Varytec Prestige II User Manual

Summary of Prestige II

  • Page 1

    User manual progression ii.

  • Page 2

    2 / 10 table of contents 1. Safety instructions ............................................................................................................................ 3 1.1. For safe and efficient operation ............................................................................ 3 2. Techn...

  • Page 3

    3 / 10 1. Safety instructions • this device is suitable for indoor use only. • all modifications to the device will void the warranty. • repairs are to carry out by skilled personnel only. • use only fuses of the same type and original parts as spare parts. • protect the unit from rain and humidity ...

  • Page 4

    4 / 10 important: damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems. Make sure the electrical connection is carried out by qualified personnel. All electrical and mechanical connections have to ...

  • Page 5

    5 / 10 3 0 1 – 255 strobe off strobe slow to fast 4 0 – 15 16 – 255 shutter closed shutter open if you use cables longer then 100m you should put in a terminator at the last item in your daisy chain! Use dmx cables with a 120ohms shield only! All plugs should use xlr connectors! The connectors confi...

  • Page 6

    6 / 10 addr 001 512 slnd nast sl 1 5l 2 soun on off sens 1 100 blnd yes no led on off disp disp dsip fhrs ver 4. Control of the menu 4.1. Menu structure dmx 512 address setting master mode slave mode normal slave mode lightshow sound to light on sound to light off sound to light sensitivity blackout...

  • Page 7

    7 / 10 4.2. Description of the menu addr dmx address setting 1. Push the up/down buttons until the display shows addr. 2. Push enter 3. 1 appears in the display blinking. With the up/down buttons you can no adjust the dmx address from 1 to 512 4. Push enter to confirm slnd master slave settings 1. P...

  • Page 8

    8 / 10 disp inversion of the display 1. Push the up/down buttons until the display shows disp. 2. Push enter 3. Use the up/down buttons to choose from disp and dsip, in this case dsip means the display is inverted and turned 180° 4. Push enter to confirm fhrs zeigt die laufzeit des gerätes an 1. Pus...

  • Page 9

    9 / 10 7. Technical data voltage: 100v ~ 240v 50/60hz power consumption: 22,5w max. Fuse: 1a (120 & 230v) lightsource: 1 x led 10 watt rgbw beam angle: 65° weight: 3,8kg measures: 200 x 297 x 320mm modes: dmx (4ch) automatic mode sound to light mode master slave mode 7.1. Power daisy chain at this i...

  • Page 10: B & K Braun Gmbh

    10 / 10 importer: b & k braun gmbh industriestraße 1 d-76307 karlsbad www.Bkbraun.Com info@bkbraun.Com.