Vanguard SDVBN Operation And Installation Manual

Manual is about: CAST IRON STOVE AND DIRECT-VENT (FREESTANDING FIREPLACE HEATER) BURNER SYSTEM

Summary of SDVBN

  • Page 1

    Cast iron stove and direct-vent (freestanding fireplace heater) burner system ® owner’s operation and installation manual natural gas burner system model sdvbn(a) propane/lp gas burner system model sdvbp(a) remote ready save this manual for future reference. For your safety what to do if you smell g...

  • Page 2: Sdvbn(A) and Sdvbp(A)

    2 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) safety information 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/lp burner system, do n...

  • Page 3: Owner’S Manual

    3 105499 owner’s manual p il o t lo hi off on on off auto product identification install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current national fuel gas code ans z223.1, also known as nfpa 54* (usa) or the current can/cga- b149[.1 o...

  • Page 4: Sdvbn(A) and Sdvbp(A)

    4 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) location and space requirements determine the safest and most efficient loca- tion for your vanguard cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat ou...

  • Page 5: Owner’S Manual

    5 105499 owner’s manual pallet wood bolted to bottom of stove body stove body assembly 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body. The bottom pieces of pallet wo...

  • Page 6: Sdvbn(A) and Sdvbp(A)

    6 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) cast iron stove and direct-vent burner system assembly continued figure 12 - attaching stove door step bolt door hinge threaded hole stove door stove bottom bolt shoulder adjusting nut bolt stop catch bolt door claw door figure 13 - ...

  • Page 7: Owner’S Manual

    7 105499 owner’s manual warning: never touch the blower wheel while in operation. 7. Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control. Warning: failure to position the parts in accordance with sup- plied diagrams or f...

  • Page 8: Sdvbn(A) and Sdvbp(A)

    8 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) location of vent termination when locating vent termination, it is impor- tant to observe the minimum clearances shown in figure 18, page 9. *check with local codes or with the current can/cga b149[.1 or .2] installation codes for ca...

  • Page 9: Owner’S Manual

    9 105499 owner’s manual fixed closed openable fixed closed openable v v v v v v v v x x v x g g j f b b k n h i a n e l d b m a c b v v a g g b termination cap air supply inlet gas meter restricted area (termination prohibited) a = clearance above grade, veranda, porch, deck, or balcony [*12 inches ...

  • Page 10: Sdvbn(A) and Sdvbp(A)

    10 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) warning: read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting ...

  • Page 11: Owner’S Manual

    11 105499 owner’s manual installation for horizontal termination 1. Determine the route your horizontal venting will take. Note: the location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. Snorkel ...

  • Page 12: Sdvbn(A) and Sdvbp(A)

    12 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) up venting installation continued (framing detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) vent opening combustible wall vent opening noncombustible wall figure 22 - vent opening requirements 3. Attach vent pipe assembly to the bu...

  • Page 13: Owner’S Manual

    13 105499 owner’s manual venting installation continued figure 26 - horizontal termination configuration for rigid venting figure 27 - horizontal termination configuration for rigid venting using one 90 ° elbow horizontal venting vertical (v) horizontal (h) 37" min. 29" max. (30 ° and 90 ° only, no ...

  • Page 14: Sdvbn(A) and Sdvbp(A)

    14 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) flat ceiling installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in figure 22 on page 12 using frami...

  • Page 15: Owner’S Manual

    15 105499 owner’s manual venting installation continued figure 31 - installing firestop if area above is not a room, install firestop below framed hole. If area above is a room, install firestop above framed hole. Continued 3. Cut a hole in the roof using the locating hole as a center point. (cover ...

  • Page 16: Sdvbn(A) and Sdvbp(A)

    16 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) venting with two 90 ° elbows vertical (v 1 ) horizontal (h) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: vertical (v 1 ) + vertical (v 2 ) = 20' max. Figure 36 - vertical rigid venting configuration using...

  • Page 17: Owner’S Manual

    17 105499 owner’s manual figure 37 - vertical rigid venting configuration with no horizontal run venting installation continued vertical venting v = 40' max. Rvkbk kit shown note: install restrictor into 4" collar of burner system as shown. High altitude installation your vanguard cast iron stove an...

  • Page 18: Sdvbn(A) and Sdvbp(A)

    18 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) figure 39 - gas connection * the a.G.A. Design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. Caution: use only new, black iron or steel pipe. Inter- nally-tinned copper tu...

  • Page 19: Owner’S Manual

    19 105499 owner’s manual pressure testing gas supply piping system test pressures in excess of 1/2 psig (3.5 kpa) 1. Disconnect burner system and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kpa) will damage burner system gas regulator. 2. C...

  • Page 20: Sdvbn(A) and Sdvbp(A)

    20 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) stove and direct-vent burner system installation continued test pressures equal to or less than 1/2 psig (3.5 kpa) 1. Close manual shutoff valve (see fig- ure 41). 2. Pressurize supply piping system by ei- ther opening propane/lp su...

