Varde Vision Installation And User Manual

Summary of Vision

  • Page 1

    1 installation— and user guide revision 3 varde vision.

  • Page 2

    2 congratulation on purchasing your new stove varde ovne a/s is a danish company specializing in functional, environmentally friendly and designed quality stoves. Index welcome and index page 2 technical specifications vision 11 page 3 technical specifications vision 1 page 4 regulations and approva...

  • Page 3

    3 varde vision 11 hight (mm) 1171 wide (mm) 556 depth (mm) 335 weight (kg) 110 effect 5,3-6w nominal output 6 kw heated area 45-120m2 efficiency 79 % flue gas data: 5,8g/sek., 265°c 20°c, 12 pa. Combustion chamber: (h x w x d): 380 x 352 x 215mm flue outlet Ø 15 cm (mounting hight top: ~1032cm) dist...

  • Page 4

    4 varde vision 1 hight (mm) 1171 wide (mm) 556 depth (mm) 335 weight (kg) 110 effect 5,3-6 w nominal output 6 kw heated area 45-120m2 efficiency 79 % flue gas data: 5,8g/sek., 265°c , 20°c, 12 pa. Combustion chamber: (h x w x d): 440 x 360 x 242 mm flue outlet Ø 15 cm (mounting hight top: ~1152cm) d...

  • Page 5

    5 important! Before lighting up your varde stove for the first time, we recommend that you read these instructions carefully and contact your local stove vendor or building authoorities to inquire about existing regulations regarding the intallation of stoves. Please follow these regulations closely...

  • Page 6

    6 flooring: if the floor on which the stove is to be placed is inflammable, the floor must be covered with non -flammable material, such as steel or glass plate, floor tiles or artifical slate, covering an area of at least 15 cm from the sides of the stove and at least 30 cm from the front of it. Re...

  • Page 7

    7 connection of flue pipe: the stove is mounted with flue adap- tor on top or on the rear side. When mounting on the rear side the flue adaptor and cover switch places. The cast iron cover is placed in the hole on top of the cast iron top. The chimney: always use a chimney with a diameter of at leas...

  • Page 8

    8 continual fresh air a continual supply of fresh air is required in the room in wich the stove is situated. This can be achieved by installing 1-2 vents, whilst also ensur- ring that these can not be blocked. The quantity of air used for burning, is approx. 20 m³ / h. Overheating occors if too much...

  • Page 9

    9 how it works — operation the shake grate is operated by moving the handle inn and out . Normaly operation of the stove. The handle should be in the inner posi- tion. The grate must be open. Ignition/ lighting your varde ovne stove 1.: open the ignition air by turning the handle 1 down. 2.: push th...

  • Page 10

    10 how to light and stoke a fire the first time you light up the stove, the enamel will temper and give off some smoke and a slightly burnt smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel, making it suscep...

  • Page 11

    11 operation 1. Shake grate 2. Vermiculit plates 3. Ash tray 4. Ignition air 5. Combustion air 6. Throttel for shake grate 7. Cast iron door 8. Top steel cover 8 7 1 3 2 4 5 6.

  • Page 12

    12 vermiculite the plates in the combustion chamber are called vermiculite plates and will eventually become worn, as will the smoke guide plate. Accidental breakage of a plate, for instance by hitting it hard with a piece of wood, will not affect the quality of the combustion. You do not need to re...

  • Page 13

    13 the new stove the first time you light up the stove the ena- mel will temper, and give off some smoke and a slight smell. We recommend that you leave doors and windows open, as airing the room will make the smell disappear. This tempering softens the enamel making it susceptible to damage. Theref...

  • Page 14

    14 maintenance like any piece of equipment in daily use, your stove needs maintenance. The stove should only be cleaned when cold. Use a dry cloth for cleaning the exterior of the stove. Clean the interior regularly by removing ashes, soot and tar from the combustion chamber. The smoke deflector pla...

  • Page 15

    15 troubleshooting. Smoke enters the room • not enough draught in the chimney. • inspect the flue pipe or the chimney for blockage. • make sure the height of the chimney is correct. The glass or the chimney soots up • the wood is too moist. • not enough secondary air is supplied to the combustion pr...

  • Page 16

    16 spare parts if spare parts at any time should be needed, please chech the list below. Vermiculit set, item no.: 1501506 glas, item no.: 1501503 locking system, item no.: 1501565 sealings—door , item no.: 10014+10008 shake grate, item no.: 65 glass spring with screws, item no.: 10024.

  • Page 17

    17 continual fresh air. A contiual supply of fresh air is reguired in the room in witch the stove is situated. This can be achived by installing 1 or 2 vents, whilst also ensuring that these can not be blocked. Combustion air supply (extra) when a stove is installed in a room, the requirements to ai...

  • Page 18

    18.

  • Page 19

    19 warranty all varde stoves go through a close quality inspection, and we take pride in always delivering products of a consistent quality. This being so, manufacturing faults may still occur, and on these we offer a 5 year warranty. The warranty does not include: · wearing parts, such as the vermi...