Vanguard VMH26TP Owner's Operation And Installation Manual

Manual is about: VENT-FREE PROPANE/LP GAS COMPACT CLASSIC HEARTH FIREPLACE

Summary of VMH26TP

  • Page 1

    Save this manual for future reference. Owner’s operation and installation manual vent-free propane/lp gas compact classic hearth fireplace ® 14,000 to 26,000 btu/hr with thermostat ® shown with optional cabinet mantel/hearth base accessory vmh26tp this appliance may be installed in an aftermarket* m...

  • Page 2: Contents

    2 102886 contents section page safety information continues on next page safety information ................................................................................... 2 product identification .............................................................................. 4 local codes .........

  • Page 3: Safety

    3 102886 safety information continued warning icon g 001 warnings continued warning: any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do ...

  • Page 4: Product

    4 102886 product identification local codes install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of the national fuel gas code ansi z223, also known as nfpa 54*. *available from: american national standards institute, inc. 1430 broadway n...

  • Page 5: Assembly

    5 102886 assembly assembling fireplace tools required: phillips screwdriver, 5/16" hex wrench, and slotted screwdriver installing log 1. Remove back log, branch, and hood from log box. Discard protective packaging. 2. Remove two shipping screws above screen (see figure 2). 3. Lift screen up and pull...

  • Page 6: Air For

    6 102886 air for combustion and ventilation warning icon g 001 warning this heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning applian...

  • Page 7: Air For

    7 102886 air for combustion and ventilation continued determining fresh-air flow for fireplace location determining if you have a confined or unconfined space use this worksheet to determine if you have a confined or unconfined space. Space: includes the room in which you will install fireplace plus...

  • Page 8: Air For

    8 102886 air for combustion and ventilation continued figure 4 - ventilation air from inside building shown with optional mantel warning icon g 001 warning if the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilati...

  • Page 9: Air For

    9 102886 air for combustion and ventilation continued figure 5 - ventilation air from outdoors shown with optional mantel ventilation air from outdoors provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within ...

  • Page 10: Installation

    10 102886 installation check gas type use only propane/lp gas. If your gas supply is not propane/lp, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace. Installation items before installing fireplace, make sure you have the items listed below. Notice a qualifi...

  • Page 11: Caution

    11 102886 figure 7 - mounting clearances as viewed from front of fireplace shown with optional mantel warning icon g 001 caution if you install the fireplace in a home garage • fireplace pilot and burner must be at least 18 inches above floor. • locate fireplace where moving vehicle will not hit it....

  • Page 12: Installing

    12 102886 installing continued 36 5/8" 25 7/8" 51 3/4" 26 7/8" figure 9 - rough opening for installing in corner 2. An optional blower accessory is available (see accessories, page 32). There are two options for connecting blower to electrical source. Option one: have a licensed electrician install ...

  • Page 13: Installing

    13 102886 installing continued continued 6. Attach flexible gas line to fireplace gas regulator. See connecting fireplace to gas supply, page 17. 7. If the optional blower has been installed connect blower to electrical source. Option one: route blower electrical cord through side or rear access doo...

  • Page 14: Installing

    14 102886 installing continued figure 12 - attaching brass trim to fireplace shoulder screws assembled brass trim optional mantel installation note: refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. Refer to instructions on...

  • Page 15: Installing

    15 102886 attaching wood base to solid floor for attaching base to solid floors (concrete or masonry) note: floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete...

  • Page 16: Connecting

    16 102886 connecting to gas supply figure 16 - external regulator with vent pointing down notice a qualified service person must connect fireplace to gas supply. Follow all local codes. Warning icon g 001 caution never connect fireplace directly to the propane/lp supply. This fireplace requires an e...

  • Page 17: Connecting

    17 102886 continued connecting to gas supply continued figure 18 - removing twig support from fireplace connecting fireplace to gas supply installation items needed • phillips screwdriver • sealant (resistant to propane gas, not provided) 1. Remove fireplace screen. Remove two screws that hold firep...

  • Page 18: Checking

    18 102886 checking gas connections pressure testing gas supply piping system test pressures in excess of 1/2 psig 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator. 2. Cap off open end of gas...

