Varytec BAT.PAR 6 RGBUV User Manual

Manual is about: LED Spotlight

Summary of BAT.PAR 6 RGBUV

  • Page 1

    Bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight user manual.

  • Page 2

    Musikhaus thomann thomann gmbh hans-thomann-straße 1 96138 burgebrach germany telephone: +49 (0) 9546 9223-0 e-mail: info@thomann.De internet: www.Thomann.De 29.12.2017, id: 385435, 385475.

  • Page 3: Table of Contents

    Table of contents 1 general information................................................................................................................................. 6 1.1 further information.............................................................................................................

  • Page 4

    7.6 functions in 4-channel dmx mode........................................................................................... 38 7.7 functions in 5-channel dmx mode........................................................................................... 39 7.8 functions in 6-channel dmx mode........

  • Page 5

    Bat.Par 6 rgbwa bat.Par 6 rgbuv 5 led spotlight.

  • Page 6: General Information

    1 general information this manual contains important instructions for the safe operation of the unit. Read and follow the safety instructions and all other instructions. Keep the manual for future reference. Make sure that it is available to all those using the device. If you sell the unit please ma...

  • Page 7

    1.1 further information on our website (www.Thomann.De) you will find lots of further information and details on the following points: download this manual is also available as pdf file for you to download. Keyword search use the search function in the electronic version to find the topics of intere...

  • Page 8

    1.2 notational conventions this manual uses the following notational conventions: the letterings for connectors and controls are marked by square brackets and italics. Examples: [volume] control, [mono] button. 1.3 symbols and signal words in this section you will find an overview of the meaning of ...

  • Page 9

    Signal word meaning danger! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. Warning! This combination of symbol and signal word indicates a pos- sible dangerous situation that can result in death ...

  • Page 10

    Warning signs type of danger warning – danger zone. General information 10 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 11: Safety Instructions

    2 safety instructions this device is intended to be used as an electronic illumination effect using led technics. The device is designed for professional use and is not suitable for use in households. Use the device only as described in this user manual. Any other use or use under other operating co...

  • Page 12

    Danger! Danger for children ensure that plastic bags, packaging, etc. Are disposed of properly and are not within reach of babies and young children. Choking hazard! Ensure that children do not detach any small parts (e.G. Knobs or the like) from the unit. They could swallow the pieces and choke! Ne...

  • Page 13

    Danger! Electric shock caused by short-circuit always use proper ready-made insulated mains cabling (power cord) with a pro- tective contact plug. Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a regis- tered el...

  • Page 14

    Warning! Incorrect handling of lithium batteries can result in injury in the event of a short circuit, overheating or mechanical damage, lithium bat- teries can cause severe injuries. Follow the advice on the correct handling of lithium batteries in the present sec- tion. Notice! Risk of fire do not...

  • Page 15

    Notice! Operating conditions this device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations. Notice! Power supply before connecting the device, ensure that the input voltage (ac outlet)...

  • Page 16

    Notice! Risk of fire due to incorrect polarity incorrectly inserted batteries may destroy the device or the batteries. Ensure that proper polarity is observed when inserting batteries. Notice! Possible damage by leaking batteries leaking batteries can cause permanent damage to the device. Take batte...

  • Page 17

    Notice! Possible staining the plasticiser contained in the rubber feet of this product may possibly react with the coating of your parquet, linoleum, laminate or pvc floor and after some time cause permanent dark stains. In case of doubt, do not put the rubber feet directly on the floor, but use fel...

  • Page 18: Features

    3 features special features of the device: n model bat.Par 6 rgbwa: six rgbwa leds (red, green, blue, white, amber, 8 w each) n model bat.Par 6 rgbuv: six rgbuv leds (red, green, blue, uv, 8 w each) n stand-alone, master-slave or dmx mode operation n control via dmx, four different modes, with the s...

  • Page 19: Installation

    4 installation unpack and carefully check that there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the device against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable f...

  • Page 20

    Notice! Risk of overheating always ensure sufficient ventilation. The ambient temperature must always be below 40 °c (104 °f). Notice! Use of stands when mounting the device onto a stand, ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the max...

  • Page 21

    Notice! Possible data transmission errors for error-free operation make use of dedicated dmx cables and do not use ordi- nary microphone cables. Never connect the dmx input or output to audio devices such as mixers or ampli- fiers. You can install the unit in hanging or standing position. When in us...

  • Page 22

    Please note that this device must not be connected to a dimmer. Installation 22 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 23: Starting Up

    5 starting up create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards. Starting up bat.Par 6 rgbwa bat.Par 6 rgbuv 23 led spotlight.

