Valor 739-72ILN/P Installation And Owner's Manual

Manual is about: Legend G3 series DV Gas Insert (Contemporary Black Front & Logs

Summary of 739-72ILN/P

  • Page 1

    Legend g3 4004616-07 ©2017, miles industries ltd. Dv gas insert 739-72iln/p (contemporary black front & logs) installation & owner’s manual — do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. — what to do if you smell gas ▪ do not try ...

  • Page 2

    Safety precautions ................................................. 3 safety and your fireplace ...................................... 4 owner’s information ............................................... 5 operating your fireplace for the first time ............... 5 annual inspection ...............

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi rebo...

  • Page 6

    Owner’s information 1. Inspect and operate the pressure relief mechanism to verify relief mechanisms are free from obstruction to operate—see cleaning your fireplace: to refi t the window section of this manual. 2. Clean glass window with a suitable fi replace glass cleaner. Abrasive cleaners must no...

  • Page 7: Warning

    Owner’s information cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit varies with location a...

  • Page 8: Warning

    Owner’s information 5. Apply fi rm hand pressure around the window frame to ensure the window is sealed tight against the fi rebox. 6. If the hot glass warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated. 7. ...

  • Page 9: Warning

    Owner’s information to replace the batteries in the remote control receiver: 1. The receiver is located to the left of the valve behind the front’s lower panel. It is retained to the fi rebox by a velcro tab. Unhook the lower panel and grab the receiver and pull it out from its location. 2. Slide and...

  • Page 10

    Remote control operation your fi replace remote control helps you get the comfort, convenience and aesthetics you want from your gas fi replace. The remote controls your fi replace in diff erent ways. Important: before you begin, please note that on this system, the settings of time, temperature and aut...

  • Page 11

    Remote control operation programming time and temperature you can set your fi replace to come on before you wake up and turn off after you leave and then, turn on again just before you come home and turn off after going to bed. You can leave it like this for the heating season. 1. Decide what temperatu...

  • Page 12

    Kits & accessories required kits* venting approved venting accessories as listed in this manual on page 29 and per local codes. Optional kits* see your dealer for your choice of outer surrounds and trims. Other accessories 755cfk—fan kit 759ebl—enamel liners 760cbl—ceramic black fluted liners 400151...

  • Page 13

    Lighting instructions for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow ...

  • Page 14

    X x ratings model iln ilp gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 26,000 24,000 input minimum (btu/h) 6,500 13,000 manifold pressure (in w.C.) 3.6 10.0 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w.C.) 10.0 14.0 main burner injector marking ...

  • Page 15: Warning

    Overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero clearance kit. 7...

  • Page 16

    28-5/8” (727 mm) 19-1/2” (495 mm) 12 - 14” (305 - 357 mm) varies with outer trim options 9-3/8 - 11-3/8” (238 - 289 mm) varies with outer trim options 20” (508 mm) gas inlet gas connection electrical inlet optional outer trim or surround sold separately x y dimensions cavity check that masonry step ...

  • Page 17: Warning

    A b do not put furniture or objects within 36” (914 mm) of the front of appliance sidewall clearances minimum distance from side of appliance (liner box) to combustible wall: 9” (229 mm). Mantel legs projecting forward less than 6” (152 mm) may be located within 5” (127 mm) of the side of the applia...

  • Page 18

    Terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed typical vent installation see the approved venting components list on page 29 of this manual. Vent location the vent terminal must be located through the roof. This direct vent appliance is designed to operate when an undi...

  • Page 19

    Installation planning existing fireplace preparation a few points must be considered before inserting the 739-72 into an existing fi replace cavity. Generally, no modifi cations are allowed to the existing fi replace that will compromise the integrity of the existing fi replace. Components that are bolt...

  • Page 20

    Unpack the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance. 3. Remove the window and set aside in a safe place to avoid damage—see next page. 4. Verify that you have all the components required for the installation, including...

  • Page 21

    Electrical outlet fan cavity installation remove window the window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2. Gently pull the bottom of the window outward and unhook it from ...

  • Page 22: Option 2B

    Connect venting important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process....

  • Page 23

    Supply pressure test tapping manifold pressure test tapping connect gas supply the gas supply inlet connection is a 3/8” npt female connector and is located on the left hand side of the control valve. Use only new black iron or steel pipes or copper tubing if acceptable—check local codes. Note that ...

  • Page 24

    Installation install ceramic logs unpack the ceramic logs very carefully to avoid damaging the fragile material. Install the logs as shown below. Please note that the position of the logs is critical to ensure proper performance of the appliance. 1. Place the rear log centering it side to side in th...

  • Page 25

    Installation refi t and check window 1. To refi t the window, place the window against the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. The top of the window frame is identifi ed. 2. While you hold it, push in and turn the two bottom spring-loaded bolts a...

  • Page 26

    Installation push-on connector connect remote control receiver 1. Connect the wiring harness to the receiver box, by pushing the wire connector on to the receiver circuit board. The plug will only go on one way so please ensure that the wires are pointing up and the slot in the board is in line with...

  • Page 27

    Packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 open open close close natural gas flashback shield (for propane gas only) air shutter slider (propane gas) open close pr...

  • Page 28

    Install front and barrier screen the 772 contemporary front is designed to be used on the valor legend g3 heater 739-72 along with an outer surround trim (supplied separately). The contemporary front fi ts within the outer surround trim and clips onto the standard mounting brackets supplied with the ...

  • Page 29

    Approved venting components approved direct vent suppliers for valor models 700, 739 3 , 780, 785 and rf24dv venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps v ert...

  • Page 30: Lor

    Warranty warr an ty pr og ram warr an ty pr og ram va lor co m fo r t va lor co m fo r t va lor co m fo r t 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial owner for the repair ...

  • Page 31

    Spare parts code description part number 1 exhaust slide assembly 4001133 2 exhaust slide gasket 4001662 3 fan closure plate 4001136 4 port cover 4001820 5 log support 4006177 6 top mounting bracket 4000136az 7 side mounting brackets (2) 4000135az 8 window assembly 4001378 9 hot glass warning plate ...

  • Page 32

    Spare parts natural gas propane gas 18 20 25 21 22 23 24 19 43 44 45 1 2 3 4 5 6 7 8 46 49 48 47 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 42 40a, 40b 14a natural gas propane gas 13a 41 50 51 52 53 54 55 49 47 32 owner’s information.

  • Page 33

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www.V...

  • Page 34

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.