Valor LEGEND G3 739JN Installation & Owner's Manual

Summary of LEGEND G3 739JN

  • Page 1

    4005137-03 ©2016, miles industries ltd. Dv gas insert 739jn (ng) & 739jp (lpg) installation & owner’s manual this manual contains instructions to install the engine only. A front is also required to complete this installation. A barrier screen is pro- vided with the front. Refer to the manual sup- p...

  • Page 2

    Safety precautions ................................................. 3 safety and your fireplace ...................................... 4 owner’s information ............................................... 5 operating your fireplace for the first time ............... 5 cleaning your fireplace .........

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi ...

  • Page 6: Warning

    Bottom of window (wider frame) owner’s information cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of th...

  • Page 7

    Owner’s information 5. Apply fi rm hand pressure around the window frame to ensure the window is sealed tight against the fi rebox. 6. If the hot glass warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated. 7...

  • Page 8: Warning

    Owner’s information the appliance area must always be kept clear and free from combustible materials, gasoline and other fl ammable vapors and liquids. Inspect the vent terminal outdoors regularly to make sure that snow, trees, bushes, leaves, or other objects do not obstruct it. Examine the vent sy...

  • Page 9

    On off manual on/off switch wall switch (optional) remote control handset owner’s information how to turn your fireplace off (including pilot) familiarize yourself with each of these methods before operating your fi replace. Handset and wall switch: press and hold the off button for a second. Manual...

  • Page 10

    Remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position). Stand...

  • Page 11

    Remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the appliance at p...

  • Page 12

    Remote control operation setting the on / off temperatures • briefl y press set button to scroll to temp (sun) mode. Hold the set button until the temp fl ashes. • press (large fl ame) button to increase the daytime set temperature. • press (small fl ame) button to decrease daytime set temperature. ...

  • Page 13

    Setting program timers • you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. • the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . • the icon indicates the beginning of the period (on) and the icon indicates the end of the ...

  • Page 14

    Remote control operation automatic turn down automatic shut off low battery indication handset / receiver match remote handset: the battery icon will show when the battery needs to be replaced. Replace with one 9 v alkaline battery. Receiver: frequent ‘beeps’ for 3 seconds when the valve motor turns...

  • Page 15

    Options required kits* fuel beds (choose one) 739lsk log set 739rsk rock set 739dwk driftwood kit liners (choose one) 739rgl refl ective glass liners 739fbl fluted black liners 739vrl valor red brick liners inner fronts (choose one) barrier screen 741 contemporary steel front 4003360 742 traditional...

  • Page 16

    Lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow these i...

  • Page 17

    X x ratings model ng lpg gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 26,000 24,000 input minimum (btu/h) 6,500 13,000 manifold pressure (in w.C.) 3.6 10.0 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w.C.) 10.0 14.0 main burner injector marking 8...

  • Page 18: Warning

    Overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero clearance kit....

  • Page 19

    28-5/8” (727 mm) 19-1/2” (495 mm) 12 - 14” (305 - 357 mm) varies with outer trim options 9-3/8 - 11-3/8” (238 - 289 mm) varies with outer trim options 20” (508 mm) gas inlet gas connection electrical inlet optional outer trim or surround sold separately x y dimensions cavity check that masonry step ...

  • Page 20: Warning

    A b do not put furniture or objects within 36” (914 mm) of the front of appliance 9” (229 mm) sidewall clearances minimum distance from side of appliance (liner box) to combustible wall: 9” (229 mm). Mantel legs projecting forward less than 6” (152 mm) may be located within 5” (127 mm) of the side o...

  • Page 21

    Terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed typical vent installation see the approved venting components list on page 39 of this manual. Vent location the vent terminal must be located through the roof. This direct vent appliance is designed to operate when an und...

  • Page 22

    Installation planning existing fireplace preparation a few points must be considered before inserting the 739 into an existing fi replace cavity. Generally, no modifi cations are allowed to the existing fi replace that will compromise the integrity of the existing fi replace. Components that are bol...

  • Page 23

    Unpack the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance and check against the pack content list provided in the documentation package. 3. Remove the window and set aside in a safe place to avoid damage—see next page. 4. Ve...

  • Page 24

    Electrical outlet fan cavity installation remove window the window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2. Gently pull the bottom of the window outward and unhook it from ...

  • Page 25: Option 2B

    Connect venting important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process....