  • Page 24

    Connect the dmx input of the device to the dmx output of a dmx controller or another dmx device. Connect the output of the first dmx device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last dmx device in the daisy chain is terminated with a re...

  • Page 25

    6 connections and operating elements connections and operating elements bat.Par 6 rgbwa bat.Par 6 rgbuv 25 led spotlight.

  • Page 26

    1 display and function buttons: [menu] activates the main menu and toggles between menu items. Closes an opened submenu. [up], [down] toggles between the menu items of a menu level, increases or decreases the displayed value by one. [enter] selects an option of the respective operating mode, confirm...

  • Page 27

    6 [switch] main switch. Turns the device on and off. 7 [battery indicator] remaining battery capacity display. When all the leds are on, the battery is fully charged. If only the red led is on, the unit must be connected to the mains again to charge as soon as possible. 8 [dmx in] dmx input. 9 [dmx ...

  • Page 28

    Remote control connections and operating elements 28 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 29

    10 button to turn the device on and off. 11 [dmx] button to switch between dmx and stand-alone mode. 12 [slave] button to switch between master and slave mode. 13 [auto 1], [auto 2], [speed] buttons to activate automatic mode 1 or 2 and to adjust the program's speed. 14 [up], [down] buttons to switc...

  • Page 30

    16 [strobe] button to turn the strobe effect on/off. 17 numerical buttons 0 … 9 for direct number entry. 18 [sound 1], [sound 2] buttons to activate automatic mode 1 or 2 of the sound control. Connections and operating elements 30 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 31: Operating

    7 operating 7.1 starting the device using the main switch, turn the device on. After a few seconds, the fan starts. The display shows the current operation mode. 7.2 operating controls on the unit press [menu], [up] or [down] repeatedly until the display shows ‘addr’ . Confirm with [enter]. Now you ...

  • Page 32

    Use [up] and [down] to select the desired mode ‘sou1’ or ‘sou2’ . Confirm with [enter]. Now you can adjust the sensitivity of the built-in microphone for sound control. Use [up] and [down] to select a value between 0 (low sensitivity) and 9 (high sensitivity), display shows ‘se0’ … ‘se9’ . Press [me...

  • Page 33

    Press [menu], [up] or [down] repeatedly until the display shows ‘auto’ . Confirm with [enter]. Use [up] and [down] to select the desired mode ‘aut1’ , ‘aut2’ or ‘aut3’ . Confirm with [enter]. You can now set the program's speed between ‘sp 1’ and ‘sp 9’ . Press [menu], [up] or [down] repeatedly unti...

  • Page 34

    N ‘1ch’ (one channel) n ‘5ch’ (five channels) n ‘7ch’ (seven channels) n ‘8ch’ (eight channels) confirm by pressing [enter]. Press [menu], [up] or [down] repeatedly until the display shows ‘chnd’ . Confirm with [enter]. Now use [up] or [down] to select one of the following dmx operating modes: n ‘1c...

  • Page 35

    7.3 operating via ir remote control press [menu], [up] or [down] repeatedly until the display shows ‘reno’ . Confirm with [enter]. Use [up] and [down] to select the option ‘on’ to operate the unit via the ir remote control. Confirm with [enter]. Operating bat.Par 6 rgbwa bat.Par 6 rgbuv 35 led spotl...

  • Page 36

    7.4 menu overview bat.Par 6 rgbwa (item no. 385435) operating 36 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 37

    Bat.Par 6 rgbuv (item no. 385457) operating bat.Par 6 rgbwa bat.Par 6 rgbuv 37 led spotlight.

  • Page 38

    7.5 functions in 1-channel dmx mode channel value function 1 0…255 select colour macros 1 … 51 7.6 functions in 4-channel dmx mode channel value function 1 0…255 intensity red (0 % to 100 %) 2 0…255 intensity green (0 % to 100 %) 3 0…255 intensity blue (0 % to 100 %) 4 0…255 intensity uv light (0 % ...

  • Page 39

    7.7 functions in 5-channel dmx mode channel value function 1 0…255 intensity red (0 % to 100 %) 2 0…255 intensity green (0 % to 100 %) 3 0…255 intensity blue (0 % to 100 %) 4 0…255 intensity white (0 % to 100 %) 5 0…255 intensity amber (0 % to 100 %) bat.Par 6 rgbwa (item no. 385435) operating bat.P...

  • Page 40

    7.8 functions in 6-channel dmx mode channel value function 1 0…255 master dimmer (0 % to 100 %) 2 0…255 intensity red (0 % to 100 %) 3 0…255 intensity green (0 % to 100 %) 4 0…255 intensity blue (0 % to 100 %) 5 0…255 intensity uv light (0 % to 100 %) 6 0…255 stroboscope effect (0 % to 100 %) bat.Pa...

