks 7. If the hot glass warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated. 8. Reinstall the...

  • Page 8

    8 on off wall switch (optional) manual on/off switch thermostatic remote control lighting, operation and rating information the lighting, operation and rating information is located on a plate under the  rebox. To access the plate, remove any fret or access panel and grab the plate and slide it out...

  • Page 9

    9 remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment •• on the valve, turn man knob on the on, full counterclockwise position. •• place on/off switch (if equipped) in i (on position). S...

  • Page 10

    10 remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large  ame) or the (small  ame) buttons. •• press and hold (small  ame) button to decrease  ame height or to set the appliance at p...

  • Page 11

    11 remote control operation setting the on / off temperatures •• brie y press set button to scroll to temp (sun) mode. Hold the set button until the temp  ashes. •• press (large  ame) button to increase the daytime set temperature. •• press (small  ame) button to decrease daytime set temperature...

  • Page 12

    12 remote control operation setting program timers •• you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. •• the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . •• the icon indicates the beginning of the period (on) and the...

  • Page 13

    13 options automatic turn down automatic shut off low battery indication handset / receiver match remote handset: the battery icon will show when the battery needs to be replaced. Replace with one 9 v alkaline battery. Receiver: three short ‘‘beeps’’ will sound when the motor turns when the batterie...

  • Page 14

    14 lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow thes...

  • Page 15

    15 state of massachusetts carbon monoxide detector/vent terminal signage requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth...

  • Page 16

    16 commonwealth of massachusetts (d) manufacturer requirements - gas equipment venting system not provided. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the  ue gases, but identi es ““special venting systems””...

  • Page 17

    17 speci cations approvals and codes this appliance is certi ed to ansi z21.88a––2012/ csa 2.33a––2012 american national standard/csa standard for vented gas fireplace heaters for use in canada and usa. The appliance complies with csa p4.1-09, testing method for measuring annual fi replace effi ci...

  • Page 18

    18 dimensions, clearance and framing the dimensions, clearances and framing vary with each applications and with the front trim installed. Refer to the installation instructions of the front trim chosen for more information. Speci cations co-linear direct vent installations for free standing or rec...

  • Page 19

    19 •• the vent terminal must be located on an outside wall or through the roof. •• this direct vent appliance is designed to operate when an undisturbed air ow hits the outside vent terminal from any direction. •• the minimum clearances from this terminal that must be maintained when located on an ...

  • Page 20

    20 horizontal termination venting con gurations see venting accessories list on pages 40––41 for allowable components. Rear outlet—no vertical rise flat on the wall •• maximum 26”” horizontal pipe length; •• 817vak vent collar adapter required if using other than valor’’s 551dvk pipe with terminati...

  • Page 21

    21 horizontal termination venting con gurations rear outlet w/vertical rise —horizontal termination •• 817vak vent collar adapter required; •• maximum 2 x 90° elbows allowed (or equivalent: 2 x 45° elbows = 1 x 90° elbow); •• a terminal guard such as 845tg is required where the vent terminal is loc...

  • Page 22: & Vapor Barriers

    22 horizontal termination installations •• the 530 heater may be installed using components from a variety of manufacturers listed on pages 40––41. •• allowable vent con gurations and clearances for the 530 heater are listed in this manual and apply for all vent components listed on pages 40––41. F...

  • Page 23

    23 vertical termination venting con gurations see venting accessories list on pages 40––41 for allowable components. Top outlet through roof (co-axial pipe) see conversion to top outlet for solid direct vent co-axial piping in appliance preparation section for conversion to top outlet. •• 817vak ve...

  • Page 24

    24 vertical termination venting con gurations see venting accessories list on pages 40––41 for allowable components. Co-linear venting into existing solid-fuel burning fireplaces and chimneys co-linear adapter may be installed as top or rear outlet——see conversion to top outlet for solid direct ven...

  • Page 25

    25 ‘h’ horizontal overhang vertical wall termination cap storm collar roof flashing plumber’s tape fixed to wall strap wall strap ceiling firestop ceiling support offset elbows min. 18” overhang should not extend beyond vent if within 48” of termination cap min. 24” (unvented soffit) min. 36” (vente...

  • Page 26

    26 2 x 3” liners 530 engine co-linear vent installations 1. The size of the  replace cavity required to insert the 530 engine varies with the style of front trim chosen. Refer to the front trim installation manual for required dimensions. 2. Place the appliance ( tted with the co-linear adapter) n...

