Vanguard Flame-Max VYS18PWA Operating And Installation Manual - Vanguard

Manual is about: UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

Summary of Flame-Max VYS18PWA

  • Page 1

    Unvented (vent-free) propane/lp gas log heater ® save this manual for future reference. Warning: if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life. — do not store or use gasoline or other flammable va...

  • Page 2: Vanguard

    2 105190 unvented propane/lp gas log heater vanguard danger: carbon monoxide poisoning may lead to death! Carbon monoxide poisoning: early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get...

  • Page 3: Owner’S Manual

    3 105190 owner’s manual 13. Do not use this heater to cook food or burn paper or other objects. 14. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas...

  • Page 4: Vanguard

    4 105190 unvented propane/lp gas log heater vanguard providing adequate ventilation the following are excerpts from national fuel gas code ansi z223.1/nfpa 54, sec- tion 5.3, air for combustion and ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. ...

  • Page 5: Owner’S Manual

    5 105190 owner’s manual determining fresh-air flow for heater location determining if you have a confined or unconfined space use this work sheet to determine if you have a confined or unconfined space. Space: includes the room in which you will install heater plus any adjoining rooms with doorless ...

  • Page 6: Vanguard

    6 105190 unvented propane/lp gas log heater vanguard air for combustion and ventilation continued ventilation air ventilation air from inside building this fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent ope...

  • Page 7: Owner’S Manual

    7 105190 owner’s manual installation and clearances (vent-free operation only) warning: maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall. Warning: never install the heater • in a bedroom or bathroom un- less installed as a vented ap-...

  • Page 8: Vanguard

    8 105190 unvented propane/lp gas log heater vanguard installation continued minimum noncombustible material clearances if not using mantel note: if using a mantel, proceed to if using mantel. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fire...

  • Page 9: Owner’S Manual

    9 105190 owner’s manual installation continued mantel clearances in addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood. Determining minimum...

  • Page 10: Vanguard

    10 105190 unvented propane/lp gas log heater vanguard installation continued installing heater base assembly warning: if installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and gu...

  • Page 11: Owner’S Manual

    11 105190 owner’s manual 9. Drill holes at marked locations using 3/16" drill bit. 10. Attach base assembly to fireplace floor using two masonry screws (in hardware package). Aut o of f on o f f p il ot o n h i l o h i l o installation continued figure 11 - attaching flexible gas hose to heater figu...

  • Page 12: Vanguard

    12 105190 unvented propane/lp gas log heater vanguard installation continued figure 15 - gas connection * purchase the optional csa design-certified equipment shutoff valve from your dealer. See accessories, page 24. ** minimum inlet pressure for purpose of input adjustment. 3" minimum sediment trap...

  • Page 13: Owner’S Manual

    13 105190 owner’s manual on position off position installation continued figure 16 - equipment shutoff valve open closed equipment shutoff valve figure 17 - checking gas joints test pressures equal to or less than 1/2 psig (3.5 kpa) 1. Close equipment shutoff valve (see figure 16). 2. Pressurize sup...

  • Page 14: Vanguard

    14 105190 unvented propane/lp gas log heater vanguard o f f pil ot o n l o i h auto off on operating heater for your safety read before lighting warning: if you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. T...

  • Page 15: Owner’S Manual

    15 105190 owner’s manual operating heater continued 8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • if control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: if pilot goes out, ...

  • Page 16: Vanguard

    16 105190 unvented propane/lp gas log heater vanguard important: this remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down. Important: the hand-held re- ...

  • Page 17: Owner’S Manual

    17 105190 owner’s manual troubleshooting warning: turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. Caution: never use a wire, needle, or similar object to clean ods/pilot. This can damage ods/ pilot unit. Possible cause 1. Ignitor elect...

  • Page 18: Vanguard

    18 105190 unvented propane/lp gas log heater vanguard observed problem burner does not light after ods/pilot is lit delayed ignition burner burner backfiring during combustion slight smoke or odor during initial operation moisture/condensation noticed on windows heater produces a whistling noise whe...

  • Page 19: Owner’S Manual

    19 105190 owner’s manual troubleshooting continued warning: if you smell gas • shut off gas supply. • do not try to light any appliance. • do not touch any electrical switch; do not use any phone in your building. • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’...

  • Page 20: Vanguard

    20 105190 unvented propane/lp gas log heater vanguard specifications vintage oak vintage oak 18" 24” and 30” btu (variable) 17,500/27,000 19,000/31,500 type gas propane/lp only propane/lp only ignition piezo piezo pressure manifold 8.0" w.C. 8.0" w.C. Inlet gas pressure (in. Of water) maximum 14" 14...

  • Page 21: Owner’S Manual

    21 105190 owner’s manual cleaning and maintenance warning: turn off heater and let cool before cleaning. Caution: you must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied servi...

  • Page 22: Vanguard

    22 105190 unvented propane/lp gas log heater vanguard illustrated parts breakdown vintage oak log models vys18pwa, vys24pwa, vys30pwa 13 13 14 22 13 8 18 1 7 6 9 12 23 4 5 16 15 17 3 11 2 10 10 19 24 19 20 21 o f f p il ot o n h i l o o f f p il ot o n h i l o.

  • Page 23: Owner’S Manual

    23 105190 owner’s manual parts list vintage oak log models vys18pwa, vys24pwa, vys30pwa this list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under replacement parts on page 20 of this manual. Key part number for no. Vys18pwa vys24pwa vys30pwa ...

  • Page 24: Vanguard

    24 105190 unvented propane/lp gas log heater vanguard accessories purchase these heater accessories from your local dealer. If they can not supply these accessories, call desa international at 1-866-672-6040 for referral informa- tion. You can also write to the address listed on the back page of thi...

  • Page 25: Owner’S Manual

    25 105190 owner’s manual notes _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...

  • Page 26: Warranty Information

    Keep this warranty warranty information always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or i...