  • Page 26

    Supply pressure test tapping manifold pressure test tapping connect gas supply the gas supply inlet connection is a 3/8” npt female connector and is located on the left hand side of the control valve. Use only new black iron or steel pipes or copper tubing if acceptable—check local codes. Note that ...

  • Page 27

    Rotate anchor up and insert panel position of panel in relation to burner plate edge of burner plate side panels should be parallel to edge of burner plate change fuel bed support (if necessary) the appliance is supplied with the log support already installed. If installing the log set 739lsk, ignor...

  • Page 28

    Port cover installed installation 4. Rotate the anchor up and out of the way and slide the right hand side panel against the fi rebox side. The panel should be parallel to the edge of the burner plate. Rotate the anchor back down to hold the panel. 5. Tighten the side brick anchors on each side of t...

  • Page 29

    Install 739lsk ceramic logs unpack the ceramic logs very carefully to avoid damaging the fragile material. Install the logs as shown below. Please note that the position of the logs is critical to ensure proper performance of the appliance. 1. Place the rear log on the sheet metal support centering ...

  • Page 30

    6. Place the lower end of the center right log onto the pin on the front right log. Rest the narrow end in the notch into the rear log. 7. Pour some ceramic loose coals on each side of the logs to hide the sheet metal work. Do not put any coal into the pilot area. Notch in rear log pin in front righ...

  • Page 31

    To p bottom install 739rsk ceramic rocks the use of the 739rsk ceramic rock set requires a change from the factory-installed log support to the rock support supplied with this kit. See section change fuel bed support on page 27 for instructions on how to change the fuel bed support before proceeding...

  • Page 32

    4. The underside of each ceramic rock is identifi ed by a number and a specifi c protruding positioning triangle. Install the six rocks from left to right starting with rock no. 1. 5. Place the glass panel in its cavity formed by the front support and the ceramic platform. Rock identifi cation trian...

  • Page 33

    Installation install 739dwk driftwood kit the log support is factory-installed in a specifi c position which can be adjusted if necessary. Moving the support forward will allow more impigement/glow/fl ame height on the left side of the fi re; moving the support backward will do the opposite. Unpack ...

  • Page 34

    Installation 4. Identify the right side cross log, the longest, and place it across the rear log. The narrow end of the log rests in a notch of the rear log. The wide end of the log lays fl at on the platform, fl ush with the edge as indicated. 5. Identify the left side cross log which has one pin a...

  • Page 35

    Bottom of window (wider frame) refi t and check window 1. To refi t the window, place the window against the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. 2. While you hold it, push in and turn the two bottom spring-loaded bolts a quarter turn to engag...

  • Page 36

    Open open close close ng flashback shield (for lpg only) lpg air shutter slider open close lpg ng air shutter slider & cover synchronize remote control the receiver and the handset of the remote control sys- tem must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in th...

  • Page 37

    Packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 install handset wall holder the remote control kit for this fi replace comes complete with a wall-mounted holder. This h...

  • Page 38

    Optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram wiring diagram qualified installer 38.

  • Page 39

    Approved venting components approved direct vent suppliers for valor models 700, 739 3 , 780, 785 and rf24dv venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps v ert...

  • Page 40: Lor

    Warranty warr an ty pr og ram warr an ty pr og ram va lor co m fo r t va lor co m fo r t va lor co m fo r t 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial owner for the repair ...

  • Page 41

    Code description part number 1 exhaust slide assembly 4001133 2 exhaust slide gasket 4001662 3 fan closure plate 4001136 4 port cover 4001820 5 log support 4004353 6 side bricks anchors (2) 4001283 7 top mounting bracket 4000136az 8 side mounting brackets (2) 4000135az 9 window assembly 4001378 10 b...

  • Page 42

    Spare parts code description part number 70 left panel fluted black 4001812 valor red brick 4001809 refl ective glass 4005015 filler panel 4005018 71 right panel fluted black 4001813 valor red brick 4001810 refl ective glass 4005016 72 log set complete 739lsk 73 rear log 4003787 74 lh top log 400378...

  • Page 43

    Spare parts ng lpg 18 20 25 21 22 23 24 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a, 45b 14a ng lpg 13a 47 48 49 50 51 52 53 49a 72 73 74 75 76 77 78 79 44 55 56 57 58 59 60 61 54 62 63 70 71 69 68 67 64 65 66 43 owner’s information.

  • Page 45

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 46

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.