  • Page 41

    7.9 functions in 7-channel dmx mode channel value function 1 0…255 master dimmer (0 % to 100 %) 2 0…255 intensity red (0 % to 100 %) 3 0…255 intensity green (0 % to 100 %) 4 0…255 intensity blue (0 % to 100 %) 5 0…255 intensity white (0 % to 100 %) 6 0…255 intensity amber (0 % to 100 %) 7 0…255 stro...

  • Page 42

    Channel value function 1 0…255 master dimmer (0 % to 100 %) 2 0…255 intensity red (0 % to 100 %) 3 0…255 intensity green (0 % to 100 %) 4 0…255 intensity blue (0 % to 100 %) 5 0…255 intensity uv light (0 % to 100 %) 6 0…15 no function 16…31 programme 1 32…47 programme 2 48…63 programme 3 64…79 progr...

  • Page 43

    Channel value function 96…111 programme 6 112…127 programme 7 128…143 programme 8 144…159 programme 9 160…175 programme 10 176…191 programme 11 192…207 programme 12 208…223 programme 13 224…239 sound mode 1 240…255 sound mode 2 7 0…255 stroboscope effect (0 % to 100 %), if channel 6 = 0…15 program s...

  • Page 44

    7.10 functions in 8-channel dmx mode channel value function 1 0…255 master dimmer (0 % to 100 %) 2 0…255 intensity red (0 % to 100 %) 3 0…255 intensity green (0 % to 100 %) 4 0…255 intensity blue (0 % to 100 %) 5 0…255 intensity white (0 % to 100 %) 6 0…255 intensity amber (0 % to 100 %) 7 0…15 no f...

  • Page 45

    Channel value function 64…79 programme 4 80…95 programme 5 96…111 programme 6 112…127 programme 7 128…143 programme 8 144…159 programme 9 160…175 programme 10 176…191 programme 11 192…207 programme 12 208…223 programme 13 224…239 sound mode 1 240…255 sound mode 2 8 0…255 stroboscope effect (0 % to 1...

  • Page 46

    Channel value function program speed, if channel 6 = 16…223 microphone sensitivity, if channel 6 = 224…255 operating 46 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 47: Technical Specifications

    8 technical specifications technical specifications bat.Par 6 rgbwa bat.Par 6 rgbuv 47 led spotlight.

  • Page 48

    Bat.Par 6 rgbwa (item no. 385435) bat.Par 6 rgbuv (item no. 385457) leds 6 × rgbwa, each 8 w 6 × rgbuv, each 8 w number of dmx channels 1, 5, 7, 8 1, 4, 6, 7 dispersion angle 25 ° operating voltage supply 100 – 240 v 50/60 hz replaceable battery pack, item no. 385488 (lithium-ion battery, 10.8 v, 15...

  • Page 49

    Bat.Par 6 rgbwa (item no. 385435) bat.Par 6 rgbuv (item no. 385457) dimensions (w × h × d) 250 mm × 254 mm × 130 mm weight 2 kg technical specifications bat.Par 6 rgbwa bat.Par 6 rgbuv 49 led spotlight.

  • Page 50

    9 plug and connection assignments this chapter will help you select the right cables and plugs to connect your valuable equip- ment so that a perfect light experience is guaranteed. Please take our tips, because especially in ‘sound & light’ caution is indicated: even if a plug fits into a socket, t...

  • Page 51: Troubleshooting

    10 troubleshooting notice! Possible data transmission errors for error-free operation make use of dedicated dmx cables and do not use ordi- nary microphone cables. Never connect the dmx input or output to audio devices such as mixers or ampli- fiers. In the following we list a few common problems th...

  • Page 52

    Symptom remedy device not working, no light check the mains connection and the main fuse. Not responding to dmx controller 1. Check the dmx connectors and cables to see if they are properly linked. 2. Check the address settings and the dmx polarity. 3. Try using another dmx controller. 4. Check whet...

  • Page 53: Cleaning

    11 cleaning clean the optical lenses, that are accessible from the outside, regularly in order to optimize the light output. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device. ...

  • Page 54: Protecting The Environment

    12 protecting the environment for the packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. Are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure th...

  • Page 55

    This product is subject to the european waste electrical and electronic equipment directive (weee) in its currently valid version. Do not dispose with your normal household waste. Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the...

  • Page 56

    Notes 56 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 57

    Notes bat.Par 6 rgbwa bat.Par 6 rgbuv 57 led spotlight.

  • Page 58

    Notes 58 bat.Par 6 rgbwa bat.Par 6 rgbuv led spotlight.

  • Page 60

    Musikhaus thomann · hans-thomann-straße 1 · 96138 burgebrach · germany · www.Thomann.De.