Valor HORIZON 534JN Installation & Owner's Manual

Manual is about: DV Gas Fireplace Heater

Summary of HORIZON 534JN

  • Page 1

    4005126-03 © 2016, miles industries ltd. All rights reserved. H orizon installation & owner’s manual dv gas fireplace heater 534jn (ng) & 534jp (lpg) this manual contains instructions to install the en- gine only. A front trim kit is required to install the engine as it affects the framing cavity an...

  • Page 2

    22 table of contents designed and manufactured by / for miles industries ltd. 190–2255 dollarton highway, north vancouver, bc, canada v7h 3b1 tel. 604-984-3496 fax 604-984-0246 www.Valorfi replaces.Com © copyright miles industries ltd., 2016 the information contained in this installation manual is b...

  • Page 3: Safety Precautions

    33 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be...

  • Page 4: Safety And Your Fireplace

    44 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can c...

  • Page 5: Do Not Put

    55 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi...

  • Page 6

    66 cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit varies with location and time. It is b...

  • Page 7

    77 correct flame picture—rocks owner’s information 5. Apply fi rm hand pressure around the window frame to ensure the window is sealed tight against the fi rebox. 6. If the hot glass warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glas...

  • Page 8

    88 on off wall switch (optional) manual on/off switch thermostatic remote control thermostatic remote control wall switch (optional) to access the card, remove any fret or access panel and grab the card and slide it out to read it. There is important information on both sides of the card. Servicing ...

  • Page 9

    99 on off manual on-off switch owner’s information if the fl ames are on, they go down and you hear the valve motor wind down. You hear a clunk and a beep indicating that the valve has received the signal from the remote control. Manual on/off switch: press the o button. As well, familiarize yoursel...

  • Page 10

    10 10 remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position)....

  • Page 11

    11 11 remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the applianc...

  • Page 12

    12 12 remote control operation setting the on / off temperatures • briefl y press set button to scroll to temp (sun) mode. Hold the set button until the temp fl ashes. • press (large fl ame) button to increase the daytime set temperature. • press (small fl ame) button to decrease daytime set tempera...

  • Page 13

    13 13 remote control operation setting program timers • you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. • the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . • the icon indicates the beginning of the period (on) and the...

  • Page 14

    14 14 remote control operation automatic turn down automatic shut off low battery indication handset / receiver match remote handset: the battery icon will show when the battery needs to be replaced. Replace with one 9 v alkaline battery. Receiver: frequent ‘beeps’ for 3 seconds when the motor turns...

  • Page 15

    15 15 options required kits* fuel beds (choose one) 534lsk log set 534rsk rock set liners (choose one) 618rgl refl ective glass liners 620fbl fluted black liners 621vrl valor red brick liners 622lsl ledgestone liners fronts (choose one) barrier screen 601 contemporary steel front 4003550 602 traditi...

  • Page 16

    16 16 lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow t...

  • Page 17

    17 17 state of massachusetts carbon monoxide detector/vent terminal signage requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwea...

  • Page 18

    18 18 commonwealth of massachusetts (d) manufacturer requirements - gas equipment venting system not provided. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi es “special venting syste...

  • Page 19

    19 19 specifi cations approvals & codes these appliances are certifi ed by ansi z21.88-2014/csa 2.33-2014 american national standard / csa standard for vented gas fireplace heaters for use in canada and usa. These appliances are for installation directly venting through an outside wall or through th...

  • Page 20

    20 20 overview fire on/off wall switch (optional) mantel—see dimensions section for mantel clearances hearth (if used) may be combustible. Install the bottom of the heater fl ush with the top of fi nished hearth for most applications. See instructions provided with optional front trims. Front with s...

  • Page 21

    21 21 mantel depth “a” 1” (25 mm) 2” (51 mm) 3” (76 mm) 4”–5” (102–127 mm) 6” (152 mm) 7” (178 mm) 8”–12” max. (203–305 mm) max. Mantel clearance “b” 7” (178 mm) 8” (203 mm) 9” (229 mm) 10” (254 mm) 11” (279 mm) 12” (305 mm) 14” (356 mm) dimensions mantel 36” (914 mm) min. See table a b 23-1/8” (587...

