    Use, care, and installation guide model number: serial number: plateau vpl-e30as vpl-e36as summit vsu-e30as vsu-e36as crescent vcr-e30ag vcr-e36ag aug12.0401.

  • Page 3: Able of Contents

    1 safety notice ................................................................. 2-3 list of materials ....................................................... 4 installation ducting calculation sheet ....................................... 5 mounting height & clearance ................................

  • Page 4: Important Safety Notice

    Important safety notice read and save these instructions 2 warning to reduce the risk of fire or electric shock, do not use this fan with any solid-state control device. Warning to reduce the risk of fire electric shock, or injury to persons, observe the following: a. Use this unit only in the manne...

  • Page 5: Important Safety Notice

    Important safety notice 3 warning to reduce the risk of fire, use only metal ductwork. Caution to reduce risk of fi re and to properly exhaust air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Operation always leave safety grilles and fi lters...

  • Page 6: List of Materials

    List of materials 4 (3) wire nuts (3) m4 x 1-1/2” (2) m4 x 1” (4) 3/16” x 8 (vcr only) (4) m3.5 x 8 parts not supplied - ducting, conduit and all installation tools - cable connector (if required by local codes) - extension duct cover accessory - recirculating kit accessory hardware package contents...

  • Page 7: Installation –

    5 duct pieces total equivalent number length x used = 3- 1/ 4” x 10” rect., straight 1 ft. X ( ) = ft. 8” round, straight 1 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 elbow 15 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 45 0 elbow 9 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 flat elbow 24 ft. X ( ) = ft. 3- ...

  • Page 8: Installation –

    Installation – mounting height & clearance 6 ducting a minimum of 6” round duct must be used to maintain maximum air fl ow effi ciency. Always use rigid type metal ducts only. Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total duct work (page 5). Always,...

  • Page 9: Installation –

    7 warning fire hazard never exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal scr...

  • Page 10: Installation –

    8 installation – vsu hood specifi cations 2# 2 2 9 # 24 27 # 4 8 27 # 3: 26 27 # 9 4 5 # 7 8 9 # 23# 2: 4 5 # 52/4± 46 8 9 # - standard duct cover min. Ducted 27 1/2 ” min. Recirc. 32” max. Ducted 42 1/2 ” v1c-00su extension min. Ducted 46 1/2 ” min. Recirc. 50 1/2 ” max. Ducted 80”.

  • Page 11: Installation –

    9 installation – vpl hood specifi cation 4 8 9 # 7ȹ 21 4 9 # 46 41ȹ- 8 27 # 2 4 27 # 21 6 9 # 33 2!ȹ 27 6 6 27 # 29 8 27 # standard duct cover min. Ducted 27” min. Recirc. 31” max. Ducted 48” v1c-00pl extension min. Ducted 43 1/2 ” min. Recirc. 47 1/2 ” max. Ducted 81”.

  • Page 12: Installation –

    10 installation – vcr hood specifi cation 34 26 27 # 21 4 9 # 46 41ȹ- 4 27 # 4 8 9 # 21 6 9 # 2: 4 5 # 7ȹ standard duct cover min. Ducted 23” min. Recirc. 27” max. Ducted 42” v1c-00cr extension min. Ducted 41 1/2 ” min. Recirc. 45 1/2 ” max. Ducted 80” 26 8 27 #.

  • Page 13: Installation –

    11 1. Measure from range top to hood bottom and mark line a. (26” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line b. (12” from line a) 4. Mark mounting spread from c/l on line b. From center line to left mount mark (3-1/2”). From center line to right mount mark (...

  • Page 14: Installation –

    12 1. Measure from range top to hood bottom and mark line a. (26” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line b. (16-7/16” from line a) 4. Mark mounting spread from c/l. (8-7/8”) 5. Fasten (2) m4 x 1-1/2” screws into studs on line b but do not tighten all the...

  • Page 15: Installation –

    13 1. Measure from range top to hood bottom and mark line a. (26” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line b. (15-3/8” from line a) 4. Mark mounting spread from c/l. (8-7/8”) 5. Fasten (2) m4 x 1-1/2” screws into studs on line b but do not tighten all the ...

  • Page 16: Installation –

    14 (blower housing) ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional char...

  • Page 17: Features & Controls -

    15 1 3 3 features & controls - mechanical controls, vsu.

  • Page 18: Features & Controls -

    16 blower speed selection press to cycle through blowers speeds i, ii and iii blower on/off 1 lights bright/dim/off 3 3 lights bright/dim/off blower speed selection 2 delay off timer 4 blower on/off press to turn blower on and off. If lights are on they will also switch off when this button is press...

  • Page 19: Maintenance –

    17 surface maintenance: clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive st...

  • Page 20: Maintenance –

    18 pg uif replacing light bulbs caution: light bulb becomes extremely hot when turned on. Do not touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: bulb does ...

  • Page 21: Roubleshooting

    19 t roubleshooting troubleshooting procedures for vsu, vpl and vcr issue cause what to do after installation, the unit doesn’t work. 1. The power source is not turned on. 1. Make sure the circuit breaker and the unit’s power is on. 2. The power line and the cable locking connector is not connecting...

  • Page 22: List of Materials

    List of materials 20 description part# replacement parts light bulb gu-10 50w (each) z0b-0020 optional accessories recirculating kit vrc-00su (for vsu) vrc-00pl (for vpl) vrc-00cr (for vcr) replacement charcoal filter (each) v0f-c002 extension duct cover v1c-00su (for vsu) v1c-00pl (for vpl) v1c-00c...

  • Page 23: Limited Warranty

    1-888-750-1698 staple your receipt here to obtain service under warranty or for any service related questions, please call: venting services (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of range hoods (the “products”) that s...