  • Page 21: Owner’S Manual

    21 105499 owner’s manual stove and direct-vent burner system installation continued installing optional wall mounted thermostat - gwmt1 warning: installation must be done by a qualified installer familiar with low voltage wiring procedures. Warning: do not connect this thermostat to any electrical s...

  • Page 22: Sdvbn(A) and Sdvbp(A)

    22 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) removing/replacing glass door caution: do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see replacement parts, page 31. 1. Remove ...

  • Page 23: Owner’S Manual

    23 105499 owner’s manual each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding burner system. Do not use if any log(s) are broken (...

  • Page 24: Sdvbn(A) and Sdvbp(A)

    24 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) to turn off gas to appliance 1. Open lower louver panel. 2a. Turn on/off switch to “off”. 2b. If using optional hand-held re- mote: set selector switch in the off position to prevent draining battery. 3. Turn off all electrical powe...

  • Page 25: Owner’S Manual

    25 105499 owner’s manual 1. After lighting, let pilot flame burn for about one minute. Turn gas control knob on the control valve to on posi- tion. Turn variable control knob any- where between hi and lo. Slide the selector switch to the remote posi- tion. Note: the burners may light if hand-held re...

  • Page 26: Sdvbn(A) and Sdvbp(A)

    26 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) inspecting burners check pilot flame pattern and burner flame patterns often. Pilot assembly the pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualif...

  • Page 27: Owner’S Manual

    27 105499 owner’s manual cleaning and maintenance warning: turn off burner system and let cool before cleaning. Caution: you must keep control areas, burners, and cir- culating air passageways of burner system and stove clean. Inspect these areas of burner system and stove before each use. Have burn...

  • Page 28: Sdvbn(A) and Sdvbp(A)

    28 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) troubleshooting note: all troubleshooting items are listed in order of operation. Warning: turn off burner system and let cool before ser- vicing. Only a qualified service person should service and repair burner system or stove. Cau...

  • Page 29: Owner’S Manual

    29 105499 owner’s manual observed problem burner does not light after pilot is lit delayed ignition burner burner backfiring during combustion slight smoke or odor during initial operation burner system produces a whistling noise when burner is lit glass soots burner system produces a clicking/ticki...

  • Page 30: Sdvbn(A) and Sdvbp(A)

    30 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) troubleshooting continued warning: if you smell gas • shut off gas supply. • do not try to light any appliance. • do not touch any electrical switch; do not use any phone in your building. • immediately call your gas supplier from a...

  • Page 31: Owner’S Manual

    31 105499 owner’s manual service hints when gas pressure is too low • pilot will not stay lit • burners will have delayed ignition • burner system will not produce speci- fied heat • propane/lp gas supply might be low (propane/lp units only) when gas quality is bad • pilot will not stay lit • burner...

  • Page 32: Sdvbn(A) and Sdvbp(A)

    32 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) specifications sdvbn(a) sdvbp(a) 16,000-22,000 btu/h 14,000-20,000 btu/h gas type natural propane/lp ignition piezo piezo manifold pressure 3.5" w.C. 10.0" w.C. Minimum inlet supply pressure 4.5" w.C. 11.0" w.C. Thermal efficiency 7...

  • Page 33: Owner’S Manual

    33 105499 owner’s manual accessories purchase these stove and burner system accessories from your local dealer. If they can not supply these accessories, call desa international’s sales department at 1-800- 432-2382. For information. You can also write to the address listed on the back page of this ...

  • Page 34: Sdvbn(A) and Sdvbp(A)

    34 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) illustrated parts breakdown sdvbn(a) sdvbp(a) lo h i p il o t off on 24 27 19 20 21 23 26-1 26-4 26-2 26-3 29 30 4 25 1 2 4 4 7 8 9 10 11 13 12 31 15 16 17 18 22 22 28 5 32 3 14 6.

  • Page 35: Owner’S Manual

    35 105499 owner’s manual key no. Part number description qty. 1 105478-01br firebox assembly 1 2 m11084-26 screw, hex 2 3 105482-01ck rear cover 1 4 m11084-39 screw, hex 12 5 103587-02ck switch plate 1 6 099998-01 on/off switch 1 7 103284-04 wire harness 1 8 104491-01 relief cover 1 9 104518-01 reli...

  • Page 36: Sdvbn(A) and Sdvbp(A)

    36 ® cast iron stove and burner system 105499 sdvbn(a) and sdvbp(a) illustrated parts breakdown amity™ scivf(*) series pscivf(*) series (* indicates color suffix designation) 1 2 5 8 7-4 6 5 5 7-1 7-2 5 4 7-3 3 amity ™ stove chassis.

  • Page 37: Owner’S Manual

    37 105499 owner’s manual parts list amity™ scivf(*) series pscivf(*) series (* indicates color suffix designation) this list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under replacement parts on page 31 of this manual. * included in hardware ki...

  • Page 38: Warranty Information

    Vanguard limited warranty direct-vent burner system and amity ™ stove chassis desa international warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintaine...