Vanguard VI33NR Owner's operation and installation manual - Installation
111285-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
Top Brass Trim
Side Brass
Trim
Set Screws
Adjusting
Plate
Shim
Figure 10 - Assembling Brass Trim
Slot
Slot
Mitered
Edge
INSTALLATION
Continued
Figure 11 - Installing Hood to Firebox
INSTALLING HOOD
Install hood to top of firebox as shown in Figure 11. Use 7 Phillips
screws provided.
Screws
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceil-
ing, and adjoining wall.
Carefully follow the instructions below. This will ensure safe
installation.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace cabinet to any com-
bustible material and wall should follow diagram in Figure 12.
Example:
The face of a mantel, bookshelf, etc. is made of
combustible material and protrudes 3
1
/
2
" from the wall. This
combustible material must be 4" from the side of the fireplace
opening (see Figure 12).
B. Clearances from the top of the fireplace opening to the ceiling
should not be less than 42 inches.
Figure 12 - Minimum Clearance for Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
FIREPLACE INSERT INSTALLATION INTO
MASONRY FIREPLACE
Installation of this fireplace insert involves installing fireplace insert
into an existing masonry fireplace. If using a mantel above the
fireplace, you must follow the clearances shown in Figure 14. Follow
the instructions below to install the fireplace insert in this manner.
Minimum
Insert
Fireplace Opening
Height
25
9
/
16
"
26
1
/
4
"
Front Width
34
5
/
16
"
35"
Depth
16
11
/
16
"
17
1
/
4
"
1.
Use dimensions shown in Figure 13 for the masonry fireplace
opening.
2.
Install and properly ground GA3555, three-prong 120 volt elec-
trical outlet, in fireplace insert. Follow instructions included
in kit (see Accessories, page 28).
3.
Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location, page 11.
4.
Carefully set fireplace insert in front of masonry fireplace with
back of insert inside wall opening.
5.
Attach flexible gas line to gas supply. See Connecting Fire-
place Insert to Gas Supply, pages 11 and 12.
6.
Plug electrical cord into electrical outlet installed in step 2.
7.
Carefully place fireplace insert into masonry fireplace.
35"
17
1
/
4
"
26
1
/
4
"
Figure 13 - Rough Opening for Installing in Masonry Fireplace
INSTALLATION
Installing Surround Kit (GS38 or GS43) (Cont.)
Installing Hood
Installation Clearances
Fireplace Insert Installation Into Masonry Fireplace