    L egend g4 4004339-03 ©2014, miles industries ltd. Direct vent gas insert 780jn (ng) & 780jp (lpg) patent pending installation and owner’s manual this manual contains instructions to install the engine only. A front is also required to complete this installation. A barrier screen is pro- vided with ...

  • Page 2

    Designed and manufactured by / for miles industries ltd. 190–2255 dollarton highway, north vancouver, bc, canada v7h 3b1 tel. 604-984-3496 fax 604-984-0246 www.Valorfi replaces.Com © copyright miles industries ltd., 2014 the information contained in this installation manual is believed to be correct...

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 owner’s information operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the fu...

  • Page 6: Warning

    Owner’s information cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit varies widely from va...

  • Page 7

    Hot glass plate owner’s information 3. Apply light hand pressure against the window frame sides to bed-in the window seal. 4. If the hot glass warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated. 5. Reinsta...

  • Page 8: Warning

    Owner’s information replacing batteries low battery signal: see page 15. Before changing the batteries, disconnect the battery box from the receiver. The appliance uses four 1.5 v aa alkaline batteries for its battery box and one 9 v alkaline battery for its handset. Batteries should last one to two...

  • Page 9

    Wall switch (optional) remote control handset manual on/off switch off on owner’s information how to turn your fireplace off (including pilot) familiarize yourself with each of these methods before operating your fi replace. Handset and wall switch: press and hold the off button for a second. If the...

  • Page 10

    When the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position). Standby mode (pilot flame) • p...

  • Page 11

    Setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the appliance at pilot fl ame. • for fi ne ...

  • Page 12

    • - nighttime setback temperature mode (appliance must be in standby mode; pilot ignited) - the room temperature is measured and compared to the nighttime setback temperature. The fl ame height is then automati- cally adjusted to achieve the night- time setback temperature. • - timer mode (appliance...

  • Page 13

    Setting the “nighttime setback” tempera- ture default settings: (moon), “ -- ” (off) • press (large fl ame) button to increase nighttime setback temperature. • press (small fl ame) button to decrease nighttime setback temperature. • press off or simply wait to complete programming. • briefl y press ...

  • Page 14

    • briefl y press set button to scroll to timer (moon) while the time fl ashes. • press (large fl ame) button to set the hour. • press (small fl ame) button to set the minutes. Setting p2 on time • briefl y press set to scroll to timer mode (sun) while the time fl ashes. • follow the instructions giv...

  • Page 15

    Remote control operation options required kits* venting see approved venting accessories listed on page 39. Liner 786lslv2—ledgestone liner set 787eblv2—enamel black liner set 788fblv2—fluted black liner set 789vrlv2—valor red brick liner set fuel bed 781rsk—rock set 782lsk—log set front (all with b...

  • Page 16

    Lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow these i...

  • Page 17

    X x ratings model ng lpg gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 30,000 28,000 input minimum (btu/h) 6,500 14,500 manifold pressure (in w.C.) 4.0 10.5 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w.C.) 10.0 14.0 main burner injector marking 8...

  • Page 18: Warning

    Overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero clearance kit....

  • Page 19

    33” (838 mm) 24” (610 mm) 15” (381 mm) 15” (381 mm) 4” (102 mm) 3” (76 mm) 3” (76 mm) 3” (76 mm) 10” (254 mm) 23” (584 mm) gas line access gas line approx. 24“ (610 mm) of flex protruding from sheet metal box optional fan optional fan 6’ (1,8 m) fan power cord outlet 6’ (1.9 m) fan power cord trim (...

  • Page 20: Warning

    9” (229 mm) a b non-combustible hearth with optional fan: depth +3” (76 mm) do not put furniture or objects within 36” (914 mm) of the front of appliance sidewall clearances minimum distance from side of appliance (liner box) to combustible wall: 9” (229 mm). Mantel pro- jection a 1” (25 mm) 4” (101...

  • Page 21

    3” liners 3” min. Bend radius terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed existing fi replace and chimney typical vent installation see list of approved venting accessories on page 39 of this manual. Note: flexible co-linear vent pipes may only be installed into ex...

  • Page 22

    Installation planning installer—read this first 1. You need to know from the homeowner what accessories (surround, screen, fan/blower, etc.) will be installed with this fi replace; 2. Unpack the appliance. 3. Check that you have everything. 4. Clean cavity, chimney, ash dump, and clean-out. 5. Insta...

  • Page 23

    Unpack the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance and check against the pack content list provided in the documentation package. 3. Remove the window and set aside in a safe place to avoid damage—see next page. 4. Ve...

  • Page 24

    Installation install fan (if used) if the 795cfkv2 circulating fan kit (blower) is to be installed, we suggest that you do it now. The fan cavity is accessible from the back of the fi rebox to facilitate its installation. If the fan is retrofi tted after the installation of the appliance, the applia...

