Summary of Uniq

  • Page 1

    1 installation— and user guide revision 6 varde uniq.

  • Page 2

    2 congratulation on purchasing your new stove varde ovne a/s is a danish company specializing in functional, environmentally friendly and designed quality stoves. Index welcome and index page 2 technical specifications uniq 1 page 3 technical specifications uniq 13 steel page 4 technical specificati...

  • Page 3

    3 model 1801 uniq 1 hight (mm) 1044 wide (mm) 484 depth (mm) 364 weight (kg) 110 effect 3-6 w nominal output 5,4 kw heated area 30-105m2 efficiency 76% flue gas data: 5,5 g/sek., 288°c ved 20°c, 12 pa. Combustion chamber: (h x w x d): 380 x 350 x 250mm flue outlet Ø 15 cm distance to non-flammable: ...

  • Page 4

    4 technical specifications uniq 13 model 18013 uniq 13 hight (mm) 1160 wide (mm) 484 depth (mm) 364 weight (kg) 110 effect 3-6 w nominal output 5,4 kw heated area 30-105m2 efficiency 76% flue gas data: 5,5 g/sek., 288°c ved 20°c, 12 pa. Combustion chamber: (h x w x d): 380 x 350 x 250mm flue outlet ...

  • Page 5

    5 model 1802 uniq 2 steel hight (mm) 1044 wide (mm) 484 depth (mm) 364 weight (kg) 104 effect 3-6 w nominal output 5,4 kw heated area 30-105m2 efficiency 76% flue gas data: 5,5 g/sek., 288°c ved 20°c, 12 pa. Combustion chamber: (h x w x d): 380 x 350 x 250mm flue outlet Ø 15 cm distance to non-flamm...

  • Page 6

    6 important! Before lighting up your varde stove for the first time, we recommend that you read these instructions carefully and contact your local stove vendor or building authoorities to inquire about existing regulations regarding the intallation of stoves. Please follow these regulations closely...

  • Page 7

    7 flooring: if the floor on which the stove is to be placed is inflammable, the floor must be covered with non -flammable material, such as steel or glass plate, floor tiles or artifical slate, covering an area of at least 15 cm from the sides of the stove and at least 30 cm from the front of it. Re...

  • Page 8

    8 connection of flue pipe: the stove is mounted with flue adap- tor on top or on the rear side. When mounting on the rear side the flue adaptor and cover switch places. The cast iron cover is placed in the hole on in top of the cast iron top. The chimney: always use a chimney with a diameter of at l...

  • Page 9

    9 continual fresh air a continual supply of fresh air is required in the room in wich the stove is situated. This can be achieved by installing 1-2 vents, whilst also ensur- ring that these can not be blocked. The quantity of air used for burning, is approx. 20 m³ / h. Overheating occors if too much...

  • Page 10

    10 how it works shake grate. The shake grate is placed in the bottom of the chamber. Optart 1 pull the handle towards yourself, so that the shake grate is fully open. Move the handle 2 move the aircontrol handle all the way to the right. 3 open the door your stove is now rea- dy, in start position. ...

  • Page 11

    11 how to light and stoke a fire the first time you light up the stove, the enamel will temper and give off some smoke and a slightly burnt smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel, making it suscep...

  • Page 12

    12 operation 7 6 5 1 4 3 2 9 8 10 1. Shake grate 2. Wood catch 3. Vermiculit plates 4. Ash tray 5. Cast iron door 6. Cast iron top 7. Cast irion cover 8. Handle for air regulation 9. Storgage 10. Plinth.

  • Page 13

    13 vermiculite the plates in the combustion chamber are called vermiculite plates and will eventually become worn, as will the smoke guide plate. Accidental breakage of a plate, for instance by hitting it hard with a piece of wood, will not affect the quality of the combustion. You do not need to re...

  • Page 14

    14 the new stove the first time you light up the stove the ena- mel will temper, and give off some smoke and a slight smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel making it susceptible to damage. Theref...

  • Page 15

    15 maintenance like any piece of equipment in daily use, your stove needs maintenance. The stove should only be cleaned when cold. Use a dry cloth for cleaning the exterior of the stove. Clean the interior regularly by removing ashes, soot and tar from the combustion chamber. The smoke deflector pla...

  • Page 16

    16 troubleshooting. Smoke enters the room • not enough draught in the chimney. • inspect the flue pipe or the chimney for blockage. • make sure the height of the chimney is correct. The glass or the chimney soots up • the wood is too moist. • not enough secondary air is supplied to the combustion pr...

  • Page 17

    17 spare parts if spare parts at any time should be needed, please chech the list below. Vermiculit set, item no.: 1802506 vermiculit set - light, item no.: 1801506 glass inside combustion chamber, item no.: 1801504 glas - sidepanels, item no.: 1801505 sealings—door , item no.: 10014+10008 door , it...

  • Page 18

    18 continual fresh air. A contiual supply of fresh air is reguired in the room in witch the stove is situated. This can be achived by installing 1 or 2 vents, whilst also ensuring that these can not be blocked. Combustion air supply (extra) when a stove is installed in a room, the requirements to ai...

  • Page 19

    19.

  • Page 20

    20

  • Page 21

    21 warranty all varde stoves go through a close quality inspection, and we take pride in always delivering products of a consistent quality. This being so, manufacturing faults may still occur, and on these we offer a 5 year warranty. The warranty does not include: · wearing parts, such as the vermi...