Summary of Samso

  • Page 1

    1 installation— and user guide revsion 01 varde samsø.

  • Page 2

    2 congratulation on purchasing your new stove varde ovne a/s is a danish company specializing in functional, environmentally friendly and designed quality stoves. Index welcome and index page 2 technical specifications samsø page 3 regulations and approval page 4 flooring and distance page 5 chimney...

  • Page 3

    3 model samsø hight (mm) 1000 wide (mm) 487 depth (mm) 349 weight (kg) 80 effect 3-7 kw nominal output 5 kw heated area 30-105m2 efficiency 75% flue gas data: 5,5 g/sek., 340°c ved 20°c, 11 pa. Combustion chamber: (h x w x d): 260/380x200/300x300mm flue outlet Ø 15 cm (mounting hight top: ~99cm) dis...

  • Page 4

    4 important! Before lighting up your varde stove for the first time, we recommend that you read these instructions carefully and contact your local stove vendor or building authoorities to inquire about existing regulations regarding the intallation of stoves. Please follow these regulations closely...

  • Page 5

    5 flooring: if the floor on which the stove is to be placed is inflammable, the floor must be covered with non -flammable material, such as steel or glass plate, floor tiles or artifical slate, covering an area of at least 15 cm from the sides of the stove and at least 30 cm from the front of it. Re...

  • Page 6

    6 the chimney: always use a chimney with a diameter of at least 15 cm. This corresponds to a clear of 175 cm 2 . Make sure the chimney is of a sufficient height, that it draws well and that smoke does not both- er your neighbours. We recommend that you fit your chimney with a damper, allowing for dr...

  • Page 7

    7 continual fresh air a continual supply of fresh air is required in the room in wich the stove is situated. This can be achieved by installing 1-2 vents, whilst also ensur- ring that these can not be blocked. The quantity of air used for burning, is approx. 14 m³ / h. Tertiary air is constantly add...

  • Page 8

    8 how it works the grate combustion air throttel push the throttel towards right for opening. Ignition air on ashpan - open ignition air on ashpan - closed.

  • Page 9

    9 how to light and stoke a fire: the first time you light up the stove the enamel will temper, and give off some smoke and a slight smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel making it susceptible to ...

  • Page 10

    10 operation 1 2 3 4 5 6 7 8 9 1. Grate 2. Wood catch 3. Vermiculit plates 4. Ash tray 5. Cast iron door 6. Steel top 7. Throttel for ignition air 8. Combustion air throttel 9. Storage.

  • Page 11

    11 vermiculite the plates in the combustion chamber are vermiculite plates and will aventually be worn, - as will the smoke plate. Should you accidentally breah the plate, for instance by hitting it hard with a piece of wood, this does not effect the quality of the combustion. You need not re- place...

  • Page 12

    12 the new stove the first time you light up the stove the ena- mel will temper, and give off some smoke and a slight smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel making it susceptible to damage. Theref...

  • Page 13

    13 maintenance like any piece of equipment in daily use, your stove needs maintenance. The stove should only be cleaned when cold. Use a dry cloth for cleaning the exterior of the stove. Clean the interior regularly by removing ashes, soot and tar from the combustion chamber. The smoke deflector pla...

  • Page 14

    14 troubleshooting. Smoke enters the room: • not enough draugh in the chimney. • inspect the smoke pipe or the chimney for blockage. • clean the inside of the stove removing soot from the upper vermiculite / smoke (deflector) plate. • make sure the hight of the chimney is correct. The glass or the c...

  • Page 15

    15 spare parts if spare parts at any time should be needed, please chech the list below. Vermiculit set, artikel nr.: 2223506 sealings—door , artikel nr.: 10014+10008 glass, artikel nr.: 1107501 door handle, artikel nr.: 1107124 door , artikel nr.: 1107526 door (gray), artikel nr.: 1107526g glass sp...

  • Page 16

    16 test certificate (rwe).

  • Page 17

    17.

  • Page 18

    18 warranty all varde stoves go through a close quality inspection, and we take pride in always delivering products of a consistent quality. This being so, manufacturing faults may still occur, and on these we offer a 5 year warranty. The warranty does not include: · wearing parts, such as the vermi...

  • Page 19