Figure 5. Front Coal Location
Figure 4. Ceramic Base Location
FUEL BED REFITTING
If the fuel bed components
are dislodged or removed,
they must be refitted as
follows:
Only the fuel bed parts
supplied with this appliance
or authorised replacements
must be used. Never add
extra coals above the
number stated in these
instructions.
1.
Place the ceramic base
coal in the burner
compartment. The bottom
rear face of the coal should
rest against the angled ledge
at the back of the burner
tray. The coal does not rest on top of the
angled ledge.The bottom front edges of the
coal base should locate against the left and
right hand side brackets. (See figure 4).
(Installer - Note that the small round holes
in the burner plaques that will be covered by
the base coal are not gas burner ports. They
are simply a consequence of the plaque
manufacturing process).
2.
Place the left-hand ceramic front coal in
position in front of the base coal (See figure
5).
3.
Place the right hand ceramic front coal in
position in front of the base coal. This
should overlap the left-hand coal. Push the
two sides together to minimise the gap. (See
figure 5).
4.
There will be a gap between the rear of
the front coals and the front of the base coal.
(See figure 5).