  • Page 27

    27 conversion to top outlet for solid direct vent co-axial piping if installing with rear vent outlet, go to next step. 1. Remove the top plate and seal by unscrewing 12 screws. Keep the seal, plate and screws for  tting to the back. 2. Remove the rear outer vent collar and seal by unscrewing 12 sc...

  • Page 28

    28 vent outlet preparation for co-axial installations using non-valor vent components if installing straight off the back venting with valor terminal kit 551dvk only, ignore this step: 1. Fit the adapter 817vak over the appliance vent collars pushing on  rmly. Align the adapter so that the seam on ...

  • Page 29

    29 attaching air restrictors—appliances with vertical vent rise only no restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage. Two restrictor sets, like the o...

  • Page 30

    30 gas supply installation •• it’’s preferable to rough-in the gas line at this point before proceeding with the  rebox installation. •• the appliance is supplied for supply gas connection at the control valve. Supply line connection to the control valve of the appliance is 3/8 inch npt (female). T...

  • Page 31

    31 ceramic walls installation (logs and coals only) the 530il and 530ic engines are provided with a set of reversible walls. One side shows the brick pattern and the reverse side shows a black vertical  uted pattern. Follow the instructions below to install the wall set on the chosen side. • for ce...

  • Page 32

    32 ceramic logs installation 1. Place the base log on the supports in the  rebox and against the support at the  rebox back. 2. Locate the rear upper log on the two ceramic pins at the rear of the base log. 3. Place the front log behind the metal strip at the front of the  rebox. 4. Locate the ri...

  • Page 33

    33 ceramic coals installation 1. Place the base coal on the supports in the  rebox and against the  rebox back. 2. Place the left front coal in position behind the metal lip at the front of the  rebox. The side projection on this coal should be near the middle front of the  rebox. 3. Place the r...

  • Page 34

    34 ceramic rocks installation the ceramic rock set is packed in three cartons. Unpack each piece carefully to avoid damages. You should have in hand the following items: carton 4001879 •• ceramic platform carton 4002055 •• left and right side reversible brick/ uted ceramic panels •• rear panel supp...

  • Page 35: Tfl

    35 ceramic rocks installation to get the optimal  ame effect, it is important to place the rocks in their appropriate position. Each rock is embossed underneath with letters and an arrow indicating the position of the rock. The arrows point to the front of the fi replace when the rock is installed....

  • Page 36

    36 window re tting and checking 1. Place the window centrally against the engine unit and resting on the support at bottom front of the engine. 2. Pull the clamping bars forward and rotate inwards to secure the top of the window. 3. Fit the two spring loaded bolts through the bottom of the window a...

  • Page 37

    37 operation check & aeration settings adjustment open open close close ng flashback shield (for lpg only) lpg air shutter slider open close lpg ng air shutter slider & cover operation check turn the  replace  ame up and down using the remote control to con rm that the full range of inputs is ach...

  • Page 38

    38 packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 remote control handset wall holder installation the remote control kit for this  replace comes complete with a wall-...

  • Page 39

    39 wiring diagram optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram qualified installer.

  • Page 40

    40 approved direct vent suppliers for valor models 530, 534, 535, 650, and mf28 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries termination caps horizontal co-axial kit, 26” long — — ...

  • Page 41

    41 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries pipes 4” x 6 5/8” ( id x od ) 6” long galvanized 46dva-06 4dt-06 tc-4dl6 sv4l6 — — — black 46dva-06b 4dt-06(b) tc-4dl6b sv4lb6 7” lo...

  • Page 42

    42 warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the ““company””) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in ...

  • Page 43

    43 replacement parts code description part no. 1 side wall support (2) 330a898 2 rear wall support 320b320 4 velcro strip 4000022 5 port cover 4000828ah 6 inner vent collar 340b174 7 inner vent collar seal 620b973 8 top vent collar seal 568399 9 top vent cover plate 330a902 10 wall bracket spacer (2...

  • Page 44

    44 1 2 4 5 6 7 8 9 10 11 12 13 14 19 20 21 22a 22b 23 24 25 26 27 28 29 30 31 33 32 34 35 36 38 39 40 41 42 44 43a, 43b 45 46 47 48 41a 41b ng lpg 16a 16b 15a 15b replacement parts 44a 49 owner’s information.

  • Page 45

    45 51 52 53 54 55 56 57 58 59 60 61 62 63 50 replacement parts 64 65 66 67 69 73 71 74 72 75 76 77 78 79 80 81 70 68 for 530irn/p only for 530iln/p and icn/p owner’s information.

  • Page 47

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a quali ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www....

  • Page 48

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.