  • Page 22

    22 22 • a non-combustible hearth is not necessary in front of this appliance. • note that the unit is installed at the framing stage and fi xed to framing using support angles. See page 30. Wall fi nish is then installed over the support angles up to the black frame on the unit. Note: if using a 613...

  • Page 23

    23 23 location venting vent material this unit is approved for installation using 4 x 6-5/8 inches approved co-axial direct vent pipes and acces- sories listed on pages 43–44 of this guide. Follow the installation instructions supplied with the individual venting accessories. This unit may also be c...

  • Page 24

    24 24 horizontal termination 2-piece wall thimble pipe length pipe length pipe length 817vak 817vak pipe length 90˚ elbow ceiling firestop attic firestop attic insulation shield flashing storm collar vertical termination typical co-axial venting components co-axial venting qualified installer.

  • Page 25

    25 25 important installer notice – weather sealing & vapor barriers it is the installer’s responsibility to ensure that vent installations through exterior walls are caulked and weatherproofed in such a manner as to: • prevent rain water from entering the wall from the weather side by adequately cau...

  • Page 26

    26 26 co-axial venting horizontal vent termination location • the vent terminal must be located on an outside wall or through the roof. • this direct vent appliance is designed to operate when an undisturbed airfl ow hits the outside vent terminal from any direction. • the minimum clearances from th...

  • Page 27

    27 27 min. 6” rise for top outlet 817vak adapter: required for top or rear outlet. Max. 24” before elbow min. 12” rise 45° elbow directly on flue collar is allowed with min. 6” pipe between elbows 1” min. All around vertical pipe 3” min. Above top of horizontal pipe 1” min. Around bottom & sides of ...

  • Page 28

    28 28 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 2 4 6 8 10 12 14 16 rear outlet top outlet 1 1 2 4 6 8 10 12 14 16 1 3 5 3 5 0.5 1 2 3 1 2 3 0.5 1 2 3 1 2 3 how to read the venting chart the chart below applies to co-axial roof or...

  • Page 29

    29 29 ‘h’ horizontal overhang vertical wall termination cap storm collar roof flashing plumber’s tape fixed to wall strap wall strap ceiling firestop ceiling support offset elbows min. 18” overhang should not extend beyond vent if within 48” of termination cap min. 24” (unvented soffit) min. 36” (ve...

  • Page 30

    30 30 co-linear vent installations • the chimney and fi replace opening sizes are shown in dimensions and location sections of this manual. • place the appliance (fi tted with the co-linear adapter) near the fi replace opening but allow space for manipulating the chimney liners on to the appliance. ...

  • Page 31

    31 31 installation remove window 1. Turn the top two spring-loaded window bolts through 90 degrees to release the window from the fi rebox. 2. Remove the bottom two spring-loaded window bolts. 3. Carefully lift the window away. Keep the window and bolts in a safe place. Convert to rear vent outlet (...

  • Page 32

    32 32 install top heat shield & stand-offs 1. If installing appliance with top vent outlet, remove the plate covering the vent hole in the top heat shield by unscrewing four screws. If installing with rear vent outlet, the plate must remain to cover the hole. 2. Remove the screws at the top rear cor...

  • Page 33

    33 33 adjustable piece air restrictor assembly install air restrictors no restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage. Two restrictor sets, like the...

  • Page 34

    34 34 install appliance into framing 1. Place the heater in position in the framing. 2. Secure the side support angles to the side studding through two holes each side with the woodscrews supplied. The top support angle should abut the wall fi nish but is not fi xed to the framing. 3. Check the wall...

  • Page 35

    35 35 connect gas supply • the gas supply pipe should enter the appliance case through the opening at the left side. The supply pipe should be connected to the appliance gas inlet pipe situated at the left side of the control valve. Supply line connection to the inlet pipe is 3/8 inch npt ( female)....

