  • Page 1

    R a d i a n t / c o n v e c t o r g a s f i r e m o d e l 4 2 6 ( g c 3 2 8 1 1 4 0 ) installation & servicing instructions installer: please leave these instructions with the owner we trust that these instructions give sufficient details to enable this appliance to be installed and maintained satis...

  • Page 2

    2 list of contents page overall dimensions …..................................................................................................................................................................... 2 appliance data ............................................................................

  • Page 3

    3 1. Appliance data 1.1 this product uses a fuel effect piece containing refractory ceramic fibres (rcf), which are man-made vitreous silicate fibres. Excessive exposure to this material may cause temporary irritation to eyes, skin and respiratory tract. Consequently, it makes sense to take care whe...

  • Page 4

    4 2.3 in the united kingdom, as supplied, the appliance can be installed in the following situations. 2.3.1 conventional fireplace and hearth the appliance can be installed to a fireplace complete with surround and hearth the fireplace opening must be within the following dimensions: width: max. 432...

  • Page 5

    5 25mm with a minimum clearance of 50mm between its open end and the nearest obstruction. There must also be a minimum clearance of 165mm between the back of the closure plate and the back of the catchment space. The catchment space below the flue spigot must extend at least 250mm downwards measured...

  • Page 6

    6 3. Unpacking & pre-installation preparation 3.1. Carton contents the carton contains the following:- 1. Fire assembly. 1. Ceramic fuel effect (in packaging inside firebox). 1. Closure plate. 1. Flue spigot. 1. Pair of feet (for floor mounting the appliance).* 1. Pair of feet shrouds (for floor mou...

  • Page 7

    7 3.3.4. Remove the control bezel by unscrewing two screws (see fig.5). 3.3.5. Detach the outer case by removing the screws at the case sides (see fig.5). 3.3.6. Pull the bottom of the case forwards while springing the bottom corners outwards to clear the fixing brackets. Lift the case upwards and f...

  • Page 8

    8 3.3.9.2 fit the feet to the underside of the appliance feet mounting brackets (see figure 9). 3.3.10 fit the flue spigot to the back of the fire using four screws provided. 3.3.11 if the fire is fitted to a recessed fireplace, an extension flue spigot up to a maximum total length of 125mm may be u...

  • Page 9

    4. Appliance installation 4.1 installing to a hearth 4.1.1. The levelling screw lock nuts should be accessible below the shrouds. If necessary, loosen the knurled screws securing the shrouds, raise the shrouds and resecure them. To prevent scratching the hearth, fit the two plastic caps (supplied in...

  • Page 10

    10 5. Full operating checks 5.1 check control settings 5.1.1. To help in checking the control positions while the outer case is detached, place the control bezel over the gas tap spindle and against the tap bracket. Temporarily secure to the tap bracket with one of the screws. 5.1.2. Fit the control...

  • Page 11

    11 the installation is satisfactory if all the smoke is drawn into rectangular opening in the closure plate. If any smoke is escapes from the top or side of the appliance, leave the appliance alight at the maximum setting for a further ten minutes and then repeat the test. If all the smoke is still ...

  • Page 12

    12 8. Servicing & parts replacement • always turn off the gas supply and make sure that the appliance is cool before commencing any servicing. • always test for gas soundness and spillage after servicing the appliance. • it is recommended that, at least once a year, the appliance is disconnected and...

  • Page 13

    13 8.5. To remove the burner, pipes and pilot 8.5.1. Remove the outer case as section 8.2. 8.5.2. Remove the coal as section 8.3. 8.5.3. Detach the gas tap and disconnect the thermocouple from the tap as section 8.4. 8.5.4. Remove the screw and shakeproof washer fixing the burner at the right side 8...

  • Page 14

    14 replacement parts - short list key no. Description no. Off makers part no. A b c d e f g h j k injector - upper - bray 99 size 150b injector - bray 99 size 240 gas tap copreci & spark generator spark generator pilot unit inlet elbow window unit control knob coal dust cage 1 1 1 1 1 1 1 1 1 1 5221...

  • Page 15

    15 valor heating erdington, birmingham b24 9qp because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. © valor ltd.