Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not light, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, turn off gas supply and contact
a qualified service person or gas supplier
for repairs.
Note: If pilot goes out, repeat steps 3
through 7.
8. Push in and turn control knob counter-
clockwise
to the HI position. Both
burners should light. Set control knob to
desired setting.
9. To leave pilot lit and shut off burners only:
turn control knob clockwise
to the
HI position. Press in and turn control knob
clockwise
to the PILOT position.
Figure 32 - Pilot
Ignitor Electrode
Thermocouple
Pilot
Burner
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any
heat setting and flame height desired, by sim-
ply turning the control knob until that setting
is attained. Even the lowest setting provides
realistic flames and glowing embers from two
burners. Selecting higher settings produces
greater heat output. This results in increased
heating comfort.
WARNING: Do not operate
heater between locked posi-
tions.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
1. Press in and turn control knob clockwise
to the HI position.
2. Turn the control knob clockwise
to
the PILOT position.
3. Press in control knob and turn clockwise
to the OFF position.
4. Close equipment shutoff valve (see
Figure 15), page 16.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 22.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8