  • Page 19: Checking

    19 102886 on position off position test pressures equal to or less than 1/2 psig 1. Close manual shutoff valve (see figure 20). 2. Pressurize supply piping system by either using compressed air or opening propane/lp supply tank valve. 3. Check all joints from propane/lp supply tank to manual shutoff...

  • Page 20: Operating

    20 102886 operating fireplace for your safety read before lighting continued warning icon g 001 warning if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Lighting instructions 1. Stop! Read the safety information...

  • Page 21: Operating

    21 102886 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, stop! Follow “b” in the safety information at the top of page 20. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise c-clockwise to the pilot posit...

  • Page 22: Operating

    22 102886 to turn off gas to appliance shutting off fireplace 1. Turn control knob clockwise clockwise to the off position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting off burner only (pilot stays lit) 1. Turn control knob clockwise clockwise to the pilot ...

  • Page 23: Inspecting

    23 102886 inspecting burner thermocouple pilot burner figure 24 - correct pilot flame pattern thermocouple pilot burner figure 25 - incorrect pilot flame pattern check pilot flame pattern and burner flame pattern often. Pilot flame pattern figure 24 shows a correct pilot flame pattern. Figure 25 sho...

  • Page 24: Notice

    24 102886 burner flame pattern figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log. Note: when using the fireplace the first...

  • Page 25: Cleaning

    25 102886 cleaning and maintenance ods/pilot and burner • use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. Cabinet air passageways • use a vacuum cleaner or pressurized air to clean. Exterior • use a soft cloth dampened with a mild soap and water mixture. Wipe the cabin...

  • Page 26: Trouble-

    26 102886 continued remedy 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to pilot position 3. Press in control knob while in pilot position 4. Continue holding down control knob. Repeat ig- niting operation until air is removed 5. Contact local propane/ lp gas company 6. Cl...

  • Page 27: Trouble-

    27 102886 trouble- shooting continued observed problem burner does not light after ods/pilot is lit delayed ignition of burner burner backfiring during combustion yellow flame during burner combustion slight smoke or odor during initial operation fireplace produces a whistling noise when burner is l...

  • Page 28: Trouble-

    28 102886 trouble- shooting continued warning icon g 001 warning if you smell gas • shut off gas supply. • do not try to light any appliance. • do not touch any electrical switch; do not use any phone in your building. • immediately call your gas supplier from a neighbor’s phone. Follow the gas supp...

  • Page 29: Technical

    29 102886 technical service you may have further questions about installation, operation, or troubleshooting. If so, contact desa international’s technical service department at 1-800-323-5190. Specifications service hints replacement parts btu (variable) 14,000/26,000 type gas propane/lp only ignit...

  • Page 30: Vmh26Tp

    30 102886 12-1 12-2 23 29 32 36 37 13 7 33 11 8 10 17 17 8 7 30 3 1 2 9 19 6 22 31 21 40 27 38 39 16 15 18 24 28 5 34 26 25 20 35-1 35-2 12 24 12-1 25 14 4 vmh26tp.

  • Page 31: Parts List

    31 102886 parts list this list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under replacement parts on page 29 of this manual. Key vmh26tp no. Part no. Description qty. 1 102633-01 outer casing top 1 2 102624-02 outer casing 1 3 099230-02 sho...

  • Page 32: Accessories

    32 102886 accessories purchase these fireplace accessories from your local dealer. If they cannot supply these accessories call desa international’s sales department at 1-800-458-2472 for referral information. You can also write to the address listed on the back page of this manual. Cabinet mantel w...

  • Page 33: Notes

    33 102886 notes _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ____________________________...

  • Page 34: Notes

    34 102886 notes _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ____________________________...

  • Page 35: Notes

    35 102886 notes _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ____________________________...

  • Page 36: Warranty Information

    2701 industrial drive p.O. Box 90004 bowling green, ky 42102-9004 102886-01 rev. D 06/97 limited warranty vent-free propane/lp gas compact classic hearth ‚ fireplace desa international warrants this product to be free from defects in materials and components for three (3) years and five (5) years on...