Valor LEGEND G4 785XN Installation And Owner's Manual

Manual is about: Direct Vent Gas Insert

Summary of LEGEND G4 785XN

  • Page 1

    L egend g4 4004802-02 ©2016, miles industries ltd. Direct vent gas insert 785xn (ng) & 785xp (lpg) patent pending installation and owner’s manual this manual contains instructions to install the engine only. A front is also required to complete this installation. A barrier screen is pro- vided with ...

  • Page 2

    Safety precautions ................................................. 3 safety and your fireplace ...................................... 4 owner’s information ............................................... 5 operating your fireplace for the first time ............... 5 cleaning your fireplace .........

  • Page 3: Safety Precautions

    3 safety precautions !! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 owner’s information operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the fu...

  • Page 6: Warning

    Warning ! Owner’s information cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit varies wide...

  • Page 7

    Owner’s information to refi t the window: 1. Place the window in its bottom railing and push its top against the fi rebox. Ensure to remove any particles in the railing before installing the window. 2. While you hold it, hook the side levers into the window tabs. 3. Pull out the top of the window an...

  • Page 8: Warning

    Owner’s information 4. Replace the batteries with 4 aa alkaline batteries. 5. Replace the cover and screw in place. 6. Reconnect the battery box. 7. Put the battery box back in its position. 8. Reinstall the left access door. Locating lighting, operation and rating information card the lighting, ope...

  • Page 9

    How to turn your fireplace off (including pilot) familiarize yourself with each of these methods before operating your fi replace. Handset and wall switch: press and hold the off button for a second. If the fl ames are on, they go down and you hear the valve motor wind down. You hear a clunk and a b...

  • Page 10

    Remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position). Stand...

  • Page 11

    Remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the appliance at p...

  • Page 12

    Remote control operation • - nighttime setback temperature mode (appliance must be in standby mode; pilot ignited) - the room temperature is measured and compared to the nighttime setback temperature. The fl ame height is then automati- cally adjusted to achieve the night- time setback temperature. ...

  • Page 13

    Remote control operation setting the “nighttime setback” tempera- ture default settings: (moon), “ -- ” (off) • press (large fl ame) button to increase nighttime setback temperature. • press (small fl ame) button to decrease nighttime setback temperature. • press off or simply wait to complete progr...

  • Page 14

    • briefl y press set button to scroll to timer (moon) while the time fl ashes. • press (large fl ame) button to set the hour. • press (small fl ame) button to set the minutes. Setting p2 on time • briefl y press set to scroll to timer mode (sun) while the time fl ashes. • follow the instructions giv...

  • Page 15

    Remote control operation low battery indication handset / receiver match remote handset: the battery icon will show when the battery needs to be replaced. Replace with one 9 v alkaline battery. Receiver: frequent ‘beeps’ for 3 seconds when the valve motor turns indicate the batteries need to be repl...

  • Page 16

    Lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow these i...

  • Page 17

    X x ratings model ng lpg gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 28,000 26,000 input minimum (btu/h) 14,000 15,000 manifold pressure (in w.C.) 3.5 9.0 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w.C.) 10.0 14.0 main burner injector marking 8...

  • Page 18: Warning

    Overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero clearance kit....

  • Page 19

    33” (838 mm) 24” (610 mm) 15” (381 mm) 15” (381 mm) 4” (102 mm) 3” (76 mm) 3” (76 mm) 3” (76 mm) 10” (254 mm) 23” (584 mm) gas line access gas line approx. 24“ (610 mm) of flex protruding from sheet metal box optional fan optional fan 6’ (1,8 m) fan power cord outlet 6’ (1.9 m) fan power cord trim (...

  • Page 20: Warning

    9” (229 mm) a b non-combustible hearth with optional fan: depth +3” (76 mm) do not put furniture or objects within 36” (914 mm) of the front of appliance sidewall clearances minimum distance from side of appliance (liner box) to combustible wall: 9” (229 mm). Mantel legs projecting forward less than...

  • Page 21

    3” liners 3” min. Bend radius terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed existing fi replace and chimney typical vent installation see list of approved venting accessories on page 36 of this manual. Note: flexible co-linear vent pipes may only be installed into ex...

  • Page 22

    Installer—read this first 1. You need to know from the homeowner what accessories (surround, screen, fan/blower, etc.) will be installed with this fi replace; 2. Unpack the appliance. 3. Check that you have everything. 4. Clean cavity, chimney, ash dump, and clean-out. 5. Install venting pipes. 6. A...

  • Page 23

    Unpack the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance and check against the pack content list provided in the documentation package. 3. Remove the window and set aside in a safe place to avoid damage—see next page. 4. Ve...

  • Page 24

    Installation install fan (if used) if the 795cfkv2 circulating fan kit (blower) is to be installed, we suggest that you do it now. The fan cavity is accessible from the back of the fi rebox to facilitate its installation. If the fan is retrofi tted after the installation of the appliance, the applia...

