    For 600b336/03 v a l o r c o s y f l a m e ( m o d e l b r 6 2 3 ) & v a l o r s e c r e t ( m o d e l b r 4 2 7 ) & v a l o r g r a m p i a n ( m o d e l b r 4 2 7 ) i n s e t l i v e f u e l e f f e c t g a s f i r e s ( g . C . 3 2 - 0 3 2 - 1 5 ) i n s t a l l e r g u i d e please keep in a safe...

  • Page 2

    2 this installer guide gives sufficient details to enable the appliance to be installed and maintained. If further information is required, our valor advice line will be pleased to help. Please telephone 0345 626341 (local call rates apply) p l e a s e l e a v e t h i s i n s t a l l e r g u i d e w...

  • Page 3

    3 contents installation notes .......................................................................................................................4 technical specification ...............................................................................................................5 pack content...

  • Page 4

    4 installation notes in your own interest and for safety, in the united kingdom, it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the gas safety (installation & use) regulations and amendments. Failure to install the appliance correct...

  • Page 5

    5 an extractor fan may only be used in the same room as this appliance, or in any area from which ventilation for the appliance is taken, if it does not affect the safe performance of the appliance. Note the spillage test requirements detailed further on in this manual. If the fan is likely to affec...

  • Page 6

    6 general installation requirements this appliance is not suitable for installation in a room or internal space containing a bath or shower or where steam is regularly present or in a private garage. This appliance is suitable for the following: - 1. A masonry chimney with a minimum diameter of 175m...

  • Page 7

    7 fire surround: this appliance may be installed with a surround with a minimum approved temperature rating of 150 degrees. The fire surround must be sealed to the wall. Hearth requirements: the appliance must be mounted on a non-combustible hearth in accordance with figure 4. The hearth material mu...

  • Page 8

    8 cable retention cables and eyebolts are supplied for the retention of the appliance. Ensure that the internal fireplace components are sufficiently sound to take the eyebolts and wall plugs. These should be fitted in accordance with figure 6, using the wall plugs and a no.10 drill. Use only the fi...

  • Page 9

    9 that the pilot orifice is clear and that the thermocouple connections are sound. Replace the pilot unit if necessary (see servicing section of this manual). When the pilot is alight and stable, partially depress the knob and turn to “low”. The pilot should then light the main burner at its low set...

  • Page 10

    10 place the rear base coal in the burner compartment behind the front coal. It should rest on the ledge at the back of the burner compartment and its rear face should touch the rear ceramic wall (see figure 12 & 13). Install the 9 loose coals as follows. The smooth surfaces of the coals should be a...

  • Page 11

    11 full operating checks recheck control settings now that all the ceramic fuel effects are in position, the control operation must be fully rechecked. Make sure that the isolating valve at the inlet elbow is open. Depress the control knob and turn anti-clockwise partially towards the “pilot/ign” po...

  • Page 12

    12 final review model 623 - fit the top finials to the side pillars of the front casting. Place the front casting in position between the sides of the front surround. Place the bottom front cover casting below the front casting. Hand these instructions and the user’s instructions to the customer. Ad...

  • Page 13

    13 servicing & parts replacememt always turn off the gas supply before commencing any servicing. (the inlet elbow for this appliance incorporates an isolating valve). This product uses fuel effect pieces, burner compartment walls and gaskets containing refractory ceramic fibres (rcf), which are man-...

  • Page 14

    14 to remove the gas tap/f.S.D • remove the burner unit. • disconnect the electrode lead from tab underneath the electrode. • undo the thermocouple nut at the gas tap • disconnect the inlet pipe at the tap end • disconnect the pilot pipe at the tap end. • disconnect the main burner pipe at the tap e...

  • Page 15

    15 short list of spares key description no. Off part no. A injector bray cat 18 size 360 for natural gas appliances 1 541069 injector bray cat 18 size 170 for propane appliances 571709 b gas tap & spark generator 1 569429 c spark generator 1 521069 d control knob 1 545979 e pilot unit for natural ga...

  • Page 16

    16 a) your post code. B) type of fire. C) model/name. D) serial number. E) the fault, problem or request. General advice about gas and your gas fire: valor adviceline 0345 626341. To report faults or arrange for your fire to be serviced: valor service 0121 386 6203. To order spares or for sales info...

  • Page 17

    17 safety first . Valor fires are ce approved and designed to meet the appropriate british standards and safety marks. Quality and excellence. At the heart of every valor fire. All valor fires are manufactured to the highest standards of quality and excellence and are manufactured under a bs en iso ...