  • Page 1

    M adrona this manual contains instructions to install the engine only. A stove casing is required to install the engine. A barrier screen is provided with the stove casing. Refer to the manual sup- plied with the stove casing for installation. — do not store or use gasoline or other fl ammable vapor...

  • Page 2

    22 table of contents the information contained in this installation manual is believed to be correct at the time of printing. Miles industries ltd. Reserves the right to change or modify any information or specifi ca- tions without notice. Miles industries ltd. Grants no warranty, implied or stated,...

  • Page 3: Safety Precautions

    33 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be...

  • Page 4: Safety And Your Fireplace

    44 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can c...

  • Page 5: Do Not Put

    55 operating your stove for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi reb...

  • Page 6

    66 owner’s information cleaning your stove cleaning the window important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit va...

  • Page 7

    77 owner’s information to refi t the window: 1. Place it on its frame and hold it in place while pushing and turning its fastening studs 90 degrees. Then, apply light hand pressure against the window frame sides to bed-in the window seal. 2. If the hot glass warning plate has been removed from the f...

  • Page 8

    88 owner’s information the appliance area must always be kept clear and free from combustible materials, gasoline and other fl ammable vapors and liquids. Inspect the vent terminal outdoors regularly to make sure that snow, trees, bushes, leaves, or other objects do not obstruct it. Examine the vent...

  • Page 9

    99 thermostatic remote control wall switch (optional) owner’s information how to turn your stove off (including pilot) familiarize yourself with each of these methods before operating your stove. Handset and wall switch: press and hold the off button for a second (either on the handset or the wall s...

  • Page 10

    10 10 remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position)....

  • Page 11

    11 11 remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the applianc...

  • Page 12

    12 12 remote control operation setting the on / off temperatures • briefl y press set button to scroll to temp (sun) mode. Hold the set button until the temp fl ashes. • press (large fl ame) button to increase the daytime set temperature. • press (small fl ame) button to decrease daytime set tempera...

  • Page 13

    13 13 remote control operation setting program timers • you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. • the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . • the icon indicates the beginning of the period (on) and the...

  • Page 14

    14 14 remote control operation options required kits* stove casing (choose one) mfcs01—traditional madrona stove black with barrier screen 4003311 mfcs02—traditional madrona stove majolica brown with barrier screen 4003311 mfcs04—contemporary madrona stove with barrier screen 4003433 venting see ven...

  • Page 15

    15 15 lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow t...

  • Page 16

    16 16 state of massachusetts carbon monoxide detector/vent terminal signage requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwea...

  • Page 17

    17 17 requirements shall be satisfi ed by the manufacturer: 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be product approved by the board, and the instructions for that ...

  • Page 18

    18 18 specifi cations approval & codes this appliance is certifi ed to ansi z21.88-2014/ csa 2.33-2014 american national standard / csa standard for vented gas fireplace heaters for use in canada and usa, and to cga 2.17-91 high altitude standard in canada . This appliance is for direct vent install...

  • Page 19

    B a mantel 23” (584 mm) 7-1/2” (191 mm) 25-1/8” (638 mm) 27-1/2” (699 mm) 14” (356 mm) 17-7/8” (454 mm) Ø 6-5/8” venting supplied with top vent; field convertible to rear vent centre of vent 28-1/2 ” (724 mm) x gas inlet position 3/8” fem. Npt x 2” (52 mm) minimum gas line connection point 3/8” npt ...

  • Page 20

    20 20 dimensions & clearances contemporary cast stove mfcs04 x gas line connection point 32-1/16 ” (814 mm) 28-1/4” (718 mm) hinged control access door 28-7/8 ” (733 mm) x b a gas line access point 10” (254 mm) mantel 26-3/4” (680 mm) 15-3/16” (386 mm) 17-1/8” (435 mm) Ø 6-5/8” venting centre of ven...

  • Page 21: Por Barriers

    21 21 venting top / rear outlet this unit is shipped with a top outlet collar which is fi eld-convertible to rear outlet—see page 29 for details. Vent material this unit is approved for installation using 4 by 6-5/8 inches co-axial direct vent pipe and accessories—see list of approved venting pipes ...

  • Page 22

    22 22 snorkel required (min. 14” high) with horizontal run through the wall (no rise) venting through wall (without vertical rise) typical venting components see list of approved venting pipes and accessories on pages 36–37. Through wall (with vertical rise) through roof maximum pipe length: 24” (st...