  • Page 36

    36 36 install liner panels all liner panels can be installed as indicated below except the 618rgl—refl ective glass liners—see instructions packed with the liners. Unpack the liners carefully to avoid scratching or damaging them. 1. Place the rear panel against the back of the fi rebox on the ledge ...

  • Page 37

    37 37 install 534lsk ceramic logs unpack the ceramic logs very carefully to avoid damaging their fragile material. Install the logs as shown below. Please note that the position of the logs is critical to insure the good performance of the appliance. 1. Place the rear log on the sheet metal support ...

  • Page 38

    38 38 6. Place the lower end of the center right log onto the pin on the front right log. Rest the narrow end in the notch into the rear log. 7. Pour some ceramic loose coals on each side of the logs to hide the sheet metal work. Do not put any coal into the pilot area. Installation notch in rear lo...

  • Page 39

    39 39 to p bottom 1. Install the front support platform in the fi rebox carefully sliding it down between the burner and the front bottom edge for the fi rebox while avoiding scraping the side ceramic panels. 2. Place the rock ceramic base on the log support behind the burner. The front bottom of th...

  • Page 40

    40 40 4. The underside of each ceramic rock is identi- fi ed by a number and a specifi c protruding positioning triangle. Install the six rocks from left to right starting with rock no. 1. Note: the ceramic base may need to be slightly adjusted side-to-side to allow stones to fi t within the platfor...

  • Page 41

    41 41 refi t and check window 1. Refi t the window with the bottom two bolts. The bolts should be screwed in securely. 2. Refi t the top two bolts securing by turning them through 90 degrees. 3. Pull the top of the window forward and release to check that it opens slightly and returns confi rming th...

  • Page 42

    42 42 check operation turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs is achieved—see the remote control operation instructions on pages 10–14. Adjust aeration (if needed) light the fi re and allow the unit to warm up for 10–15 minutes to eva...

  • Page 43

    43 43 install front, trim and barrier screen install the front or trim chosen by the customer for their fi replace. Install as well the barrier screen which is provided with the front or trim. Show the customer how to access the controls when the front or trim are installed and how to remove them. F...

  • Page 44

    44 44 wiring diagram optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram qualified installer.

  • Page 45

    45 45 approved venting components approved direct vent suppliers for valor models 530 6 , 534, 650 and mf28 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps horizo...

  • Page 46

    46 46 approved venting components venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm pipes 4” x 6 5/8” ( id x od ) 6” long galvanized 46dva-06 4dt-06 tc-4dl6 sv4l6 — — — 94610606 bla...

  • Page 47: Lor

    47 47 warranty warr an ty pr og ram warr an ty pr og ram va lor co m fo r t va lor co m fo r t va lor co m fo r t 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial owner for the r...

  • Page 48

    48 48 replacement parts key description part no. 1 top stand-offs (2) 3000192 2 top heat shield panel 350a008 3 top frame support angle bracket 3000181 4 outer vent collar 330a888 5 blanking plate 330a964 6 side frame fi xing brackets (2) 3000255 7 side stand-offs brackets (2) 320b423 8 convection h...

  • Page 49

    49 49 key description part no. D ledgestone 4002114 59 log set complete 534lsk 60 rear log 4003795 61 left top log 4003796 62 right top log 4003797 63 right center log 4003798 64 left front log 4003800 65 right front log 4003801 66 loose coals pieces 4001843 67 rock set complete 534rsk 68 rock no. 1...

  • Page 50

    50 50 replacement parts 77 78 79 80 ng lpg 19 21 26 27 28 29 30 22 23 24 25 20 16a 16b 40 41 5 15a 15b 39 4 38 3 13 18 2 12 17 56 57 58 59 60 61 64 62 65 63 66 1 6 6 7 7 9 8 10 11 11a 32 31 37 36 33 34 35 50 48 55 54 53 52 51 45a, 45b 46 46a 47 68 69 70 71 72 73 74 67 75 76 owner’s information.

  • Page 51

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 52

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.