  • Page 1

    For more information, visit www.Desatech.Com warning: if the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. For use only with a listed gas-fired unvented decorative room heater not to exceed 40,000 btu/hr...

  • Page 2: Agency Or The Gas Supplier.

    Www.Desatech.Com 105604-01k warning: improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, serv...

  • Page 3: Safety Information

    Www.Desatech.Com 105604-01k 3 safety information warning: this product con- tains and/or generates chemicals known to the state of california to cause cancer or birth defects or other reproductive harm. Important: read this owner’s manual carefully and completely before trying to assemble, operate o...

  • Page 4: Local Codes

    Www.Desatech.Com 105604-01k 4 5. Vent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly. See air for combustion and ventila- tion, page 6. 6. Do not run firebox • where flammable liquids or vapors are used or stored • under dusty conditions 7. Do not use...

  • Page 5: Product

    Www.Desatech.Com 105604-01k 5 12 1 / 2 " 2 3 / 4 " 1 1 / 2 " 9 3 / 4 " 4 5 / 8 " 2 1 / 2 " 6" 32 3 / 16 " 33 11 / 16 " figure 2 - firebox side view gas line access standoffs (models fb3nca and nlfb3nc only) electrical access hole electrical access hole with bushing 22 1 / 2 " 16 11 / 16 " 13 1 / 4 "...

  • Page 6: Air For Combustion

    Www.Desatech.Com 105604-01k 6 air for combustion and ventilation warning: this firebox shall not be installed in a confined space or unusually tight construc- tion unless provisions are provid- ed for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air...

  • Page 7: Air For Combustion

    Www.Desatech.Com 105604-01k determining fresh-air flow for heater location determining if you have a confined or unconfined space use this work sheet to determine if you have a confined or unconfined space. Space: includes the room in which you will install heater plus any adjoining rooms with doorl...

  • Page 8: Air For Combustion

    Www.Desatech.Com 105604-01k 8 air for combustion and ventilation continued ventilation air ventilation air from inside building this fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12"...

  • Page 9: Installation

    Www.Desatech.Com 105604-01k installation continued figure 6 - minimum clearance for combustible to wall *minimum 16" from side wall example * mantel clearances for built-in installation if placing custom mantel above built-in firebox, you must meet the minimum allowable clearance between mantel shel...

  • Page 10: Installation

    Www.Desatech.Com 105604-01k 10 installing blower accessory (models fb32ca and nlfb32c only) you may install blower accessory ga3750a with conventional installation (below) or with built-in installation (page 11) with models fb32ca and nlfb32c only. Conventional installation of blower accessory notic...

  • Page 11: Installation

    Www.Desatech.Com 105604-01k 11 7. Plug in blower power cord. A. If your firebox is installed as a freestanding unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1 / 2 " hole in the floor support on the exit ...

  • Page 12: Installation

    Www.Desatech.Com 105604-01k 1 installing log heater in firebox caution: do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information. Caution: do not pick up log base assembly by burners. This could damage burners. Only handle ...

  • Page 13: Installation

    Www.Desatech.Com 105604-01k 13 installation continued firebox installation using optional accessory mantels this firebox may be installed using the corner or cabinet mantel with hearth base accessory against a wall in your home. A trim kit is included with each mantel accessory (see accessories, pag...

  • Page 14

    Www.Desatech.Com 105604-01k 14 illustrated parts breakdown models fb32nca and nlfb32nc 5 14 16 16 16 13 15 17 17 17 16 6 1 7 16 18 10 8 20 12 19 9 4* 2* 3* 2* 16 11 18.

  • Page 15: Parts List

    Www.Desatech.Com 105604-01k 15 key no. Part no. Description qty. 1 1018-03 firebox top • • 1 10188-01 firebrick retainer • 3 3 101-04 rear firebrick • 1 4 1013-04 side firebrick • • 5 1030-01 outer casing • • 1 6 10308-01 outer shell base • • 1 ** firebox wrapper • • 1 8 103-01 assembly screen • • 1...

  • Page 16: Illustrated Parts Breakdown

    Www.Desatech.Com 105604-01k 16 illustrated parts breakdown models fb32ca and nlfb32c 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 4* 2* 3* 2* 16 11 18 18.

  • Page 17: Parts List

    Www.Desatech.Com 105604-01k 1 parts list this list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under replacement parts on page 18 of this manual. Key no. Part no. Description qty. 1 1018-03 firebox top • • 1 10188-01 firebrick retainer • 3 3 1...

  • Page 18: Replacement Parts

    Www.Desatech.Com 105604-01k 18 replacement parts note: use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts under warranty contact authorized dealers of this product. If they can’t supply original replacement part(s), call desa heatin...

  • Page 19: Accessories

    Www.Desatech.Com 105604-01k 1 accessories continued wall cabinet mantel and base accessory with fireplace perimeter trim (not shown) w32au - 32" unfinished, traditional design w32aos - 3" light oak finish, traditional design cma311w - 3" painted white, traditional design with dentil molding cma306fa...

  • Page 20: Warranty Information

    01 industrial drive p.O. Box 0004 bowling green, ky 410-004 www.Desatech.Com 105604-01 rev. K 0/06 not a upc warranty information keep this warranty model serial no. Date purchased always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specif...