  • Page 1

    Unvented (vent-free) natural gas log heater warning: this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to air for combustion and ventilation section on page 4 of this manua...

  • Page 2: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 2 104342 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch...

  • Page 3: Owner’S Manual

    Owner’s manual 3 104342 product identification figure 1 - product identification control knob back log base assembly piezo ignitor burner crossover log front log flame-max ® standard oak logs flame-max ® golden oak logs flame-max ® birch logs control knob piezo ignitor one piece log set one piece lo...

  • Page 4: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 4 104342 providing adequate ventilation the following are excerpts from national fuel gas code. Nfpa 54/ans z223.1, sec- tion 5.3, air for combustion and ventilation. All spaces in homes fall into one of the three following ventilation classificat...

  • Page 5: Owner’S Manual

    Owner’s manual 5 104342 determining fresh-air flow for heater location determining if you have a confined or unconfined space use this work sheet to determine if you have a confined or unconfined space. Space: includes the room in which you will install heater plus any adjoining rooms with doorless ...

  • Page 6: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 6 104342 air for combustion and ventilation continued figure 3 - ventilation air from outdoors figure 2 - ventilation air from inside building outlet air ventilated attic outlet air inlet air inlet air ventilated crawl space to crawl space to atti...

  • Page 7: Owner’S Manual

    Owner’s manual 7 104342 42" 16" notice: manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to installing damper clamp accessory ...

  • Page 8: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 8 104342 minimum noncombustible material clearances if not using mantel note: if using a mantel, proceed to if using mantel. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening....

  • Page 9: Owner’S Manual

    Owner’s manual 9 104342 installation continued figure 6 - minimum mantel clearances without using hood minimum non- combustible material minimum non- combustible material height distances to underside of mantel top of fireplace opening underside of mantel shelf mantel shelf 12" 8" (a) 18" 8" 20" 14"...

  • Page 10: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 10 104342 area of various standard round flues diameter (ins.) area (sq. Ins.) 5" 20 sq. Inches 6" 29 sq. Inches 7" 39 sq. Inches 8" 51 sq. Inches installing heater base assembly warning: you must secure this heater to fireplace floor. If not, hea...

  • Page 11: Owner’S Manual

    Owner’s manual 11 104342 installation continued figure 11 - attaching flexible gas hose to heater gas regulator figure 12 - attaching base assembly to fireplace floor masonry screw bracket with screw holes standard oak log chassis golden oak and birch model chassis masonry screw bracket with screw h...

  • Page 12: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 12 104342 tee joint pipe nipple cap 3" minimum sediment trap gas regulator from gas meter (5" w.C.** to 10.5" w.C. Pressure) a.G.A. Design-certified manual shutoff valve with 1/8" npt tap* approved flexible gas hose (if allowed by local codes) fig...

  • Page 13: Owner’S Manual

    Owner’s manual 13 104342 test pressures equal to or less than 1/2 psig 1. Close manual shutoff valve (see fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff val...

  • Page 14: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 14 104342 for golden oak or birch models it is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in figure 19. Make sure midd...

  • Page 15: Owner’S Manual

    Owner’s manual 15 104342 pilot off lo hi lighting instructions operating heater for your safety read before lighting warning: if you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot wh...

  • Page 16: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 16 104342 lo hi off pilot to turn off gas to appliance shutting off heater 1. Press in and turn control knob clock- wise clockwise to the high position. 2. Turn the control knob clockwise clockwise to the pilot position. 3. Press in control knob a...

  • Page 17: Owner’S Manual

    Owner’s manual 17 104342 inspecting burners check pilot flame pattern and burner flame patterns often. Pilot flame pattern figure 25 shows a correct pilot flame pat- tern. Figure 26 shows an incorrect pilot flame pattern. ( note : appearance of pilot assembly may vary by model.) the incor- figure 25...

  • Page 18: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 18 104342 troubleshooting warning: turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. Caution: never use a wire, needle, or similar object to clean ods/pilot. This can da...

  • Page 19: Owner’S Manual

    Owner’s manual 19 104342 observed problem burner does not light after ods/pilot is lit delayed ignition burner burner backfiring during combustion slight smoke or odor during initial operation heater produces a whistling noise when burner is lit moisture/condensation noticed on windows dark residue ...

  • Page 20: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 20 104342 troubleshooting continued warning: if you smell gas • shut off gas supply. • do not try to light any appliance. • do not touch any electrical switch; do not use any phone in your building. • immediately call your gas supplier from a neig...

  • Page 21: Owner’S Manual

    Owner’s manual 21 104342 optional positioning of thermostat sensing bulb for masonry and factory-built metal fireplace if your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensi...

  • Page 22: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 22 104342 specifications vintage oak vintage oak golden oak and birch 18" variable 24" variable 18" variable manually manually manually controlled controlled controlled btu (variable) 16,000/27,000 16,000/31,500 16,000/30,000 type gas natural gas ...

  • Page 23: Owner’S Manual

    Owner’s manual 23 104342 note: use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts under warranty contact authorized dealers of this product. If they can’t supply original replacement part(s), call desa international’s technical serv...

  • Page 24: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 24 104342 illustrated parts breakdown flame-max™ vintage oak log models vys18n and vys24n 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20 18 20-1 20-2 23 20-1 20-2 ods pilot.

  • Page 25: Owner’S Manual

    Owner’s manual 25 104342 parts list vys18n vys24n this list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under replacement parts on page 23 of this manual. Key part number for no. Vys18n vys24n description qty. 1 102968-01 102968-02 back log (#1...

  • Page 26: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 26 104342 illustrated parts breakdown flame-max™ golden oak and birch log models vyd18n, vybd18n, vyd24n, vybd24n, vyd30n, vybd30n, and vyd36n 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19 17 1a 1b 1a* * note: the golden oak log (10...

  • Page 27: Owner’S Manual

    Owner’s manual 27 104342 parts list vyd18n, vybd18n vyd24n, vybd24n vyd30n, vybd30n vyd36n this list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under replacement parts on page 23 of this manual. Key part number for no. Vyd18n vybd18n vyd24n vy...

  • Page 28: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 28 104342 illustrated parts breakdown thermostatically- controlled models vyd18nt vyd24nt vyd30nt 12 1 2 18 16 17 20 10 9 5 11 4 7 6 19 8 21 13 19 14 19 19 3 15 17 19.

  • Page 29: Owner’S Manual

    Owner’s manual 29 104342 this list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under replacement parts on page 23 of this manual. Parts list vyd18nt vyd24nt vyd30nt key vyd18nt vyd24nt vyd30nt no. Part number part number part number description...

  • Page 30: Vanguard Flame-Max

    Unvented natural gas log heater vanguard flame-max ® 30 104342 technical service you may have further questions about in- stallation, operation, or troubleshooting. If so, contact desa international’s techni- cal service department at 1-800-desa log (1-800-337-2564). You can also visit desa internat...

  • Page 31: Owner’S Manual

    Owner’s manual 31 104342 notes _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...

  • Page 32: Warranty Information

    Limited warranty vent-free natural gas log heaters desa international warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all ap...