  • Page 23

    5 x 90º elbows maximum restrictor 75 no restrict ors example 1 no installation no installa- tion v3 restrictor 50 2 4 6 8 10 12 14 16 18 20 23 23 venting allowable vent confi gurations example 1 v value = v1 (6’) + v2 (6’) + v3 (2’)= 14’ h value = h1 (3’) + h2 (3’) = 6’ 75% restrictor required verti...

  • Page 24

    24 24 venting restrictors some installations require restrictors. For improved fl ame picture and performance, this unit is supplied with two different sets of vent restrictors. The level of restriction required depends on the vertical rise in the venting system and, to a lesser degree, the horizont...

  • Page 25

    25 25 venting key vent terminal locations - minimum distances minimum clearance inches cm a clearance above grade, verandah, porch, deck or balcony 12 30 b clearance to window or door that may be opened 12 30 c clearance to permanently closed window (recommended to prevent condensation on window) 12...

  • Page 26

    26 26 installation planning fan (blower) allow for and install electrical wiring if there will be a fan (blower) to install. Ask the homeowner if you are not sure. Venting confi guration this unit is supplied with a top outlet and is fi eld convertible to a rear outlet. Plan routing of vent taking r...

  • Page 27

    27 27 installation x 4 remove window it is easier the remove the window and all the items packed inside of the fi rebox to make the engine lighter for installation. 1. Release the spring bolts at top and bottom of the window by pushing and turning 1/4 turn. 2. Lift the window and set it aside in a s...

  • Page 28

    28 28 installation fasten thermal switch to underside of burner module using 2 existing screws install fan (if used) if the circulating fan kit (blower) is to be installed, we suggest that you do it now. 1. Take the fan out of its package. 2. Remove the mounting plate from the fan and discard it. 3....

  • Page 29

    29 29 installation convert vent outlet (if necessary) if the appliance is to be vented from the top, it is ready for vent installation once the engine is on the casting base. If the appliance is to be vented from the rear, it must be converted. Follow these simple steps: 1. Remove the following part...

  • Page 30

    30 30 installation connect gas supply • the gas supply inlet connection is a 3/8 inch npt female connector. For detailed location of this connector see the drawing on page 18. If a circulating fan or isolating valve is to be installed, adjust the routing of the gas line to suit. • use only new black...

  • Page 31

    31 31 installation install ceramic logs unpack the ceramic logs very carefully to avoid damaging their fragile material. Install the logs as shown below. Please note that the position of the logs is critical to insure the good performance of the appliance. 1. Place the rear log on the sheet metal su...

  • Page 32

    32 32 x 4 refi t and check window to refi t the window: 1. Place it on the fi rebox frame and hold it in place while pushing and turning its fastening studs 90 degrees. 2. Then, apply light hand pressure against the window frame sides to bed-in the window seal. 3. If the hot glass warning plate has ...

  • Page 33

    33 33 installation synchronize remote control the receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner mo...

  • Page 34

    34 34 install front and barrier screen when installing the front of the stove make sure you install as well the barrier screen provided with the cast stove body. Show the customer how to remove the barrier screen and how to access the controls. Follow the instructions provided with the stove cast bo...

  • Page 35

    35 35 wiring diagram optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram qualified installer.

  • Page 36

    36 36 approved venting components approved direct vent suppliers for valor models 530 6 , 534, 650 and mf28 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm termination caps horizo...

  • Page 37

    37 37 approved venting components venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm pipes 4” x 6 5/8” ( id x od ) 6” long galvanized 46dva-06 4dt-06 tc-4dl6 sv4l6 — — — 94610606 bla...

  • Page 38: Lor

    38 38 warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in...

  • Page 39

    39 39 description part no. Description part no. 1 log set complete 4003804 32 hooked olive for pilot injec- tor 720a196 2 rear log 4003803 33 olive nut—pilot pipe to pilot assembly 420k385 3 left top log 4003796 34 electrode 720a543 4 right top log 4003797 35 electrode retaining nut 720a200 5 right ...

  • Page 40

    40 40 spare parts 8 9 10 11 50 75 12 13 14 16 17 20 21 66 18 22 65 ng lpg 23 24 27 25b 25a 28 37 29 31 36 32 33 34 35 38 39 40 42 41 43 44 45 46 47 48 52 53 54 49 56a, 56b 64 63 62 62a 58 57 59 60 30 26a 26b 50 15 67 1 2 3 4 5 6 7 19 owner’s information.

  • Page 41

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 42

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.