  • Page 25: Option 2B

    Connect venting important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process....

  • Page 26

    Installation connect gas supply the gas supply inlet connection is a 1/2” npt female. Gas shut-off valve supplied on the end of stainless steel fl exible connector. Flex connector is located on the left hand rear corner of the appliance. Use only new black iron or steel pipes or copper tubing if acc...

  • Page 27

    Front view, left side top view, left side flex connector redirected using one elbow. Flex connector redirected using two elbows. Common fi ttings required (not supplied) 3/8” elbow + short 3/8” nipple or 3/8” street elbow(s) (where al- lowed) 1. Remove fl ex connector. 2. Remove fl ared connector. 3...

  • Page 28

    Install liner panels the following guidelines apply to all panels except 787rgl refl ective glass liners for which separate instructions are provided with the kit. You do not need to remove the burner to install the panels unless you wish to install the 785rgp refl ective glass panel— see instructio...

  • Page 29

    Install driftwood kit 1101dwk material required • long beach driftwood kit, which contains: • 3 logs • 5 pebbles • 1 x 1.5 lb bag of 3/4” grey/black shale • gloves, if desired installation logs carefully unpack the kit. Each log has pegs to help you locate them on the ceramic burner platform. Instal...

  • Page 30

    Installation 4. Carefully spread shale in the cavity of the ceramic burner. You can also add some shale on the edge outside of the burner plate cavity. Note: ensure the area within the pilot shield is clear of shale pieces. Pebbles place the pebbles on the platform as shown below. Warning choking ha...

  • Page 31

    Installation install decorative glass murano 785xdgm material required • decorative glass murano kit, which contains: • 1 glass platform • 1 glass piece for pilot cover • 2 platform retainers • 1 pilot cover • 1 bag of clear 1/2” fi reglass • gloves (recommended to manipulate glass) installation car...

  • Page 32

    Installation install decorative glass set 785xdgs material required • decorative glass set, which contains: • 1 metal tray • 1 pilot cover • 3 bags of clear 1/2” fi reglass • gloves (recommended to manipulate glass) installation carefully unpack the kit. Wear gloves to handle the fi reglass. 1. Inst...

  • Page 33

    Installation refi t and check window 1. Place the window in its bottom railing and push its top against the fi rebox. Ensure to remove any particles in the railing before installing the window. 2. While you hold it, hook the side levers into the window tabs. 3. Pull out the top of the window and rel...

  • Page 34

    Synchronize remote control the receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Remove the cover of the battery box (1 screw). 2. Insert alkaline batteries in the battery box and handset. 3. Refi t the cover and secure with the screw. 4. ...

  • Page 35

    Installation air shutter close open check operation turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs is achieved—see the remote control operation instructions on pages 8–14. Adjust aeration (if needed) light the fi re and allow the unit to war...

  • Page 36

    Door hinge tabs should face inwards install side shrouds the side shrouds are required to install the front on the appliance. They are supplied with the engine. Fit them to the appliance outer case as indicated (2 screws/side). See instructions supplied with the front trim for installation of trim. ...

  • Page 37

    Wiring diagram remote battery box optional fan 795cfkv2 control module optional wall switch kit 1265wsk red yellow 4 aa batteries gv60 wiring diagram connector 37 qualified installer.

  • Page 38

    Approved venting components approved direct vent suppliers for valor models 700, 739 3 , 780, 785 and rf24dv venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps v ert...

  • Page 39: Lor

    Warranty warr an ty pr og ram warr an ty pr og ram va lor co m fo r t va lor co m fo r t va lor co m fo r t 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial owner for the repair ...

  • Page 40

    Spare parts code description part number 1 exhaust slide assembly 4002287 2 exhaust slide gasket 4000176 3 restrictor enclosure 4002330 4 metal strip 4002329 5 restrictor assembly 4002707 6 coil spring 4002605 7 rod support 4002331 8 valve access cover 4002289 9 side brick anchors (2) 4001283 10 lh ...

  • Page 41

    Spare parts code description part number 70 liner panels—complete set a ledgestone 786lslv2 b refl ective glass 787rgl c ceramic fl uted black 788fblv2 d valor red brick 789vrlv2 71 top panel a ledgestone 4002368 b ceramic black 4002374 c ceramic black 4002374 d valor red brick 4002385 72 rear panel...

  • Page 42

    Spare parts 68 43 44 45 46 47 48 49 50 70 71 72 73 74 1 2 3–7 8 9 10 12 14 15 13 11 16 23 25 26 17 18 19 19 21 22 20 32 – 38a 42 40 41 27a, 27b 29 9 39 51 52 53 54 55 55 56 57 58 59 60 65 66 67 61 62 63 64 63 42 owner’s information.

  • Page 43

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 44

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.