    600a743/01 o w n e r g u i d e this owner guide is intended to help you care for your valor gas fire. Please read carefully before using your gas fire and keep for future reference. This owner guide gives sufficient details to enable your gas fire to be operated and maintained. Important. Please kee...

  • Page 2

    2 thank you for choosing valor. All valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service. Your owner guide aims to improve your understanding and appreciation of your valor gas fire by prov...

  • Page 3

    3 safety • soft wall coverings (e.G. Embossed vinyls etc.) are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this is mind when having a heating appliance installed and when redecorating. • as with any gas fire, this applianc...

  • Page 4

    4 thank you for choosing this valor gas fire. It has been designed to give years of trouble-free service. To maintain its optimum performance, advantage should be taken of the regular servicing and inspection facilities available for gas appliances. Annual servicing is recommended. These instruction...

  • Page 5

    5 turn the control knob gradually to your desired setting. Both burners should gradually increase in output until at max position the main burner is at its greatest heat output and the decorative flames are at their full magnitude. 2.5 to turn off 2.5.1 to turn the main and decorative flames off but...

  • Page 6

    6 3.3.2 place the front right coal (embossed 'b' underneath) in position. The flat bottom front face of the coal should rest on the metal ledge immediately behind the bottom front of the firebox opening. Slide the coal to the right side. See figure 6. 3.3.3 place the front left coal (embossed 'c' un...

  • Page 7

    7 3.3.5 place the rear right coal (embossed 'd' underneath) in position as shown in figure 8. 3.3.6 place the rear left coal (embossed 'e' underneath) shown in figure 9. 3.3.7 replace the window unit ensuring that the seal around the frame is not damaged or misplaced. Secure with the 12 wing nuts ti...

  • Page 8

    8 servicing & maintenance • in order to achieve and maintain high levels of personal safety and performance efficiency it is essential that the flue terminal outside the building is kept clear of any form of obstruction. • we recommend that all gas appliances and their flues, are checked annually by...

  • Page 9

    9 safety first . Valor fires are ce approved and designed to meet the appropriate british standards and safety marks. Quality and excellence. At the heart of every valor fire. All valor fires are manufactured to the highest standards of quality and excellence and are manufactured under a bs en iso 9...