  • Page 25: Option 2B

    Connect venting important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process....

  • Page 26

    Connect gas supply the gas supply inlet connection is a 1/2” npt female. Gas shut-off valve supplied on the end of stainless steel fl exible connector. Flex connector is located on the left hand rear corner of the appliance. Use only new black iron or steel pipes or copper tubing if acceptable—check...

  • Page 27

    Front view, left side top view, left side flex connector redirected using one elbow. Flex connector redirected using two elbows. Common fi ttings required (not supplied) 3/8” elbow + short 3/8” nipple or 3/8” street elbow(s) (where al- lowed) 1. Remove fl ex connector. 2. Remove fl ared connector. 3...

  • Page 28

    Install liner panels the following guidelines apply for all brick liners. 1. Remove the rear log support (3 screws). 2. Remove the front brick support. 3. Inside the fi rebox, on the top of each side, release the screw of the side brick anchors (one per side) just enough to allow them to rotate. 4. ...

  • Page 29

    9. Reinstall the front brick support. 10. Reinstall the rear log support (3 screws). Its rear edge rests on the rear brick support ledge. 11. With logs only: install the front bricks in front of the burner. 12. With logs only: slide the cast iron grate in the slots in front of the burner. 1. Center ...

  • Page 30

    2. Place the black glass piece on top of the burner and move it forward to rest in the grooved recess of the grate and center it. The glass should not hang over the space between the burner and the rear log. 3. Identify the left log and place it over the peg on top of the rear log as shown. The lowe...

  • Page 31

    6. Identify the top right log. It is the longest of the two remaining logs. Place its wider end on the front right log’s peg and rest its narrow end in the notch on the rear log. 7. Place the top left log’s wider end on the peg of the front left log and rest its narrow end in the notch on the rear l...

  • Page 32

    1. Install the platform frame into the fi rebox over top of the burner. The metal tabs at the bottom of the frame slide into the slots in front of the burner. 2. Insert the ceramic platform, textured side up, into the frame. 3. Insert the ceramic rock base in the platform behind the burner. Ensure t...

  • Page 33

    14 11 9 7 4. Each rock is embossed underneath with a number and an arrow indicating its position. The arrow points to the front of the fi replace when the rock is installed. See the image at the beginning of this section to help you identify and position the rocks. 5. Identify rocks number 1, 2, 3, ...

  • Page 34

    Refi t and check window 1. To refi t the window, place it in its bottom railing and rotate its top against the fi rebox. 2. While you hold it, pull the side levers back into the window brackets on each side. 3. Apply light hand pressure against the window frame sides to bed-in the window seal. 4. If...

  • Page 35

    Synchronize remote control the receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Remove the cover of the battery box (1 screw). 2. Insert alkaline batteries in the battery box and handset. 3. Refi t the cover and secure with the screw. 4. ...

  • Page 36

    Check operation turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs is achieved—see the remote control operation instructions on pages 10-15. Adjust aeration (if necessary) light the fi re and allow the unit to warm up for 10–15 minutes to evalua...

  • Page 37

    Install front, trim and barrier screen install the front or trim chosen by the customer for their fi replace. Install as well the barrier screen which is provided with the front or trim. Show the customer how to access the controls when the front or trim are installed and how to remove them. Follow ...

  • Page 38

    Red yellow wiring diagram remote battery box optional 795cfkv2 fan control module 4 aa batteries gv60 max wiring diagram optional wall switch kit 1265wsk connector 38 qualified installer.

  • Page 39

    Approved venting components approved direct vent suppliers for valor models 700, 739 3 , 780, 785 and rf24dv venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps v ert...

  • Page 40: Lor

    Warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in mater...

  • Page 41

    Spare parts code description part number 1 exhaust slide assembly 4002287 2 exhaust slide gasket 4000176 3 restrictor enclosure 4002330 4 metal strip 4002329 5 restrictor assembly 4002333 6 coil spring 4002605 7 rod support 4002331 8 cover 4002289 9 access panel gasket 4002664 10 access plate 400251...

  • Page 42

    Spare parts code description part number 76 rock no. 18 40026461 77 lh twig 4001827 78 rh twig 4001828 79 ceramic platform—sand 4002439 80 platform support assembly 4002663 81 liner panels—complete set a ledgestone 786lslv2 b enamel black 787eblv2 c ceramic black 788fblv2 d valor red brick 789vrlv2 ...

  • Page 43

    Spare parts 1 2 3 - 7 8 9 10 11 12 13 14 40 41 42 43 44 45 46 47 48 49 50 51 52 54 53 55 56 - 57 79 80 81 82 83 84 85 86 87 15 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 41a ng lpg 16 - 23a 24 25 26 27 - 32 33 34a, 34b 35 38 39 36 37 25a 88 43 owner’s information.

  • Page 45

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 46

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.